Rubidium Standards
In telecommunication, a rubidium standard is a frequency standard in which a specified hyperfine transition of electrons in rubidium-87 atoms is used to control the output frequency. (www.encyclopedia.thefreedictionary.com)
See Also: Rubidium Reference, Rubidium Oscillators, Frequency Standards, Rubidium Frequency Standards
-
Product
Standard Voltage 50 Pin D-Type Cables - Connector to Connector for Pickering
-
The connector to connector cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
Product
Standard Voltage 37 Pin D-Type Cables - Connector to Connector
-
The connector to connector cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1B-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PCI Standard Programmable Resistor Cards
-
Pickering's PCI Standard Programmable Resistor Cards include fully programmable resistor and potentiometer cards for applications such as sensor emulation that require fine adjustment with a resolution down to 0.25 Ohm. All of our Programmable Resistor Cards can easily be formed to make Programmable Potentiometers by connecting two channels in series, using the unconnected terminals as the A and B connections and the link between the two channels as the wiper connection.
-
Product
600MM 24In Digital Level Bevel Gauge w/ LCD Backlight Screen, Level Bubbles, IP54 Standards
DL406
-
Advance Plus Trading Co., Ltd.
Model Number: DL406 Key Specifications/Special Features: 600MM 24INCH Digital Level with level bubbles,LCD bright backlight display, IP54 standards 1. 600mm 24 inch level with 2 bubbles, 600*28*64mm(L*W*H), net weight: 520g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13.Handshank design, easy to take and use;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35 Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
STANAG3910 Electrica lTest And Simulation Modulefor Standard Ethernet
ANET3910-EN
-
STANAG3910 Electrical Test and Simulation module for Standard Ethernet. The ANET embedded Linux operating system gives the unique capability to run the optional PBA.pro Engine right in the box.Another option is the ANET-ADK onboard software development kit where users create run-time applications to execute right in the box. For wireless applications, an ANET compatible USB Wifi dongle is optionally available. The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET Docking Station to host up to 4 ANET modules.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2X
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-J100-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39T15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I35-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25Z-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 3.00 (85.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
G-S-R
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
Sample Support Holder – Standard 1 Cm² / Custom Reaction Area
SSH-1
-
The Sample Support Holder is designed for mounting flat samples in electrochemical cells and defining a controlled exposed area. Manufactured from PTFE, it accommodates samples 0.1–2 mm thick and 12–14.5 mm in diameter, with a standard exposure area of 1 cm².
-
Product
Frequency Standard Products
-
The ES-110 generates a stable source of 10 MHz using GPS (Global Positioning System) satellites as a reference. If frequency distribution is needed, we offer the ES-210, a Quad 1x6 1/5/10 MHz Distribution Amplifier. The ES-210 provides four independent 1x6 Frequency DAs in a single rack-mount enclosure. The ES-410 is a four output version of the ES-110. The ES-410 was introduced and won Radio Magazine's Best of Show Award at the 2016 NAB Show.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T156
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Beagle USB 5000 v2 SuperSpeed Protocol Analyzer - Standard Edition
TP322510
-
The Beagle™ USB 5000 v2 SuperSpeed Protocol Analyzer - Standard Edition is our lowest priced USB 3.0 model, and one of the most advanced USB 3.0 protocol analyzers available. Individually selectable options allow you to configure the analyzer to your specific needs today, while the fully field upgradeable design ensures this tool can evolve with your growing needs. Free Data Center Software and cross-platform support for Windows, Linux, and Mac OS X make the Beagle USB 5000 v2 SuperSpeed Protocol Analyzer - Standard Edition a user-friendly and versatile tool for any engineer working with USB 3.0 or USB 2.0.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T65
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T1-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25L-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Single Phase Reference Standard Meter
-
Signals & Systems India Private Limited
The Single Phase Portable Reference Standard (SPRS-1102) from SANDS is a portable meter test equipment that helps to calibrate the error present in the single-phase energy meter i.e. the meter under test (MUT). The SPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, phase angle etc of the meter under test. It has an LCD display and an alphanumeric keypad to suit the user. It can be interfaced with the PC for analysis. It has the capability of storing 1000 test results.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16
85038A
Mechanical Calibration Kit
The Keysight 85038A calibration kit contains open circuits, short circuits and terminations with both male and female 7-16 connectors and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1C1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Standard 1.00 (28.30) - 5.40 (153.00) Battery Probe
BIP-10
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 157Full Travel (mm): 4.00Recommended Travel (mil): 126Recommended Travel (mm): 3.20Overall Length (mil): 591Overall Length (mm): 15.00
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
European Standard for Remote Reading of Measuring Devices
M-Bus
-
M-Bus (Meter-Bus) is a European standard for remote reading of measuring devices. M-Bus is predominantly used in buildings, for example in electricity meters, gas meters, water meters or other types of consumption meters. It is also used for various sensors and actuators.
-
Product
Automatic Voltage Regulating Relay- Standard Model
-
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.





























