Frequency Counters
measure frequency by comparing the signal to the counter's time base oscillator.
See Also: Universal Counters, Time Interval Counters
-
Product
10Hz-150KHz Frequency Counter
HCF-F1000L
-
FEATURE:*Period,totalize measurement self test*High sensitioity:85dBV (25mVrms)*Stability:±3x10-9/s*8 digit LED display*Gate Time:0.01s,0.1s,1s*Power supply:AC 220V(110V optional)
-
Product
Time Interval Counter Card
GC2200 Series
Interval Counter
The GC22x0 family of PCI universal time interval counters offer many of the measurement and timing functions of high-end stand-alone frequency counters, including accumulate, auto ratio, frequency, fast frequency (GC2220 and GC2230 only), period, ratio, single period, test clock, time interval, time interval delay, totalize, totalize gated, totalize gated once, and pulse width.
-
Product
Signal Generator
MAG-2015AD
-
Feature:*Signal frequency: 0.1Hz~15MHz, continued*Wave form: square,sine*Output attenuator: 0dB,20dB,40dB,60dB*Output level: 20Vp-p in open ciruit,not less than 10Vp-p with 50Ω load*Rising edge of Square not more than 35ns at 2MHz*Sine distortion less than 1%,amplitude-frequency characteristic ±0.5dB with in 2MHz, ±3dB above 10MHz*Frequency Counter: 20Hz~30MHz*Power supply: AC 220v (110v optional)
-
Product
Digital Frequency and Multifunction Counter
IBL-FC1300
-
International Biological Laboratories
This is an Intelligent Dual Channel Frequency Counter and has 8 digits LED Display. It measures frequency up to 1.3 GHz.
-
Product
Frequency Counter (225MHz - 18GHz)
S43180
-
S43180 series high-precision frequency counter is a high-precision frequency measurement instrument. It has a frequency measurement resolution of 10 bits per second. The whole machine scheme adopts countdown technology and digital interpolation technology to realize the high-precision measurement of the instrument. It has measurement functions such as frequency, period, frequency ratio and powerful mathematical statistics operations (maximum value, minimum value, average value, PPM, standard deviation, Allan variance).S43180 series has reliable performance, complete functions, high measurement accuracy, wide frequency measurement range, high sensitivity, large dynamic range, high cost performance and easy to use. It is especially suitable for frequency measurement in scientific research and measurement fields such as aerospace, crystal oscillators, and components.
-
Product
Frequency Counter Products
53200 Series
-
The Keysight 53200 Series of 350 MHz universal and RF frequency counter/timers serve all of your frequency and time interval measurement needs. 3 available models offer resolution capabilities up to 12 digits/sec single-shot frequency resolution on a one second gate. Single-shot time interval measurements can be resolved down to 20 psec. All models in 53200 series offer new built-in analysis and graphing capabilities to maximize the insight and information you receive. Use the connectivity of your choice: LXI-C/Ethernet, USB, GPIB. Additionally, an optional battery is available to increase portability and maintain time base accuracy.
-
Product
Function Generators
-
Scientific Mes-Technik Private Ltd
Scientific offer wide range of function generators from 3 MHz to 10 MHz in general purpose and multifunction. Selection of waveform shapes apart from standard sine, triangle , square to ramp, pulse are available. SM5071 , SM5074 , SM5061 & SM5075 have built-in auto ranging frequency counter. The outputs are protected against short circuits and overload.
-
Product
Digital Multimeter
6420 DM
-
Standard Electric Works Co., Ltd
● 4000 counts LCD with a maximum display of 3999.● Angled display design helps the user to identify the reading of value easier.● Auto ranging designed.● Bar graph LCD display.● Range change function.● Relative/Maximum/Minimum modes.● Peak hold mode.● VAHz mode measures frequency in voltage or current mode.● 40M Hz frequency counter.● Auto Power off.● Continuity check.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use.
-
Product
Voltmeter
-
The Voltmeter (like the Sound Level Meter and Frequency Counter) can be positioned anywhere on the screen. The size of the display font changes when you resize the meter by dragging its borders. You can fill the screen for a really big readout that can be seen from across the room.
-
Product
PMR Power Meter
-
The 3030 RF Power Meter is a modern version of the traditional Antenna Watt and VSWR instrument. The instrument cover communication bands from 30MHz to 500MHz. The 3030 RF Power Meter will measure forward and reflected power in the range from milliWatts up to 100Watts. Built in frequency counter. The counter will show the transmit frequency and will call the calibration table for the actual frequency. Outside the range of the counter the instrument can be set into manual mode giving a wider dynamic range. The 3030 RF Power Meter will calculate VSWR or Return Loss, and features Peak and Hold mode. Accessory kit with soft or hard carrying bag, car charger and coax adapters for standard types are available
-
Product
Programmable Multifunction Generator
IST 5800/5850
-
IST Information Scan Technology, Inc.
The IST-5800 series programmable multifunction generator is an exceptionally versatile and economical instrument for applications in R&D, Manufacturing Test, Service Repair and Training. Featuring an adjustable triple output power supply and waveform generator, it has the ability to provide power and signal sources for a circuit while the universal logic probe, auto-ranging frequency counter, and digital voltmeter allows you to simultaneously analyze and measure circuit activity.
