RF / Microwave Switches
-
product
96-Pin Male SCSI to 96-Pin Female SCSI Switch Cable, 1.5m
150275-1R5
96-Pin Male SCSI to 96-Pin Female SCSI Switch Cable, 1.5m - The SH96F-96M SwitchBlock SCSI Cable provides connectivity for SwitchBlock modules. You can connect these to the TBX-2809 Terminal Block, which exposes each channel of the switch module to screw terminals.
-
product
50Ω uWave SMA 2.92 Cable Assembly, 40GHz, 1m
40-977-544-1m
50 Ohm uWave SMA 2.92 Plug to uWave SMA 2.92 Plug Cable Assy, 1m Long.
-
product
High-Density PXI Multiplexer Switch Modules
This range of High-Density Multiplexer Switch Modules provides a compact array of MUX solutions with differing combinations of channel counts and poles. Most of our high-density solutions include isolation relays that allow the MUX to be disconnected from the single input/output port, enabling the convenient interconnection of other channels.
-
product
LXI Microwave Multiplexer, SP6T, 11-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-511
Our 60-800-511 is a 11 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
LXI Microwave Multiplexer, 50Ω 6-Channel 15-Bank 40GHz SMA-2.9
60-801-415
The 60-801-415 is a 6-channel, 15-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
40GHz Single Channel Microwave Signal Generator Module
LSX4091D
The LSX4091D is a 40GHz Single Channel Microwave Analog Signal Generator that offers industry leading performance, in a modern modular format that can be used on the desk, embeded in a system or as a portable unit. It features USB control, exceptionally fast switching speed, superior signal integrity and purity and all the necessary modulated signals for analog communication systems. The design offers excellent performance and meet today’s most demanding applications, whether in the lab or out in the field.
-
product
PXI Hex SPDT RF Switch SMB 75 Ohm
40-830-006
The 40-830-006 is a 75Ω RF Switch 6 separate SPDT relays in a single PXI slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks have been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
LXI Microwave Multiplexer, SP6T, 14-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-514
Our 60-800-514 is a 14 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
LXI Microwave Multiplexer, SP6T, 10-Bank, 50GHz, 50Ω, SMA-2.4, Terminated
60-800-710
High performance RF multiplexer suitable for switching microwave signals up to 50GHz with automatic termination of unused signals
-
product
High 2.90 (82.20) - 12.60 (357.00) Switch Probe
TSP100-C100-3
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
PXI 10A Fault Insertion Switch 6-chan 2-bus
40-192-012
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
product
Push-Back & Push-Back Switch Probes
Connector assembly check - extreme spring force - used in test modules.
-
product
LXI High Voltage Switching - 50xSPST Plugin Module
65-233-900-HI
The 65-233-900-HI plug-in module is part of a scalable high voltage switch platform that provides a high voltage switching solution with capability up to 9 kV.
-
product
PXI/PXIe RF Switch, Dual SPDT, Terminated, 8GHz, 50Ω, SMA
40-880B-001
The 40-880B-001 (PXI) and 42-880B-001 (PXIe) are dual SPDT 50Ω RF switches with 8GHz bandwidth. The 40/42-880B range has automatic termination of unused signals and are available as a dual switch in 1 slot, a quad switch in a two slots or hex and octal switches in three slots.
-
product
75 Ohm SMZ/Type 43 Cable Assembly
40-977-711-0.5m
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
product
LXI Microwave Multiplexer, SP6T, 13-Bank, 18GHz, 50Ω, SMA
60-800-113
Our 60-800-113 is a 13 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
PXI Octal SPDT RF Switch, 8GHz 50Ω SMA, Terminated
40-880A-004
The 40-880A-004 is an octal SPDT 50Ω RF switch with 8GHz bandwidth. The 40-880A range of SPDT switches have automatic termination of unused signals and are available as a dual switch in a 1-slot PXI module, a quad switch in a 2-slot PXI module or hex and octal switches in 3-slot PXI modules.
