P2532 General Purpose Probes
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 156Test Center (mm): 3.96Full Travel (mil): 139Full Travel (mm): 3.53Recommended Travel (mil): 93Recommended Travel (mm): 2.36Overall Length (mil): 812Overall Length (mm): 20.62Rec. Mounting Hole Size (mil): 94.5Rec. Mounting Hole Size (mm): 2.40Recommended Drill Size: #41 or 2.40 mm
-
Product
P2757 General Purpose Probes
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
3GHz Single Channel Signal Generator
LS3081B
Signal Generator
The LS3081B is a 3GHz Single Channel RF Analog Signal Generator, offers industry leading performance, in an easy to use benchtop box. It features exceptionally fast switching speed, superior signal integrity and purity and all the necessary modulated signals for analog communication systems. The design offers excellent performance and abilities combined with an affordable price tag, needed from the R&D benches to the production lines.
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-2R1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1P2S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Waveform Generator, 120 MHz, 1-Channel
33621A
Waveform Generator
Keysight 33600A Series waveform generators with exclusive Trueform signal generation technology offer more capability, fidelity and flexibility than previous generation DDS generators. Easily generate the full range of signals you need to your devices with confidence the signal generator is outputting the signals you expect.
-
Product
PXIe Microwave Relay, Dual SPDT, 26.5 GHz, 50 Ω, SMA, Failsafe
42-780B-532
Microwave Relay Module
The 40-780B-532 (PXI) and 42-780B-532 (PXIe) are dual failsafe SPDT 26.5 GHz unterminated microwave relay modules. The 40/42-780B range is available with one, two, three or four SPDT switches capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via front panel mounted high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions are also available which can support up to three SPDT relays in a single slot.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-4
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
PXI/PXIe Microwave Relay, Quad SPDT, 26.5GHz, 50Ω, SMA
40-780B-534
Microwave Relay Module
The 40-780B-534 (PXI) and 42-780B-534 (PXIe) are quad SPDT 26.5GHz unterminated microwave relay modules. The 40/42-780B range is available with one, two, three or four SPDT switches capable of switching frequencies up to 67GHz in 50Ω or 2.5GHz in 75Ω. Connections are made via front panel mounted high quality RF coaxial connectors, SMA or N-Type for 50Ω and 1.6/5.6 in 75Ω versions .Remote versions are also available which can support up to three SPDT relays in a single slot.
-
Product
LXI Microwave Multiplexer, SP6T, 5-Bank, 26.5GHz, 50Ω, SMA
60-800-305
Microwave Multiplexer
Our 60-800-305 is a 5 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Generators
Linear Frequency-Modulated Signal Generator
-
The Software Signal generator allows to produce frequency modulated signals with linear sweep at the DAC output.
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5B
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
PXIe3.0-based 2.5GS/s Arbitrary Waveform Generator
P2500M
Waveform Generator
The P2500M series is a PXIe3.0-based 2.5GS/s arbitrary waveform generator module that provides technologically advanced options and configurations, such as dual-channel 5.4GS/s ADC signal acquisition channels with 9GHz bandwidth, which can convert the instrument to arbitrary waveform transceivers device. The P2500M offers industry-leading performance including innovative task-oriented programming, real-time data streaming, fast feedback loops for environment-based waveform generation, and user-definable FPGAs for application-specific solutions.
-
Product
PCIe 16 Bit Arbitrary Waveform Generator - up to 40 MS/s on 1 Channel
M2P.6530-X4
Arbitrary Waveform Generator
The M2p.65xx series offers different versions of arbitrary waveform generators for PCI Express with a maximum output rate of 125 MS/s. These boards allow to generate freely definable waveforms on several channels synchronously. With one of the synchronization options the setup of synchronous multi channel systems is possible as well as the combination of arbitrary waveform generator with digitizers of the M2p product family. The 512 MSample on-board memory can be used as arbitrary waveform storage or as a FIFO buffer continuously stream data via the PCIe interface. Importantly, the high-resolution 16-bit DACs deliver four times the resolution than AWGs using older 14-bit technology.
