Waveform Signal Generators
See Also: Waveform Generators, Arbitrary Waveform Generators
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4D
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Arbitrary Function Generator
HMF2525/HMF2550
Powerful pulse generator Provides pulses with a recurrence rate of up to 12.5 MHz/25 MHz; the pulse width can be set from 15 ns to 999 s with a resolution of 5 ns. Rise/fall time can be selected from 8 ns to 500 ns – a very useful feature when characterizing input hysteresis of semiconductor devices Easily create arbitrary waveforms Arbitrary waveforms can be developed with PC software. Stored waveforms can be loaded via front USB port or imported via the complimentary HMExplorer software (available for download)
-
product
PXIe-5665, Up to 14 GHz PXI Vector Signal Analyzer
781426-03
Up to 14 GHz PXI Vector Signal Analyzer - The PXIe‑5665 is a modular, three‑stage superheterodyne analyzer that you can use as either a spectrum analyzer or vector signal analyzer. It supports RF list mode, which increases multiband measurement speed with fast and deterministic changes in configuration. In addition, you can use the PXIe‑5665 with the Modulation Toolkit to analyze custom and standard modulation formats. The PXIe‑5665 can perform measurements for a broad range of communications standards such as GSM, EDGE, WCDMA, WiMAX, LTE, Bluetooth, WLAN, DVB‑C/H/T, ATSC, and MediaFLO. Because all measurements are software defined, you can reconfigure the measurements using standard-specific toolkits. With these toolkits, the PXIe‑5665 provides a low-cost solution to high-performance RF measurements.
-
product
PXI/PXIe High Resolution Waveform Digitizer Family
PXD(e)721x
The PXD(e)721x High Resolution Digitizer- Family features up to two 100MS/s simultaneously sampled input channels with 16 Bit resolution, input voltages up to ±60V and a bandwidth of 50MHz (100MHz with option DBW).Every digitizer channel has its own 2MB memory which allows up to 1 million samples. Depending on the amount of channels and the isolated option, the digitizers are built into a compact 3U PXI device for 1 or 2 slots. All isolated devices have a high common mode rejection ratio (CMRR). A great number of trigger capabilities results in multiple instrument and channel synchronization possibilities.Data can be acquired before and after the trigger event with a programmable sample counter, that controls the number of data points.
-
product
Standard 0.50 (14.00) - 2.00 (57.00) Non Replaceable General Purpose Probe
A-A-S-R
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm
-
product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1V1S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Alternate 2.50 (71.00) - 5.80 (164.00) General Purpose Probe
P2665G-1R2S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
PSG RF Analog Signal Generator, 100 kHz to 9 GHz
E8663D
Tackle demanding radar & satcom measurements with metrology-grade performance, including high output power & superior level accuracyUse as an ideal reference in phase noise test systems or for analog-to-digital converter testing with the lowest phase noise in a commercial sourceCharacterize devices & circuits by adding AM, FM, M & pulse modulation to your signalImprove existing test system performance: E8663D is built on the outstanding legacy of the 8663A & is fully code compatible
-
product
Alternate 2.54 (72.00) - 6.20 (176.00) General Purpose Probe
HPA-52T-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2P-1
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Signal, Contact, ITA, QuadraPaddle, 5 Amp, .025" Round Post
610138115
Primary mating contact 610138200. (May mate with other Receiver contacts, as well.)Available in twin-female, crimp/solder, twin male, and wire-wrap design, QuadraPaddle contacts are engineered for flexible interconnect options. Rated at 5 amps continuous (1250 VAC) with a 2 ounce insertion force, QuadraPaddle contacts provide 4 reliable points of contact per pin, outstanding electrical performance, and low mating force.Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body (RCV) – BeCu (Twin Female)BeCu/PhBrz (Crimp)Male (ITA) – BrassContact Plating Female (RCV) – 50µ” Au over 100µ” NiMale (ITA) – 30µ” Au over 100µ” NiCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 0.24
-
product
Ethernet/LXI generatorNETBOX 16 Bit Arbitrary Waveform Generator - up to 125 MS/s on 8 Channels, up to 80 MS/s on 16 Channels
DN2.656-16
The generatorNETBOX DN2.65x arbitrary waveform generators (AWG) is a general purpose multi-channel AWG with outstanding dynamic performance. The series includes LXI units with either four, eight or 16 synchronous channels. The large onboard memory can be segmented to replay different waveform sequences.
