MUX
Combine multiple signals into one signal.
-
Product
Dual 2 Channel Fibre Optic Mux SC/PC
40-815-222
Fiber Optic Switch
Pickering PXI Fiber Optic Multiplexers connect a single channel to one of two or four channels. They are available in single or dual multiplexer configurations supporting single-mode or multi-mode fiber. A wide choice of connectors types is available. The 40-810 multiplexer connects the optical channel by redirecting the optical signal into a selected output fiber.
-
Product
PXI/PXIe RF Multiplexer, Quad 4-Channel, 3GHz, 75Ω, SMB
42-832A-004
Multiplexer Module
The 40-832A-004 (PXI) and 42-832A-004 (PXIe) are 75 Ohm 4 to 1 RF multiplexers with 4 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
PXI MUX 1 Bank of 64 Channel 2 Pole
40-610-022-1/64/2
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI Single 16 to 1 RF MUX SMB 75 Ohm
40-835-001
Multiplexer Module
The 40-835-011 is a single 75 Ohm 16-channel RF MUX in a single PXI slot. The module has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The design of the 40-835 minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
Product
PXI High Density MUX BRIC, 5-Chan, 160-Pole
40-570-015
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
PXI 2 Amp Multiplexer, Quad 16-Channel, 1-Pole
40-635A-008
Multiplexer Module
The 40-635A-008 is a quad 16-channel, 1-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI Single SP6T MUX 6GHz 50Ω SMA
40-784-001
Multiplexer Module
Pickering Interfaces’ 40-784 PXI Microwave Multiplexer Modules have a characteristic impedance of 50 Ohm and are capable of switching signals up to 40GHz. Available in single or dual SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI MUX 8 Banks of 8 Channel Screened 1 Pole
40-610-021-S-8/8/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber
40-852A-118-M62.5-HI
Multiplexer Module
The 40/42-852A-118-M62.5-HI is a PXI/PXIe 8-channel multiplexer with FC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PCI 2 Amp Multiplexer, Single 4-Channel, 8-Pole
50-635A-104
Multiplexer Module
The 50-635A-104 is a single 4-channel, 8-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Single-Mode
40-850A-514
Multiplexer Module
The 40/42-850A-514 is a PXI/PXIe 4-channel multiplexer with ST connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI 20 Banks of 4 Channel 2 Pole MUX
40-615-022-20/4/2
Multiplexer Module
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 50/125 Fiber, FC/APC Connectors, With Interlock
42-850A-014-M50-HI
Multiplexer Module
The 40/42-850A-014-M50-HI is a PXI/PXIe 4-channel multiplexer with FC/APC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI Very High Density Multiplexer, 10-Channel, 16-Pole
40-675A-002-10/16
Multiplexer Module
The 40-675A-002-10/16 is a 10-channel, 16-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, 3GHz, 75Ω, SMB
40-832A-002
Multiplexer Module
The 40-832A-002 (PXI) and 42-832A-002 (PXIe) are 75 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
PXI High Density Screened Mux 49 Ch 2 Pole
40-670A-021-S-49/2
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected.In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI/PXIe RF Multiplexer, Single 16-Channel, 3GHz, 75Ω, SMB
40-835A-001
Multiplexer Module
The 40-835A-001 (PXI) and 42-835A-001 (PXIe) are single 75 Ohm 16-channel RF multiplexers in a single slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The design of the 40/42-835A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
Product
PXI 2 Amp MUX, Single 8-Channel 8-Pole
40-635-004
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, 3GHz, 75Ω, MCX
42-832A-102
Multiplexer Module
The 40-832A-102 (PXI) and 42-832A-102 (PXIe) are 75 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
PCI Very High Density Multiplexer, 99-Channel, 2-Pole
50-670C-022-99/2
Multiplexer Module
The 50-670C-022-99/2 is a 99-channel, 2-pole MUX and is part of a series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
LXI 144-Channel 1GHz Video Multiplexer
60-721A-006
Multiplexer Module
The 60-721A High Performance Video MUX is designed for the switching of RF signals in 75 Ohm systems at frequencies up to 1GHz. It is ideal for 75 Ohm monitoring applications that require a multiplexer to select one channel to be routed to measuring equipment.
-
Product
PXI High Density MUX BRIC, 48-Chan, 20-Pole
40-570-316
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
PXI High Density MUX BRIC, 48-Chan, 10-Pole
40-570-413
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
PXI 3A Power MUX BRIC, 24-Channel, 6-Pole
40-571-403
Multiplexer Module
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXI/PXIe MEMS Optical MUX, Dual 2-Channel, Single-Mode
40-855A-322
Multiplexer Module
The 40/42-855A-322 is a PXI/PXIe dual 2-channel multiplexer with MU connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Single-Mode, 9/125 Fiber, LC Connectors
42-850A-414
Multiplexer Module
The 40/42-850A-414 is a PXI/PXIe 4-channel multiplexer with LC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber
40-852A-118-M50-HI
Multiplexer Module
The 40/42-852A-118-M50 is a PXI/PXIe 8-channel multiplexer with FC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI 2 Amp MUX, Single 8-Channel 4-Pole
40-635-103
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber, ST Connectors
42-852A-518-M62.5
Multiplexer Module
The 40/42-852A-518-M62.5 is a PXI/PXIe 8-channel multiplexer with ST connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI High Density MUX BRIC, 4-Chan, 40-Pole
40-570-211
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.


