-
Product
Ultra High 12.90 (366.00) - 48.00 (1361.00) General Purpose Probe
EPA-5H-2
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Ultrastable Microwaves
-
Ultra-stable microwave sources are paramount for a broad range of applications, including precision metrology, deep space navigation, telecom and next generation wireless communication, as well as coherent radar. With the PMWG-1500 Menlo Systems offers a unique commercial solution for providing ultrastable microwaves in an all-in-one solution.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-9
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
6GHz Single Channel Signal Generator 19" 1U Rack Module
LS6081R
Signal Generator
The LS6081R, 6GHz Single Channel RF Analog Signal Generator, offers industry leading performance, in a 1U, 19” rack-mounted box. The LS6081R features exceptionally fast switching speed, superior signal integrity and purity and all the necessary modulated signals for analog communication systems. The LS6081R was designed to offer excellent performance and abilities combined with an affordable price tag, needed from the R&D benches to the production lines.
-
Product
Microwave and mmWave
Tx/Rx
-
Analog Devices offers complete transmitter (Tx) and receiver (Rx) solutions for microwave (w) and millimeter wave (mm wave) applications. With the need for greater integration and improved performance in multiple industries and technologies, Analog Devices' industry-leading, ready to use transmitter and receiver chipsets for E band, V band, and microwave applications help designers reach new limits in their radio designs. This product family's integrated chipsets can be used for backhaul communications, VSAT, small cell networks, broadband local networks, and other applications.
-
Product
High Definition Arbitrary Waveform Generator
T3AWG Series
Arbitrary Waveform Generator
T3AWG3K Series consists of six high definition high performance Arbitrary Waveform Generators (HD AWG) consisting of 2, 4 and 8 channels, 16 bit vertical resolution, 12 Vpp max output voltage (50Ω into 50Ω), 128 Mpts/ch memory (optional 1 Gpts/ch), a maximum sampling rate of 1.2 GS/s and a max sinewave frequency of 250 MHz and 350 MHz respectively. The baseline HW voltage offset capability provide the unmatched ability to generate ±24 V or 48V output voltage window (50Ω into High Impedance).
-
Product
P2664 General Purpose Probes
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T80
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
A-S General Purpose Probes
General Purpose Probe
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
Product
Microwave Relays
CXM/2x2
-
CXM/2x2-F-SMA Microwave Relays have a Normally Closed (NC = OFF) and Normally Open (NO = ON) Position as shown in the drawing on the left. They can also be used as a terminated 2x1 relay. Usefull for swapping signals between devices, reversing signal flow or interfacing to larger configurations. Specifications Bandpass DC to 18 GHz Insertion Loss 0.3 dB @1 GHz, 0.8 dB @ 18 GHz VSWR 1.2:1 @ 1 GHz, 1.5:1 @ 18 GHz Isolation -80 dB @ 1 GHz, -60 dB @ 18 GHz
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2P
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
PXI-5651, 3.3 GHz RF Signal Generator
779670-01
Signal Generator
3.3 GHz PXI RF Analog Signal Generator—The PXI‑5651 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXI‑5651 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.
-
Product
VXG Vector Signal Generator
M9484C
Vector Signal Generator
The M9484C VXG is the industry’s first dual-channel vector signal generator capable of generating signals up to 54 GHz with 2.5 GHz of modulation bandwidth per channel. The VXG vector signal generator helps you deliver the next frontier of wireless technology such as 5G and satellite communications with a fully integrated, calibrated, and synchronized solution.
-
Product
Microwave Testing
170
-
The PICOPROBE® MODEL 170, a high performance microwave probe which incorporates a WR-6 waveguide with our patented coaxial design techniques, has inherent low loss and low dispersion characteristics.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64