-
Product
Resonance Dip Meter
NRM-2
-
National RF’s Resonance Dip Meter is a test instrument used to determine the resonant frequency of a tuned circuit or resonant network, such as an antenna system. In addition, the unit may function as an RF detector, or a secondary frequency source. The instrument is analogous to the older vacuum tube “grid dip meter,” once popular in every electronic laboratory or radio station. Unique to this updated version is a buffered output that may drive a digital frequency counter for exact measurement of resonant frequency, or connected to an oscilloscope to be used as an RF detector and waveform/modulation monitor.
-
Product
350 MHz Universal Frequency Counter/Timer, 12 digits/s, 20 ps
53230A
Frequency Counter
The Keysight 53230A universal frequency counter/timer serves all your frequency and time interval measurement needs. In addition to the typical frequency and time interval measurements, continuous/gap-free measurements are available for basic modulation domain analysis. Optional burst measurement software is available. An optional microwave channel can be added to measure 6 or 15 GHz.
-
Product
HF Frequency Counter LXI, GPIB/IEEE48
53210A
-
For fast and accurate frequency and time-interval measurements, you need reliable devices in research and development. The Keysight 53210A HF frequency counter meets the requirements with its high accuracy, bandwidth and speed. Depending on the application and budget, choose one of the three available models. The connection to the PC is via USB, Ethernet/LXI or via GPIB.
-
Product
0.1Hz-3.7GHz Frequency Counter
FC-3000
-
Features:*Frequency measuring range: 0.1Hz to 100MHz in A input, 80 MHz to 3.0GHz in C input.*Period,Total and RPM measurement for input A*9 Digit display with 0.01mHz resolution in 1 Sec (By Ext.Reference signal).*RS-232C serial interface function for communication with computer.*High sensitivity Extemal reference input function(>=1.5Vrms).*Peciprocal technique for high resolution at low counting frequencies .*Self check function executed to perform a automatic self diagnosis of various counter function.*Push-scanning for selecting Function and Gate time.*Low-pass filter(100KHz,-3dB)installed for removing noise signsl in low frequency measuring.*AC/DC coupling function(Selectable AC/CD Coupling)*10:1 Input Attenuation(Selectable×1/×10 Attenuator)*Data hold function
-
Product
110 GHz Frequency Extender
N5293AX03
Frequency Extender
The N5293AX03 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
Product
Frequency Meter, 3.7 to 12.5 GHz
537A
Frequency Counter
The Keysight 537A direct-reading frequency meter measures frequencies from 3.7 to 12.5 GHz quickly and accurately. Its long scale length and numerous calibration marks provide high resolution. This is particularly useful when measuring frequency differences or small frequency changes. Frequency is read directly in GHz so interpolation or charts are not required.
-
Product
NI-9361, 32-Bit, 8-Channel C Series Counter Input Module
783407-02
Counter Input Module
32-Bit, 8-Channel C Series Counter Input Module - The NI‑9361 is a differential or single-ended input module. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. You can also directly connect sensors with open-collector or push-pull outputs by using an internal switchable 1 kΩ pull‑up resistor. The NI‑9361 counters can perform encoder position and velocity measurements. You can synchronize the counters with other analog, digital, and counter measurements in your chassis.
-
Product
120 GHz Frequency Extender
N5295AX53
Frequency Extender
The N5295AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
Product
120 GHz Frequency Extender
N5295AX03
Frequency Extender
The N5295AX03 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
Product
40-72 GHz Doubler
1GC1-8048
Frequency Extender
The 1GC1-8048 is a balanced diode frequency doubler consisting of two Schottky diodes and a coplanar balun structure. The doubler provides 15 dB conversion loss and 17.5 dBc 1st and 3rd order feed-thru for input frequencies between 20 and 33.5 GHz. This IC is fabricated in HFTC's InGaP/GaAs heterojunction bipolar transistor (HBT) process that provides excellent uniformity, reliability and 1/f noise performance.
-
Product
DC - 12 GHz High Efficiency GaAs HBT MMIC Divide by 4 Prescaler
HMMC-3024
Frequency Divider
The HMMC-3024 is a DC - 12 GHz divide by four pre scaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
Product
350 MHz Universal Frequency Counter/Timer, 12 digits/s, 100 ps
53220A
Frequency Counter
Two 350 MHz input channels, plus optional third channel (6 GHz or 15 GHz)12 digits/second resolution, 100 p sec time interval resolution LXI-C/LAN, USB, GPIB Built-in math analysis and color, graphical display (trend and histogram)Optional: Lithium Ion Battery Bench Vue software enabled: Do more with your PC and instrument together, no programming required. Easily control your counters, quickly build automated tests and log data for faster analysis and save precious time.
-
Product
RF High Frequency Probes
High Frequency Probe
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
Frequency Extender
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
120 GHz Frequency Extender
N5295AX51
Frequency Extender
The N5295AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
Product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
High Frequency Probe
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
110 GHz Frequency Extender
N5293AX51
Frequency Extender
The N5293AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.