Ground Leakage
is unwanted current flowing to ground.
-
Product
Electrical Safety Multi-Analyzer
TOS9300 Series
-
The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
Product
Electrical Safety Analyzer
19032
-
Chroma Systems Solutions, Inc.
Our Electrical Safety Analyzers combine Hipot, Insulation Resistance ( IR), Ground Bond (GB), Leakage Current (LC)/AC LC/DC LC, and Dynamic Function Tests. Savings can be up to 50% of production line space by not having to purchase and rack several safety test instruments. It also increases efficiencies of electrical safety testing and reduces associated labor costs.
-
Product
Hipot Line Testers
-
The newest product of our Hipot Line Testers, the UL Listed HT-S series hipot now comes with an adjustable ground continuity test in range of 0.08 - 1.50 , and Auto-offset for test leads up to 1.00 . Performs 0-2000 AC Hipot Test. Neutral/Hot to Ground Leakage current test up to 20 mA AC. Easy to use and connect. Ships complete with cables, manual, and a Calibration Certificate.
-
Product
Electrical Safety Testers
-
A high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
Product
Iron Core Earth Tester
-
Weshine Electric Manufacturing Co., Ltd
Transformer iron core grounding current tester is a high-precision clamp meter specially designed for measuring AC leakage current, current and voltage. Large diameter (80×80mm) can clamp φ80mm cable, or 96mm×4mm flat steel ground wire, suitable for cables Leakage detection and transformer grounding flat steel leakage measurement.
-
Product
Ground-Fault Detectors for Ungrounded Systems
-
Early detection of ground faults on ungrounded systems allows critical systems to remain online while faults are identified and resolved. By continuously monitoring the system's insulation resistance, Bender's ground-fault detectors can provide early indication of both immediate and trending ground faults before leakage current may be of concern.
-
Product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
-
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
Product
Microwave Leakage Detector
-
*Microwave leakage detection:≥ 1mw/cm2*Meter points to show "SAFETY" or "DANGER" zone*No battery required*Dimension (LxWxD) mm : 53x36x23*Packaging: Sliding blister card
-
Product
Leakage Current Tester and Clamp-On Earth / Ground Resistance Tester
-
10µA Ultra High ResolutionLarge Conductor Diameter (30mm)AC Current in 5 Ranges (40mA, 400mA, 4A, 40A, 60A)Wide Frequency Response (40Hz-1KHz)ACA, ACV, Ω and ContinuityLarge 3¾ Digit LCD (4000 Count)40 Segment Fast Bargraph Display (20 times/sec.)Data Hold and Max / Min HoldRelative Measurement600 Vrms Overload Protection in Resistance Range
-
Product
Medical Leakage Tester
GLP2-CE
-
For testing the leakage current of medical equipment to standards EN 60990 + EN 60601.
-
Product
Grounding Series
-
Weshine Electric Manufacturing Co., Ltd
It is widely used in measuring ground resistance of electric power, telecommunication, meteorology, construction, lightning protection and industrial electrical equipment.
-
Product
Leakage Current Testing
-
Educated Design & Development, Inc.
Fast - All operator controls are located on the front panel to expedite testing. The entire test can be performed in a matter of seconds! Pays for itself in time and stress savings. Versatile - Measures Leakage Current in accordance with UL, CSA, EN, and IEC/ International Standards. Includes ability to perform open neutral, open ground, and line polarity forward/reverse test conditions. Adaptable - Universal rear panel receptacle allows for testing products with any plug configuration. Accurate - True RMS meter accurately measures both sinusoidal and non-sinusoidal waveshapes. This is important when testing products using a switch mode power supply which can generate non-sinusoidal leakage currents. Calibrated, traceable to NIST. Flexible - A front panel switch permits testing either through the power cord of the product under test, from surface/ patient connection-to-ground, or from surface/ patient connection-to-surface/ patient connection. Portable - Lightweight, with integral handle. Other Features - Product Ground Switching (grounding conductor maintained to device under test when not measuring leakage). Automatic front receptacle disconnect when configured in the 240V test mode (prevents inadvertent connection of 120V when configured for 240V operation). Proven - These are the only leakage current testers designed and supported by Product Safety experts. That is part of the reason why they have become the standard in the industry. Full technical support by experienced safety engineers.
