Partial Discharge
voltage discharge within an insulator causing dielectric breakdown.
See Also: Partial Discharge Detection, Partial Discharge Monitors, PD, PD Test, Partial Discharge Test
-
product
Portable Switchgear Partial Discharge
PD-SG1
The PD-SG1 is a dual transducer Switchgear PD detection instrument. The unit detects TEV signals generated by internal discharge, as well as acoustic discharge generated by surface tracking or corona.
-
product
Partial Discharge Testing Equipment
PD-Analyser
This is an ‘All in One’ solution for testing and analysing partial discharges in the insulation of high-voltage transformers, cables, GIS and electric machines. The DIMRUS ‘PD Analyser’ help diagnose their insulation state and find any type of defects very effectively.It can be used for temporary or constant monitoring of partial discharge in medium and high voltage systems and cables of any rated voltage.The PD Analyser is the most useful device for condition estimation of high-voltage insulation. This multipurpose device is designed for -Partial discharge measuring in high-voltage insulation at a high noise level.Fast detecting of the defects in different high-voltage equipment and identifying how dangerous they are.
-
product
Horn Antenna
Horn antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in electric assets like GIS and GIL or MV and HV power transformers. It is a broadband antenna with a flat response which makes Horn antenna suitable in a number of different applications. It has been optimized to operate in a frequency range suitable for PD activity monitoring and it was designed to provide maximum sensitivity and high gain.
-
product
Partial Discharge Detecting Systems
Hangzhou Xihu Electronic Institute
Cable PD detecting and positioning system, transformer PD detecting and positioning system, switchgear PD detecting and positioning system, GIS PD detecting and positioning systems.
-
product
Partial Discharge Measurement System
DAC-6021
DAC-6021 is a measurement system for testing Partial Discharge of high frequency equipment, power devices, stator coils, etc.Since the system combines Partial Discharge Measuring Instrument (DAC-PD-3) with Testing Corona-free Variable Frequency Voltage Source (DAC-WT-50) and Testing Shielded Chamber, most external noises are removed, and the measurement is safe.
-
product
C Series Digitizer Module
The C Series Digitizer Module takes both high-speed and high-resolution time- and frequency-domain measurements. It features up to four channels that can sample at speeds up to 20 MS/s—ideal for discrete detection of signals 10 MHz and smaller for applications such as fault detection, partial discharge analysis, and acoustic measurements. The module's store-and-forward architecture allows up to 128 Mbits of measurement data to be sent back to the CompactRIO Controller and analyzed. You can use the module as part of a CompactRIO system and use the LabVIEW FPGA Module to develop an advanced trigger based on low-speed streaming for added flexibility. This digitizer includes the NI-DAQmx driver and configuration utility that simplifies configuration and measurements. NI-DAQmx supports NI programming environments and Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
Solution for Industrial Monitoring
PDScope
Techimp PDSCope is a brand new product of the PDCheck family particularly designed to suit all the requisites of the Techimp TiSCADA systems for on-line monitoring of diagnostic quantities in electrical assets.Techimp PDSCope is a powerful PD analyzer based on Techimp TF Map technology (patented) allowing preliminary noise rejection and automatic calculation of statistical parameters relevant to Partial Discharges.
-
product
TE-Metrology
HIGHVOLT Prüftechnik Dresden GmbH
The TE measurement complements the high voltage test and is part of the routine and type testing of numerous electrical devices. It is one of the most important non-destructive methods for detecting faults in electrical installations. The breakdown of an insulating material usually occurs at an internal weak point, which usually already shows a partial discharge activity in advance. For this reason, measuring partial discharges can help prevent costly damage. The TE measurement is thus used for quality testing and diagnosis in the factory as well as during on-site testing of cables, GIS, power transformers and transducers or rotating machinery and their components
-
product
Partial Discharge Test System
TPP
The Partial Discharge Test System type TPP is used for non-destructive insulation and quality testing of electrical components (for example according VDE 0110-1, EN 50178, IEC 60270 and IEC 60060).
-
product
Partial Discharge Monitors
Partial Discharge Monitors provide a complete package that includes sensors, cables, data acquisition unit, processing unit (CPU) and software.
-
product
Universal PD & EMI analyzer
Spark P3
Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.
-
product
Acoustic Imaging
Acoustic imaging offers cutting-edge solutions for precise leak detection, partial discharge identification, and mechanical fault diagnosis. With high-performance microphone arrays and advanced algorithms, our products ensure exceptional industrial safety and perfomance.
-
product
Sensor Technology
Power Monitoring and Diagnostic Technology Ltd.
PMDT is the only manufacturer to utilize all 5 types of online partial discharge sensor technology. Using multiple sensing methods ensures that PD activity is always discovered, located, and characterized. PMDT's handheld PDetector and PDStar units have more capability than the high-end diagnostic equipment of the past. The small handheld, battery powered unit can completely perform the test and analysis without the need of a PC. PDetector, PDStar, and PDiagnostic instruments feature high-resolution phase-resolved analysis of PD signals (PRPD and PRPS) in real time, so you get your test results instantly!