-
product
PXI Microwave Transfer Switch, Dual, 26.5GHz, 50Ω, SMA
40-782B-532
The 40-782B-532 (PXI) and 42-782B-532 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 26.5GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
product
PXIe Microwave Multiplexer, Single SP4T, 26.5 GHz, 50 Ω, SMA, Failsafe
42-784B-131
The 40-784B-131 (PXI) and 42-784B-131 (PXIe) are single failsafe SP4T 26.5 GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
High Performance LXI Microwave Multiplexers
Pickering's LXI Microwave Multiplexers offer the highest density microwave multiplexer configurations possible, packaging 16 multiplexers into a 2U high rack. All versions of this multiplexer have an extremely high level of performance, offering low VSWR, high isolation, low loss and high power handling. Occupying only 2U of valuable rack space - our microwave multiplexers provide a space saving solution for systems requiring high performance multiplexers in the construction of microwave switching systems.
-
product
PXI Signal Insertion Switch Module
PXI Signal Insertion Switch Modules, also known as fault insertion units (FIUs), provide a set of feedthrough channels, which make the switch transparent to the system when closed. You can open or short these channels to one of two fault buses, allowing you to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI Signal Insertion Switch Module can validate the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs). You can also use the FIU models for hardware-in-the-loop (HIL) applications and electronic reliability tests.
-
product
PXIe Microwave Relay, Single SPDT, 26.5 GHz, 50 Ω, SMA, Internal Termination, Failsafe
42-781A-221
The 40-781A-221 (PXI) and 42-781A-221 (PXIe) are single failsafe SPDT 26.5 GHz microwave relay modules with internal terminations. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
product
PXI Matrix Switch Module
PXI Matrix Switch Modules are organized into rows and columns and provide maximum flexibility for switching systems by allowing you to connect any channel to any other channel. PXI Matrix Switch Modules use a variety of relay types, including electromechanical armature relays, reed relays, field-effect transistor (FET) relays, and solid-state relays, each with their own benefits, allowing you to choose a matrix that fits your requirements. To program the switches, you can use the IVI-compliant NI-SWITCH driver software, complete with help documentation, example programs, and a soft front panel application for interactive control of switches. For intelligent management of complex switch systems, NI Switch Executive provides additional software tools to help you design, build, and deploy your switching system.
-
product
PXI Microwave Relay, Dual SPDT, 26.5GHz, 50Ω, SMA
40-780B-532
The 40-780B-532 (PXI) and 42-780B-532 (PXIe) are dual SPDT 26.5GHz unterminated microwave relay modules. The 40/42-780B range is available with one, two, three or four SPDT switches capable of switching frequencies up to 67GHz in 50Ω or 2.5GHz in 75Ω. Connections are made via front panel mounted high quality RF coaxial connectors, SMA or N-Type for 50Ω and 1.6/5.6 in 75Ω versions. Remote versions are also available which can support up to three SPDT relays in a single slot.
-
product
LXI Microwave Multiplexer, SP6T, 13-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-513
Our 60-800-513 is a 13 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
50Ω UWave SMA 2.92 Cable Assembly, 40GHz, 0.25m
40-977-544-0.25m
50 Ohm uWave SMA 2.92 Plug to uWave SMA 2.92 Plug Cable Assy, 0.25m Long.
-
product
PXI/PXIe RF Switch, Triple SPDT, 3GHz, 50Ω, SMB
42-870A-003
The 40-870A-003 (PXI) and 42-870A-003 (PXIe) are 50Ω RF switches with 3 separate SPDT relays in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
product
PXI Microwave Transfer Switch, Single, 26.5 GHz, 50 Ω, SMA, Failsafe, Remote Mount
40-782B-531-E
The 40-782B-531-E (PXI) and 42-782B-531-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 26.5 GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
product
PXI Solid-State Switch Module, 3xSPST, 25 A, 100 V, Hardware Interlock
40-184A-002-HI
The 40-184A-002-HI has 3-off high current SPST switches with hardware interlock in one PXI slot and is part of our range of high power solid state switching solutions.
-
product
PXI Dual Transfer Switch 18GHz 50Ω SMA
40-782-522
The 40-780 Microwave switching module consists of one, two, three or four changeover switches capable of switching frequencies to 18GHz (optionally to 67GHz) in 50Ω or 2.5GHz in 75Ω. The 40-782 module consists of one or two microwave transfer switches. It has a characteristic impedance of 50Ω and is available in versions with maximum operating frequencies of 18GHz, 26.5GHz or 40GHz.