PD Calibrators
-
Product
Positive Displacement (PD) Meters
-
Positive Displacement (PD) flow meters are volumetric flow measurement instruments ideal for low flow rates, highly viscous fluids, and measurement of flows involving starts and stops or pulsing. Positive displacement flow meters are similar in design to the gear pump. The principle of operation is reversed however; instead of the gears driving the fluid, the fluid drives the gears. A non-intrusive hall-effect sensor detects the movement of the gear and as each gear tooth passes the sensor, a square wave pulse is produced and a discrete volume of liquid is measured. The resulting pulse train is proportional to the actual flow rate and provides a highly accurate representation of the fluid flow.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Broadband Calibrated Noise Sources
-
Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.
-
Product
Acoustic Calibration
-
Trescal provides full Acoustic Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Acoustic Calibration services can be delivered at your site or at our lab. Accreditations for our acoustic calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Hardness Calibration
-
Trescal provides full Hardness Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Hardness Calibration services can be delivered at your site or at our lab. Accreditations for our hardness calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
-
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
Product
IR To USB PC Connectivity Cable For Handheld LCR/Capacitance/Multifunction Calibrator Meter
U5481B
Digital Cable
Connect easily to your PC from a handheld LCR meter or capacitance for faster data logging
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Spectral Irradiance / Illuminance Calibration Standards
-
Standard lamps calibrated in illuminance and spectral irradiance. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
CALIBRATOR Multi Function Calibrator
MC140
-
The Multifunction Calibrator MC140 functions as a Voltage Calibrator, Current Calibrator, Power Calibrator, Resistance Calibrator, Capacitance Calibrator and a Thermocouple Calibrator.? Having very low uncertainties, it is ideal as a standard of these electric quantities in calibration laboratories.
-
Product
Bench Digital Multimeter, Calibrated D & U, 1 kV, 10 A, 3.8 Digit
72-1015 CAL DU
-
The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
Product
Portable Trace-Level O3 Calibrator
Model T753U
-
Teledyne Advanced Pollution Instrumentation
The Model T753U is a portable, microprocessor based precision Calibrator for Ozone gas instruments and sensors. Using a sophisticated Ozone generation system, combined with a sensitive photometer and pneumatic design, the T753U produces stable and reliable concentrations of Ozone in a convenient and rugged package based on our popular T750U Portable Multigas Calibrator platform. The T753U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field for virtually any application. An internal zero air option extends the T753U's capabilities to also provide a clean and dry source of zero air, eliminating the need for a separate source of zero air. The internal zero air source module contains a software driven electronic inlet valve manifold allowing the calibrator to automatically switch between internal and external zero air sources depending on the application needs.
-
Product
Calibration Kit
N912
-
*N912 Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
Product
Calibrators
-
Our high accuracy calibrators work with all competitor products and offers the customer a way to maintain their equipment, while keeping the specifications of their process.
-
Product
MP field sources calibration set
-
The MP field source calibration set is used to measure electric or magnetic fields in a frequency range up to 3 GHz. RF fields or transient fields can be measured. The MP field source calibration set is used to check fields of the Langer EMV-Technik GmbH field sources, fields of TEM cells and IC striplines.
-
Product
Multiport Calibration Assistant
S96552B
-
The S96552B provides a tool to flexibly create and manage calibration sets for multiport measurements. For example, two calibration sets with independent test ports can be combined as one calibration set with a greater number of test ports. The software also offers a way to re-calibrate using a certain set of test ports to refresh the calibration set.
-
Product
Calibration Test Benches
-
Nagman Instruments & Electronics Pvt. Ltd
Nagman’s wide range of Calibration Systems – Test Benches, Workstations, Bench-tops & Mobile Units – are designed & executed to serve as Powerful tools for Total Quality Management & ISO Conformance with Accuracies Traceable to International Standards and Total Solution to all Calibration requirements.
-
Product
Calibration Hand Pumps
-
Nagman Instruments & Electronics Pvt. Ltd
Calibration hand pumps are the most cost-effective way to calibrate pressure devices. At Nagman, you can find Calibration hand pumps that are the best in the industry. Calibration hand pumps are used to generate pressure. Which can be hydraulic, pneumatic, or vacuum. This kind of pressure generation is done during testing and calibration applications. We also offer calibration pumps that can help in high pressure to low pressure calibrations. Visit Nagman website and browse through the range of calibration hand pumps to find the right device for your calibration needs.
-
Product
ECU Calibration
-
Designing an Electronic Control Unit (ECU) is only the beginning. The features in ECUs, such as Powertrain Control Units, are quickly becoming more complex and offering more features. Thousands of variables are now provided for the engineer to modify during the in-vehicle calibration phase, and fine tuning them is as complicated as it is critical. Calibration tools significantly impact the efficiency and effectiveness of the ECU development process. These tools are typically comprised of PC-based software to perform the adjustment of the variables and an ECU hardware interface to provide the connection of the software to the controller. Teams must be able to measure and time-align relationships of inputs and outputs and make real-time modifications.
-
Product
3.5mm Short Open Load Thru 4-in-1 Analyzer Calibration Kit
-
Fairview Microwave’s portable calibration kits consist of two models, both with a compact, lightweight, 4-in-1 design package. These short-open-load-through (SOLT) calibration kits feature precision 3.5mm connectors, have a 26.5 GHz calibration capability, gold plated short-open-load-thru and include a handy lanyard. These SOLT calibration kits have a phase deviation of +/-2 degrees maximum and return loss of 30 dB minimum and feature an impedance level of 50 Ohms nominal. They are ideal for telecommunications, military electronics, automotive, medical, aerospace and consumer electronics industries.
-
Product
Trace-Level Dilution Calibrator
Model T700U
-
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
Product
HiPot Calibrator
Model 9102
-
The 9102 Hipot Calibrators is specially designed standard devices for instrument calibration lab. The 9102 can simulate multiple loads and apply to various Hipot testers. These calibration equipment can save manufacturers a great deal of regular calibration fee.
-
Product
Instrumentation Calibration Services
-
We offer a range of instrumentation calibration services for Kemo products in addition to other signal conditioning and sensors. We have many decades of experience in the manufacture, test and calibration of our instruments and those of our competitors. Please refer to the list below for an example of our calibration options, all equipment used within our calibration department is calibrated and traceable to a UKAS accredited National standard:
-
Product
Decade Box, Calibrated, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL
-
The 72-7265 CAL from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Calibrated Diffuse Reflectance Standards
-
Diffuse reflection calibration standards in synthetic ODM and ODMP material
-
Product
Calibrated Solar Reference Cell
-
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
Product
Portable Calibration Shaker Table
AT-2030
-
The AT-2030 portable calibration shaker table is designed for simple accelerometer and vibration transducer calibration without the need for advanced features. AT-2030 shaker table and vibration calibrator is a variable frequency, variable amplitude, battery operated portable shaker capable of calibrating accelerometers, transducers, and proximity probes. Applications are producing a known vibration signal in g’s, mils, or ips for sensor, wiring, instrumentation, and system checkout in vibration condition monitoring applications.
-
Product
PDS Cutter Dredger Monitoring Software
-
TELEDYNE PDS for Cutter Dredges is designed to the requirements of the dredge operator to carry out their job more efficiently. The operator has a real time overview of the dredger with the top and side views displaying the vessel outline, ladder, and cutter head along with the surveyed depths, design, and dredged depth.