-
product
Radius, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0D-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
Signal, Patchcord, Receiver, 72", TriPaddle, 22 AWG, Single Ended ( 5 Amps)
7-104922000-072
Signal, Patchcord, Receiver, 72", TriPaddle, 22 AWG, Single Ended ( 5 Amps).
-
product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-8
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3C
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5E
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
product
Standard 0.70 (20.00) - 1.30 (37.00) Non Replaceable General Purpose Probe
A-S-V
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
product
Arbitrary Waveform Transceivers
Proteus Series
Tabor’s Proteus Arbitrary Waveform Transceiver enables you to transmit, receive and perform digital signal processing all in a single instrument. The Proteus AWT is a valuable tool for R&D labs in growing markets such as quantum physics, medicine, aerospace and defense, telecommunications and automotive. For synchronized, phase coherent, multi-channel applications such as quantum physics and radar applications the Proteus arbitrary waveform transceiver is an ideal, space efficient and cost effective solution.
-
product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1V2S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Astronics PXIe-1209 , 2-Channel, 100 MHz PXI Pulse Generator
785033-01
2-Channel, 100 MHz PXI Pulse Generator - The Astronics PXIe-1209 provides dual independent pulse generation with full control of all timing parameters with extremely high resolution. Both channels are fully independent, and you can configure pulse delay, double pulse spacing, pulse width, and period. Each channel offers front panel trigger inputs with software-programmable thresholds and PXI backplane triggering.
-
product
Signal, Contact, Receiver, QuadraPaddle, 5 Amp, Male Adapter, .025" Round Post (Adapter Pin)
610138117
Primary mating contact 610138100. (May mate with other Twin Female contacts, as well.)Specifications Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body BrassContact Plating 30µ” Au over 100µ” NiCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 0.24
-
product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30U
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
product
PXIe-5450, 145 MHz Bandwidth, 16-Bit, 128 MB, I/Q PXI Waveform Generator
780419-01
PXIe, 145 MHz Bandwidth, 16-Bit, 128 MB, I/Q PXI Waveform Generator—The PXIe‑5450 is a 145 MHz, dual‐channel arbitrary waveform generator optimized for I/Q communications signals. It is an ideal instrument for testing devices with I/Q inputs, or as the baseband component of an RF vector signal generator. The PXIe‑5450 also features onboard signal processing (OSP) functions that include pulse shaping and interpolation filters, gain and offset control, and a numerically controlled oscillator (NCO) for frequency shifting. The PXIe‑5450 also features advanced synchronization and data streaming capabilities.
-
product
Patchcord, Signal, Receiver, 72", QuadraPaddle Insert, Single Ended
7-152924000-072
Patchcord, Signal, Receiver, 72", QuadraPaddle Insert, Single Ended
-
product
Ultra High 4.18 (119.00) 11.70 (332.00) General Purpose Probe
EPA-3F-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20B
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
product
9GS/s 8 Bit, 4GS Mem 4CH 16 Markers AWG
P9084B
The Proteus P9084B, is a 9GS/s, four channel arbitrary waveform generator packaged in a 4U, 19” standalone box with a 9” touch screen and on board PC , offering technologically advanced options and configurations that integrate the ability to transmit, receive and perform digital signal processing all in a single instrument. The P9084B offers industry leading performance Including an innovative task oriented programming, real time data streaming, fast feedback loop for environment dependent waveform generation and user customizable FPGA for application specific solutions.
-
product
Signal Generator Adapter Module For FlexRIO
Signal Generator Adapter Modules for FlexRIO feature either high or low‐speed analog output and can be paired with a PXI FPGA Module for FlexRIO or the Controller for FlexRIO for custom signal generation. Whether you need to dynamically generate waveforms on the FPGA or stream them across the PXI backplane, these adapter modules are well suited for applications in communications, hardware‐in‐the‐loop (HIL) test, and scientific instrumentation.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2E
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64





























