Thermocouples
Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.
-
Product
Thermocouples With Terminal Heads
-
Thermocouples with Terminal Heads including Mineral Insulated, Industrial Style & remote wall mounted housing thermocouples.
-
Product
Thermocouples
-
Watlow Electric Manufacturing Company
Thermocouples are best suited for high temperatures, extreme environments or applications requiring microscopic size sensors.
-
Product
Exhaust Gas Thermocouples
8TR4C Series
-
The AMETEK 8TR4C Series Exhaust Gas Thermocouples for Frame 7 and 9 applications have been designed, fully tested, and qualified to meet OEM specifications. AMETEK has worked closely with the OEM turbine manufacturer to qualify and engine test this thermocouple as a direct replacement, or for upgrading older style Exhaust Gas Thermocouples.
-
Product
Exhaust Gas Thermocouples
HYBRID Series
-
The AMETEK Hybrid Series Exhaust Gas Thermocouples for Frame 7 and 9 applications have been designed, fully tested and qualified to meet OEM specifications. AMETEK has worked closely with the OEM turbine manufacturer to qualify and engine test this thermocouple as a direct replacement, or for upgrading an older style Exhaust Gas Thermocouple.
-
Product
K-Type Thermocouples Wire, Fiberglass (32 deg F to 900 deg F) 1 m
745690-K001
-
K-Type Thermocouple, 32°F to 900°F Temperature Sensor - The K-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the K-Type Thermocouple and acquire synchronized temperature data in units of degrees. The K-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
8 Inputs Temperature Data Logger – Thermocouples
HD32.8.8
-
Rugged data logger with 8 inputs for K, J, T, N, R, S, B and E type thermocouple with miniature connector temperature probes.
-
Product
Thermocouple 90 Series Modules
-
VPC offers a wide array of modules with a variety of connection options that are configurable for virtually any interconnect requirement.
-
Product
Thermocouple Calibrators
-
Practical Instrument Electronics, Inc.
PIE has a thermocouple calibrator to fit your needs from the PIE 520B single type thermocouple simulator to the advanced troubleshooting capabilities of the PIE 422Plus. Have you had issues in the past where your thermocouple calibrator wouldn’t work with some of the instruments in your plant? Our thermocouple calibrators are guaranteed to be compatible with all process thermocouple inputs including all brands of smart temperature transmitters, PLC input cards, DCS systems and multichannel recorders.
-
Product
Digital Thermometer with K Type Thermocouple Sensor
Model 300
-
this thermometer is a digital hermometer fr use with any K-type thermocouple as temperature sensor. temperature indication follows IEC584 temperature/voltage tables for K-type thermocouples.
-
Product
Thermal Profiler
MEGAM.O.L.E.® 20
-
Do you demand the highest density of thermocouples placement possible on your Hi-Reliability, High-Value PCB? ECD's got your Spec! Do you expect a software package that flexes with your workflow, providing customizable data extractions, Imports of your .MDM M.O.L.E. libraries and compatibility with your intranet, Excel, and all ECD M.O.L.E. profilers?
-
Product
5 ½ Digits Dual-Display Digital Multimeters
SDM3055
-
The SIGLENT SDM3055-SC includes a multiplexer that provides multi-point measurement capabilities. The scanner features 12 multi-purpose + 4 current channels and supports the following measurement functions: DCV, ACV, DCI, ACI, 2WR, 4WR, CAP, FREQ, DIODE, CONT and TEMP (RTD and Thermocouple ). It provides a convenient and versatile solution for test applications that require multiple measurement points or signals and is an ideal tool for R&D burn-in and production testing.
-
Product
Vacuum Gauge Controllers
-
MKS offers a range of controllers that control ion gauges, heat-loss sensors, and thermocouples. Product features can be configured to meet your specific process needs. A variety of communication protocols, including RS-232, RS-485, and DeviceNet™, are available to speed and ease integration into your control scheme. In addition, many of the controllers provide local displays and a choice of set points that further simplify control system integration.
-
Product
Process Calibrators
-
AMETEK Sensors, Test & Calibration
Our process calibrators include innovative handheld multifunction calibrators, multi-channel scanners, and handheld loop calibrators and power sources. Our multifunction calibrators feature a new large full color display with an advanced simplicity, easy-to-use interface. The multi-scanner is perfect when there is a need to create traceable documents for sensor calibrations. Calibrate 16 types of RTDs, and 13 types of thermocouples with our handheld calibrators.
-
Product
MAX31855 K-Type Thermocouple Sensor Breakout
SEN-30001-K
-
Breakout board for the MAX31855K digital thermocouple interface IC. Measured temperature range is -270C-1372C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 1x5 pin header, has a vertical mini thermocouple connector and four mounting holes for standoffs and 4-40 screws.
