Platinum
See Also: Precious Metal, Gold, Platinum RTD
-
Product
High-Precision Thermometer
-
The high-precision thermometers from Anton Paar are designed for the most accurate temperature measurements, comparison calibrations and fixed point calibrations in industry, laboratories and research. Combined with calibrated platinum resistance thermometers, Anton Paar's thermometers achieve a measuring uncertainty of 10 mK or less.
-
Product
Gold Purity Tester
PRO‑ALLOY
-
The Easy Way To Test Gold & Platinum Jewelry. Measure the purity of rings, chains, watches and more… Instant gold karat reading • Fast and accurate • Non-destructive.
-
Product
Ultrasonic Flow Meters
-
Dalian Taijia Technology Co.,Ltd
RS485 .4-20mA and OCT output● 4-20mA and PT100 platinum resistance input● 2×20 English letters LCD display● 4 key tactile-feedback membrane keypad● IP57● Operate with clamp on, insertion and flow-cell transducer● Pipe diameters from 15mm to 6000mm
-
Product
Precision Thermometer
F252
-
ASL's F252 provides high accuracy, dual channel temperature measurement with Platinum Resistance Thermometers - PRTs - and uses AC bridge technology as developed by ASL for Standards Laboratories throughout the world. Model F252 requires no regular recalibration, the AC circuit techniques eliminating thermal EMFs and drift, while providing excellent long term stability. Front panel data entry allows you to enter probe calibration data into the F252's memory, so that thermometer resistance can be accurately converted to temperature in C, F or K. This can be password protected to prohibit unauthorised or accidental data entry.
-
Product
Temperature Calibration
-
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.
-
Product
Counter Electrodes
-
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.
-
Product
Platinum Electrodes – Multiple Configurations & PEEK Housing Options
PEM1
-
High-purity platinum electrodes available in mesh, wire, coil, ring, rod, disc, and sheet formats. Suitable for CV, LSV, EIS, electrocatalysis, electrolysis, corrosion testing, and fuel cell research. Optional PTFE or PEEK insulation, multiple sizes, and custom configurations support a wide range of electrochemical applications.
-
Product
Cross Flow Cell
-
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
Product
Digital Melting Point Apparatus
DRK8011
-
Shandong Drick Instruments Co., Ltd.
DRK8011 Digital melting point apparatus is fully in line with ‘humanize’ of the design concept, using photoelectric automatic detection, dot matrix image LCD technology, digital keyboard input, each measuring one sample, measure three times the average of the melting point of the automatic strike, and has a melting, melting end automatically, melting curve automatic recording function. Temperature system uses high inearity make platinum resistance sensing element, the use of PID regulationtechnology to improve theaccuracy and reliability of the melting point, and with integrated electronic circuits to achieve rapid "starting temperature" setting and eight stalls to choose from linear "heating rate" Automatic Control. Instrument to establish communication with the PC via USB, save or print the graph, the instrument can be directly connected with the RS232 mini-printers, print graphs. The instrument uses Pharmacopoeia as a sample capillary tube.
-
Product
Working Electrodes for Flow Cell
-
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
Product
Ruthenium Iridium / Iridium Tantalum / Platinum Titanium Electrode
RRC-1
-
Ruthenium/iridium-based titanium anodes with high corrosion resistance and stable electrochemical performance. Suitable for electrolysis, electroplating, wastewater treatment, and research applications. Custom coatings, geometries, and Ti plate/mesh formats are available.
-
Product
Grid Electrode
-
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
Product
Platinum Interdigitated Electrode On Quartz
RIE1
-
Quartz-based platinum IDE for gas sensing, biosensing, MEMS, photoelectric, and electrochemical applications.
-
Product
Vigilant Aircraft Hygrometer
137
-
The Edgetech Instruments Model 137 Vigilant Aircraft Hygrometer is a rugged, shock mounted military qualified instrument used for the primary measurement of dew point in flight or in installations with existing flow, such as wind tunnels.It features a miniature remote dew point sensor employing a platinum resistance thermometer, and has 15 feet of interconnecting cable to the control unit. Precision calibration units for the linear analog outputs are included.
-
Product
Working Electrodes
-
PotentioLab provides working electrodes for electrochemical analysis, electrocatalysis, sensing, corrosion research and material screening. The range includes glassy carbon, platinum, gold, graphite and custom working electrodes with practical exposed areas, holders and connector options.
-
Product
Environmental Test Chamber
-
The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip.The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1 and humidity is 0.1%R.HThe temperature sensor is platinum PT100 Ohms/MV resistor
-
Product
FTP Patch Cable, 5″ C6, 4/Clam
#610025C
-
Platinum Tools’ premium 5″ Cat6 FTP Patch Cables are made with testing networks in mind. Plug in and out all day long and know you will have consistent and precise connectivity every time. Designed for repititive, long cycle life! 849160007951