Line Fault Indicators
See Also: Overhead Line
-
Product
Indicators - Dial
-
Used for precise comparisons or measurements of workpiece surfaces, machine, equipment, part tolerances, alignment.
-
Product
Humidity Indicators
-
A humidity detector, also referred to as a humidity meter or humidity gauge, is a device with a humidity sensor that measures the relative humidity in the air. PCE Instruments offers a number of humidity detector products including handheld humidity detector, data recording or data logging humidity detector, and combination or multifunction humidity detector devices that also measure parameters such as room or ambient temperature and atmospheric or barometric pressure. A humidity detector can measure relative humidity (RH) as a percentage (%) from 0 to 100 % RH, depending on the humidity measurement range of the specific model.Humidity is a key factor in everything from library and museum archival to agriculture, construction, manufacturing, transportation, warehousing, and heating, ventilation, air conditioning and refrigeration (HVACR). A relative humidity meter also is helpful in evaluating workers' heat stress risk on production floors and job sites. In addition, humidity plays an important role in the residential sector. If the humidity is too high in a private household, mold can grow. Mold creates a health hazard for anyone breathing the air in the home.
-
Product
Voltage/Current Indicator
CS3S-VA
-
● Measuring: DCA, DVC, ACA, ACV● Accuracy: ±0.1%(DB), ±0.2%(AC)● Display range: -1999~9999● Dimension: 1/32 DIN (48x24mm)● High Stability and reliability
-
Product
Temperature Indicator
TICT
-
The LogTag® TICT is a low cost disposable electronic temperature indicator for use in monitoring temperature & time statistics in transport applications of up to 45 days duration. The LogTag® TICT can monitor and record statistics against four factory pre-set temperature limits for up to 45 days, displaying ‘OK’ if environmental conditions remain within limits. If temperatures exceed two high temperature alarm limits or go below two low temperature alarm limits, the LCD shows a ‘REJECT’ alert, indicating the goods require further checking.
-
Product
Voltage Indicator
-
Small installation devices for measuring both alternating and direct voltages.
-
Product
Line Splitters
-
Precision Mastech Enterprises Co.
Allow for safe, accurate current measurements using a clamp-on ammeter without damaging or stripping the appliance's power cord.
-
Product
Bar Indicators
-
Orbit Controls bar displays are flush-mounted display devices with one or two three-color bars. They can also be ordered with a digital display. The devices are designed for connection to various process signals and can be equipped with control outputs.
-
Product
Cable Indicators
CableTroll
-
They are installed on Ring Main Units in distribution substations. They are used to detect short circuit and earth faults, and can be installed on most types of cable terminations. Some units will give separate indications for short circuit and earth faults, locally by flashing diodes and remotely through separate relay contacts or additional ComTroll communications modules.
-
Product
Fault Locators
-
For the first time, you can detect the type of fault and locate the position of an electrical fault that causes intermittent or persistent circuit breaker trips, thus giving you the critical information needed to reduce call backs for circuit breaker trips.
-
Product
Fault Locator
WEEZAP
-
WEEZAP is an LV vacuum circuit breaker combined with advanced measurement and protection capability.
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
Fault Insertion Unit
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
Switch Indication Maintainer
The SIM
-
The SIM - Switch Indication Maintainer is a handheld device used to simulate normal switch correspondence while the switch is handthrown or handcranked to perform periodic maintenance or testing.
-
Product
Test Voltage Indicators
PRV240FS
-
Verify your test tool works without unnecessary exposure to shock and arc flash. Make the process easy by using the PRV240FS Proving unit. Verifying that your T6 electrical tester is working properly reduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification before tests are performed.
-
Product
Safe Load Indicators
-
Micro Edge Electronics Private Limited
By keeping track with the market development, we are involved in offering world class Digital Load Indicators / Controllers. The offered range is widely used for mV signals from up to four 350 / eight 700 load cells. Our offered range is manufactured using high quality raw material and latest techniques in accordance with the international standards. Appreciated among clients for their high tensile strength, robust construction and optimum efficiency, these are widely demanded all across the globe.
-
Product
Line Impedance
KIT
-
The Line impedance kit is composed of two modules, STLG and STSG. The kit is meant to be used with STS 5000, STS 4000 and eKAM in order to perform Line Impedance test.