-
product
Field Testing Services
Power Monitoring and Diagnostic Technology Ltd.
PMDT offers three levels of testing services both domestically in the US and globally. With the best quality products, complete PD solutions, rich on-site testing experience, experienced partial discharge experts and field engineers, PMDT also provides PDExpert Services -- professional on-site partial discharge detection and location services to help the customers find the potential risks, evaluate the operating status of the electrical assets, and deliver complete and final problem solutions.
-
product
Partial Discharge Tester
19501-K
Chroma Systems Solutions, Inc.
The Chroma 19501-K Partial Discharge Tester is an instrument equipped with AC hipot test and partial discharge detection functions, providing 0.1kV~10kV of AC output, 0.01μA~ 300μA of leakage current, and 1pC~2000pC partial discharge detect ion range for measurement. Chroma 19501-K Partial Discharge Tester is compliant to the IEC60270-1 standard in particular the partial discharge testing requirements for high voltage.
-
product
Partial Discharge Detector
APD-ANNUNCIATOR
The APD-ANNUNCIATOR is a remote partial discharge detection equipment inside any energized cabinet. The probe is installed in the unit under test, instantly reporting its status. This equipment gives a great benefit because it avoids long term damage to the switching equipment.
-
product
Shielded Rooms
HIGHVOLT Prüftechnik Dresden GmbH
Electromagetic field and line-conducted interference needs to be eliminated in order to measure low-intensity partial discharges with a PD background noise level (≤ 1 pC) in accordance with IEC 60270.
-
product
PD Measuring System
TEM
Partial discharge test system for laboratory or on-site measurement according to VDE 0434, IEC 60270 and EN50178 consisting of:*Partial discharge meter TMG*High-voltage coupling capacitors for decoupling of the PD pulses*Partial discharge calibrator TPK for determining the correction factor in the PD test circuit
-
product
High Frequency Current Transformer Clamps
HFCT-20HD & HFCT-60HD™
The HFCT-20HD™ and HFCT-60HD™ are high frequency current transformer sensors designed for partial discharge detection on electric apparatus’ ground returns. Made from superior quality materials, it is designed for any environment.
-
product
Partial Discharge Test Set
We are an unparalleled name in the industry, engaged in manufacturing and exporting Partial Discharge Test Set that is broadly used for instrument transformers to test the discharge of voltage. This test set is manufactured in compliance with set international quality standards using optimum quality components under the observations of our experienced professionals. Further, it is made available in several specifications to meet the exact requirements of the clients. Our offered Partial Discharge Test Set can be owned from us at nominal prices.
-
product
Electrical Safety Testers
A high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
product
Partial Discharge Tester (Dry Type)
Partial Discharge testing is a way of detecting voids or imperfections in insulators that would lead to overheating and breakdown under normal operating conditions. Due to the nature of the signal being measured, this test is very susceptible to electronic and RF noise and a proper corona-free properly isolated test chamber is required.
-
product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
product
Portable Partial Discharge/ Detection
AE-150
The AE-150 is designed to detect and localize Partial Discharge activity inside oil-insulated power transformers. This instrument is a powerful diagnostic tool that combines electric and acoustic sensing technologies to perform partial discharge pinpointing.
-
product
Cable Diagnostic Tools
For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.
-
product
Partial Discharge Testing Equipment
3i
The portable multipurpose 3i device (Intellectual Insulation Indicator) is for eff ective high-voltage equipment insulation monitoring on-line. The 3i device measures and analyses partial discharges (PD). For eff ective PD measurement and noise rejection, there are two types of sensors used in the device: the acoustic sensor and the TEV sensor. Both the sensors are built into the device case, and so do not need any connection cables. The device is supplied in a strong metal case; at the faceplate there are the colored screen and two buttons: power button and function button.
-
product
Ultrasonic Partial Discharge Detector
HTJF-9003
Wuhan Huatian Electric Power Automation Co., Ltd.
Used for on-line detection and localization of partial discharge in high voltage equipment.
-
product
Dielectric Loss Tangent Testing Instruments
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
product
Transformer Testing And Monitoring
Can detect the symptoms of transformer failure by monitoring the cooling system, load tap changer, dissolved gas, bushing power factor and capacitance, partial discharge, oil levels, pressure, temperatures and more.
-
product
Insulation Resistance Meter
AMIC-15k1
The partial discharge indicator PDI. Diagnosis of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD. Allows to test the electrical durability of the tested object - indication of breaking voltage. The high resistance to electromagnetic interference ensures uninterrupted operation in power plants and near high-voltage transmission lines up to 1200 kV AC and 500 kV DC.