Fiber Optic Multiplexers
Process multiple optical signals into one single optical signal.
-
Product
PXI/PXIe RF Multiplexer, Single 8-Channel, Terminated, 8GHz, 50Ω, SMA
42-883B-001
Multiplexer Module
The 40-883B-001 (PXI) and 42-883B-001 (PXIe) are single 8 to 1 50Ω RF multiplexers with 8GHz bandwidth and automatic termination of unused signal channels. It is available in 8 to 1 and 16 to 1 configurations in two and three slots respectively.
-
Product
PXI/PXIe MEMS Optical Switch, Quad Insert/Bypass
40-860A-442
Multiplexer Module
The 40/42-860A-442 is a PXI/PXIe quad insert/bypass switch with LC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI/PXIe MEMS RF Multiplexer, Single 4-Channel, 4GHz, 50Ω, SMB
40-878-211
RF Multiplexer
The module is based on the latest micro-electromechanical system (MEMS) switching technology and has low insertion loss and VSWR. In addition, MEMS devices have a long operational life of >3 billion operations and benefit from an operating time of <20 μs allowing greater test system throughput. The multiplexers have excellent and repeatable RF characteristics beyond 4 GHz with each path having a nominally equal insertion loss.
-
Product
PXI 3A Power MUX BRIC, 4-Channel, 48-Pole
40-571-004
Multiplexer Module
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXI Power Multiplexer, 16-Channel, 2 Pole
40-650A-002
Multiplexer Module
The 40-650A-002 is a PXI 16 Channel Power Multiplexer, suitable for switching inductive/ capacitive loads up to 5A at 250VAC.
-
Product
PXI/PXIe High Density 2A Multiplexer, 4-Bank, 16-Channel, 2-Pole
42-614D-007
Multiplexer Module
The 40-614D-007 (PXI) and 42-614D-007 (PXIe) 4-bank, 16-channel, 2-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe RF Multiplexer, Single 16-Channel, Terminated, 8GHz, 50Ω, SMA
42-883B-002
Multiplexer Module
The 40-883B-002 (PXI) and 42-883B-002 (PXIe) are single 16 to 1 50Ω RF multiplexers with 8GHz bandwidth and automatic termination of unused signal channels. They are available in 8 to 1 and 16 to 1 configurations in two and three slots respectively.
-
Product
PXI Very High Density Multiplexer, 2A, 79-Channel, 2-Pole, Single Channel Mode
40-611B-002
Multiplexer Module
The 40-611B-002 (PXI) and 42-611B-002 (PXIe) modules are 79-Channel 2-Pole multiplexers. A 158-Channel 1-Pole configuration is also available. They use high quality electro-mechanical signal relays allowing switching up to 2 A and voltage up to 300 VDC/240 VAC.They are suitable for signal routing in high channel count ATE and data acquisition systems. Connections are made via a front panel 160-pin DIN 41612 connector.
-
Product
PXI/PXIe High Voltage Multiplexer, Single 48-Channel, 1-Pole
40-321-109-HI
Multiplexer Module
The 40-321-109-HI (PXI) and 42-321-109-HI (PXIe) are single 48-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PXI 10A Power Multiplexer, 4-Bank, 4-Channel (SP4T)
40-661A-101
Multiplexer Module
The 40-661A-101 is a single pole, 4-bank, 4-channel (SP4T) PXI power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available.
-
Product
PXI MUX 4 Bank, 16 Channel Screened 1 Pole
40-610-021-S-4/16/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI 8-slot BRIC Power Multiplexer, 18-Channel, 16-Pole (8 Sub-cards)
40-571A-206
Multiplexer Module
The 40-571A-206 is a 18-channel, 16-pole 3 Amp Power Multiplexer and is part of our BRIC family. The 40-571A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP12T, 18 GHz, 50 Ω, SMA, Terminated, Failsafe
42-788-221-T
Multiplexer Module
The 40-788-221-T (PXI) and 42-788-221-T (PXIe) are single failsafe SP12T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
Product
LXI Microwave Multiplexer, SP4T, 13-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-803-513
Multiplexer Module
High performance RF multiplexer suitable for switching microwave signals up to 40GHz with automatic termination of unused signals
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 2-Bank 26.5GHz SMA
60-802-302
Multiplexer Module
The 60-802-302 is a 4-channel, 2-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
Multiplexed Measurement Unit
YAV90MMU
Multiplexer Module
YAV90MMU module (Multiplexed Measurement Unit) is a powerful subsystem containing 16-channel multiplexer and a 600V data acquisition channel with capability to control external switching and it is expandable through CAN bus.
-
Product
PXI Microwave Multiplexer, Dual SP4T, 26.5GHz, 50Ω, SMA, Terminated
40-785C-432-T
Microwave Multiplexer
The 40-785C-432-T (PXI) and 42-785C-432-T (PXIe) are dual SP4T 26.5GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI/PXIe MIL-STD-1553 Multiplexer, Single 8-Channel, 2-Pole
42-739-003
Multiplexer Module
The 40-739-003 (PXI) and 42-739-003 (PXIe) are single 8-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
Product
PXI Dual SP6T Multiplexer 18GHz 50, SMA
40-785B-522
Multiplexer Module
The 40-785B-522 is a dual 6-channel 18GHz unterminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PCI 2 Amp Multiplexer, Dual 4-Channel, 4-Pole
50-635A-107
Multiplexer Module
The 50-635A-107 is a dual 4-channel, 4-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 26.5 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-784B-132-E
Multiplexer Module
The 40-784B-132-E (PXI) and 42-784B-132-E (PXIe) are dual failsafe SP4T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe High Density 2A Multiplexer, 8-Bank, 16-Channel, 1-Pole
42-614D-003
Multiplexer Module
The 40-614D-003 (PXI) and 42-614D-003 (PXIe) 8-bank, 16-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI 2 Amp Multiplexer, Quad 16-Channel, 1-Pole
40-635A-008
Multiplexer Module
The 40-635A-008 is a quad 16-channel, 1-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI High Density Multiplexer, 4-Bank, 16-Channel, 1-Pole, Screened
40-610A-014
Multiplexer Module
The 40-610A-014 is a screened 4-bank, 16-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 13-Bank 26.5GHz SMA
60-802-313
Multiplexer Module
The 60-802-313 is a 4-channel, 13-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 67 GHz, 50 Ω, SMA-1.85, Terminated, Remote Mount, Failsafe
42-785C-572-TE
Multiplexer Module
The 40-785C-572-TE (PXI) and 42-785C-572-TE (PXIe) are dual failsafe SP6T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 18GHz, 50Ω, SMA
40-785C-522
Multiplexer Module
The 40-785C-522 (PXI) and 42-785C-522 (PXIe) are dual SP6T 18GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI/PXIe High Density 2A Multiplexer, 4-Bank, 4-Channel, 8-Pole
40-614D-009
Multiplexer Module
The 40-614D-009 (PXI) and 42-614D-009 (PXIe) 4-bank, 4-channel, 8-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 26.5GHz, 50Ω, SMA, Remote Mount
40-785C-431-E
Multiplexer Module
The 40-785C-431-E (PXI) and 42-785C-431-E (PXIe) are single SP4T 26.5GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI 2 Amp MUX, Dual 4-Channel 4-Pole
40-635-107
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.