-
Product
Dial Indicators
-
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
Product
OverHead Lines Contact Voltage & Low Voltage Indicator
LVD-415
-
Standard Electric Works Co., Ltd
● No batteries required.● Every circuit is doubled.● Buzzer indicates voltage detected.● Led indicates voltage detected.● Neon scale indicates voltage.● Dual HBC fuses.● High grade fiber glass probes.● Super polished fiber glass.● High strength connecting cord.● Heavy duty rated.● Replaceable tips.● Choice of tips available.● Lightweight.● Small storage space.● Strong strength reliefs.● Double poles non-polarized.● Suitable for 45 to 70 Hz networks.● Contact detector type.● Passive circuitry.● Fiber glass 1.6mm - CU 35um PCB.● Super bright neon lights and LEDs.● Ergonomically-designed.● EN 61010-031 CAT IV 500V.
-
Product
Magnetic Level Indicator
VEGAMAG
-
A safe, durable, and non-invasive instrument used to measure liquid levels in tanks or pressurized vessels.
-
Product
Digital Temperature Indicators
-
Premier's Temperature Indicators are commonly used for applications like monitoring of melting furnaces, determining completion of chemical analysis, monitoring of conveyors, checking completion of heating cycle, monitoring of moulds and dies, preheating temperature confirmation, determining temperature rise, preforming heat treatment, checking temperature in manufacturing process, transporting chemicals, laying pipelines with wall and sub sea temperature measurements.
-
Product
Cable Fault Locator
FaultCaster
-
Low Cost Full specification Professional Digital TDR Measures Distances to Open or Short Circuit Faults Extended Measuring Range to 2000m (6000ft) on all cable types Fast-Edge Step TDR technology for improved range & Resolution
-
Product
Microprocessor Based Indicator
-
Strong Anodized NEMA4X-IP56 ALUMINUM 1/8 DIN CASE Compact Design Provides Excitation to Transducers or Sensors Accept DC mV/V, V, mA Signal Proportional Analog Output V or mA Easy to Program using 4 ButtonsFront Panel Shunt Calibration User Programmable High & Low Set Point Standard No-Output or Relay Output Optional 8-Step Output, RS232, or BCD Output Available
-
Product
Fault Location
REFLEKT
-
REFLEKT makes fault location more efficient, effective and practicable than ever before, even on complex networks.
-
Product
Remote Indicators
-
ABB field indicators provide a convenient way to access the field instruments data when they are located in remote or difficult to access areas. Powered directly from the 4-20 mA current loop, they require minimal effort to setup.
-
Product
Cable Fault Location
-
BAUR cable fault location devices and systems cover the entire cable fault location process: During pre-location, the position of the fault is roughly located. The subsequent pinpointing enables precise determination of the cable fault. You can use various measurement methods depending on the kind of fault and cable type.
-
Product
Lining Thickness Measurement
-
ElektroPhysik Dr. Steingroever GmbH & Co. KG
Measuring the lining thickness of rotary kilns is an important process in the industry, especially in cement production. The lining of a rotary kiln consists of refractory material that has to withstand high temperatures and chemical stresses to ensure a smooth production process. The thickness of the lining is of great importance because it has a direct influence on the efficiency, safety and service life of the rotary kiln. Measuring the lining thickness is therefore an important and fundamental aspect when it comes to the safety of rotary kilns.
-
Product
Pole Mounted Detector of PtG and PtP faults in 6-69V Line
LineTroll 111K
-
The unit mounts 3-5m below the conductors and monitors all three phases. The indicator is powered by replaceable long-life lithium batteries which have a lifeexpectancy of 10-15 years. It provides a 360 degree visibility for indication both for transient faults and permanent faults.
-
Product
Line Scan Camera
8M Series
-
The USB Line Camera 8M is an easy-to-use cost-effective board-level line scan camera. It consists of two circuit boards, the main circuit board and the sensor circuit board.
-
Product
Fault Injection Module
WF 3154 C-Series
-
The WF 3154 from WireFlow is a 4-channel Fault Injection Module for Compact RIO. Each channel provide three solid state relays that can be used to create electrical fault conditions like: Open circuit, Short circuit to battery, Short circuit to ground.
-
Product
Phase Indicators
-
Kyoritsu Electrical Instruments Works, Ltd.
New technology permits safe testing, without the need of direct contact between probes and live wires. The insulated crocodile clips can clip insulated cables from 2.4 to 30mm. Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones. The instrument can be fixed to a metal panel via the magnet on the back side. Wide measuring range for 3 phase installations from 70V to 1000V AC. Super brightness function permits clear LED''''s indication also in sunshine. Complies with IEC 61010-1 CAT IV 600V and CAT III 1000V.