-
Product
30:1 Spot IR Thermometer with Type K Thermocouple
FLIR TG56
-
The FLIR TG56 provides non-contact surface temperature readings so you can quickly and easily take measurements in places that are out of reach. Providing a distance-to-spot ratio of 30:1, the TG56 can measure smaller targets from a safer distance. The thermometer gives you control to view your current reading and last two temperature readings simultaneously, and the color screen makes it easy to navigate and select settings.
-
Product
Isolated Precision Thermocouple LXI Instrument
ProDAQ 6150
-
The ProDAQ 6150 is an LXI instrument designed for up to 48-channel isolated precision thermocouple measurements. It supports all common thermocouple types, namely J, E, N, K, T, R, S and B as well as custom types via a programmable conversion. Each channel is isolated from both the chassis and all other channels.
-
Product
Two Inputs Thermocouple Thermometer
HD2328.0
-
Thermocouple thermometer for probes type K, J, T, E. It measures temperature by means of immersion, penetration, contact or aria probes. Two inputs for miniature thermocouple connectors. Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree.
-
Product
Thermocouple Cable / Wire
-
Labfacility offer a wide range of thermocouple, PRT and extension cable / wire in stock for immediate despatch. Thermocouple cables are available in IEC or ANSI colour codes. Insulation types include PFA, PTFE, PVC & Fibreglass.
-
Product
Multiplexed- Low-Level Function Card
-
Low-level multiplexed systems have a single programmable gain, wide-band amplifier following the input multiplexer. To accommodate low-level signal signals such as those from strain gauges or thermocouples and at the same time high level signals from other sources, the throughput rate must be limited to enable the high bandwidth amplifier to settle to the correct value after switching to a new channel. This results in a relatively low aggregate throughput rate when compared to an amplifier-per-channel system. A major benefit of a well designed low-level multiplexed system is the extremely high performance/cost relationship.
-
Product
External Double Way Temperature Datalogger
VA602-TK-TJ
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Two tunnel data logger with voltage current temperature (thermocouple) K.J.PT type, with USB, up to 16000 data record point.
-
Product
Gauge Type T Thermocouple Wire
W-TW-36P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
MAX31856 Thermocouple Sensor Arduino Shield
SEN-30007-T
-
Quad channel thermocouple Arduino shield based on the MAX31856 universal digital thermocouple interface IC. This is an exciting update of the MAX31855, with improvements in resolution (19 vs 14 bits), on-board temperature reference (6 vs 4 bits), and compensation (fully compensated vs nonlinear correction required). The MAX31856 is interfaced via 4-wire SPI with options for interrupt triggering. An LDO and a high-speed level shifter are included on ALL device pins to allow interfacing with to any Arduino - both 3.3V and 5.0V variants - without sacrificing device performance in any operating condition.
-
Product
K Type Thermocouple Universal Probe
-
Suitable for quickly measuring air,gas. Not suitable for liquid.
-
Product
Multifunction Process Calibrators
-
AMETEK Sensors, Test & Calibration
Our multifunction process calibrators read and source RTD, thermocouple, current, voltage, frequency, and resistance to calibrate or verify your process sensors. They can also be combined with APM CPF pressure modules to calibrate pressure, or a dry-block to calibrate temperature. The ASC-400 features a large full color display with an advanced simplicity, easy-to-use interface.
-
Product
FD-11613, 8-Channel Temperature Input Device for FieldDAQ
785640-01
-
8-Channel Temperature Input Device for FieldDAQ - The FD-11613 measures up to eight thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11613 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11613 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11613 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
Product
Thermometer, -20°C to +400°C, 7.9 ", 2.7 ", 1.2 "
72-6700
-
Infrared Thermometer*Three thermometers in one...Infrared, Pt100 ohm and Thermocouple*Accommodates 4 wire Pt-100 ohm probes and thermocouple types K, J, R, T, and E.*Selectable readings °C or °F*Data Hold function*Min./Max memory function*Laser guide for IR function*RS 232 output*Auto power off
-
Product
8-CH Thermocouple Input Module
ND-6018
-
- Channels: 6 Differential & 2 Single-ended- Input Type: Thermocouple, mV, V and mA- Thermocouple Type: J, K, T, E, R, S, B, N,C- Voltage Range: ± 15 mV, ± 50 mV, ± 100 mV, ± 500 mV, ± 1 V, ± 2.5 V- Current Range: ± 20 mA- Isolation Voltage: 2500 VRMS
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
-
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
K Thermocouple Immersion Probe
TP651_TP652
-
Immersion "K" Type thermocouple probe. °C max: 1200. Response time: 6 s.
-
Product
K Thermocouple Penetration Probe
TP776
-
“K” Type thermocouple penetration probe. Tolerance according to IEC 60584-2 standard.