-
Product
Leakage Current Monitor
-
To alert utility-line workers of overcurrent conditions on such aerial devices as insulated ladders and truck booms, the Chance Sentinel sounds an alarm if leakage current reaches a pre-set level.
-
Product
Earth Ground Tester
1625-2
-
The Fluke 1625-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes.
-
Product
Leakage Current Measurement
CX-2675C3
-
Shenzhen Chuangxin Instruments Co., Ltd.
Leakage Current Measurement Output voltage:0~250V (AC/DC)
-
Product
Ground Penetrating Radar
-
RD1100 and RD1500 both feature internal GPS and high resolution touch screens. For connectivity, both offer on-board Wi-Fi and a USB port. Additionally, the RD1500 allows users to create depth slices and review their locate path on screen while on site, and selectively enhance shallow/small, medium depth/size, or deep/large targets using the proprietary FrequenSee™.
-
Product
Ground Resistance Tester
2521
-
Shenzhen Chuangxin Instruments Co., Ltd.
High measuring accuracy, high speed, easy to use, especially suitable for using in laboratory and automatic testing line. Test current AC / 5 ~ 30 (a), resistance Ω (0 ~ 600 m), time (1 ~ 99 s) shows at the same time. Test time can be arbitrary setted. Test alarm value can be arbitrary set up. Pass/fail sound and light alarm.
-
Product
Leakage Clamp Meters
3920 CL
-
Standard Electric Works Co., Ltd
● Designed for testing AC current and AC voltage. ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Low battery indication.
-
Product
Cylinder Leakage Tester Kit
CLT200
-
Quickly locates internal engine problems such as bad rings, valves and leaking head gaskets. Dual 2-1/2" heavy duty gauges with protective outer boots. Scales read 0-100psi and 0-700 kg/cm2Pressure regulated manifold includes high quality quick couplers for fast set-ups.
-
Product
Battery Ground Detector
BGD
-
Battery Ground Detectors supply contact closures for alarm indications at precise ground fault resistance settings.
-
Product
Wet Leakage Current Test
-
King Design Industrial Co., Ltd.
The outdoor solar module will endure the erosion of rain, fog, snow and sandstorm. To make sure that solar module will not wet leakage current accident and tolerate huge load pressure in such harsh conditions, we adopt wet leakage current to simulate the above weather conditions.
-
Product
Ground Weather Analytics
HELIOS
-
L3Harris Geospatial Solutions, Inc
Microclimates are on the rise, and as a result, there are extreme deviations of wind, snow, fog and visibility even over short distances. Organizations of all sizes need hyperlocal ground information and weather data to enhance operational efficiencies and make better decisions that can save time, money, property and even lives.
-
Product
Ultrasound Leakage Tester
-
Measures both the conductivity of the cleaning medium and the leakage current of the ultrasound transducer.
-
Product
Ground Grid Tester
GGT Series
-
The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.
-
Product
Leakage Test
-
Leakage current and discharge current depend on the insulation of the device. The measurement simulates various fault situations that could occur during operation. The test determines whether the measured current is within the permissible limits and poses no danger to the user in case of a fault.
-
Product
Earth Ground Testers
-
Fluke''s family of earth ground testers have been built to address the entire spectrum of ground testing methods from the basic to the most advanced. Our testers have been designed to be accurate, safe and easy to use. We provide quick and precise resistance measurements through several test methods: 3- and 4-pole Fall-of-Potential testing, selective testing, stakeless testing and 2-pole testing. Detailed application information can be found at the Earth Ground Solution Center.
-
Product
Leakage Current Tester
-
Test Voltage : - 1V to 500V DC settableAccuracy : ± 1% of set Value ± 1digitLeakage Current : - Accuracy - ± 0.5% ± 1digitDigital Model – 19.99μA / 199.9 μA / 1.999mA / 19.99mAAnalog Model - 10μA /25μA/100 μA/1mA/2.5mA/10mASeparate Indication for Charge / Measure and Discharge modeAvailable in Digital Version Also
-
Product
Leakage Clamp Meters
3921 CL
-
Standard Electric Works Co., Ltd
● Designed for testing AC current and AC voltage. ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication.





























