Current Transducers
-
Product
High DC Primary Current Injection Test Set
PDC15k
-
PDC15k High DC Primary Current Injection Test Set adopts high-frequency invert principle to realize the high DC current output capability, with very small size and light weight. PDC15k is modular designed with changeable modules and multi-functions local control software.
-
Product
Integrated Two-Stage Current Sensors
-
If ultra-low noise performance is required, our integrated two stage devices are the number one choice. With input inductances from 24 nH to 1.8 µH and a flux-noise level as low as 0.8 µPhi0/sqrt(Hz) an energy resolution of about 45 h is attained. The devices consist of a 16 SQUID series array as amplifier stage and a single front-end SQUID.
-
Product
Explosion-Proof Transducer
HX
-
Computer Conversions Corporation
Computer Conversions Explosion-Proof Transducer Housings are designed to operate in hazardous environments requiring an Explosion-Proof Enclosure. Suited with internal (Factory Installed) resolver-transducers; these units can be provided as part of an absolute and/or incremental encoder system. Most transducer cables only require six conductors, shielding is optional, and systems are capable of maintaining 1000' cable runs in severe RFI environments.
-
Product
Primary Current Injection Test Set
T 2000
-
T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.
-
Product
Low Current Probe/DMM
687
-
With the capability of measuring down to 1 milliamp (.001A), the #687 is a great tool for all low current applications. Especially for diagnosing parasitic drains! Clamp opening is large enough to fit over most negative battery cables. Applications: fuel injectors, fuel pumps, electric motors, battery drains, charging systems.
-
Product
AC / DC Current Probe, 2 MHz, 500 Arms
N2780B
Battery Probe
The N2780B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 500 Arms continuous.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-1500B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Self-reclosing Overcurrent And Residual Current Protection
-
Wide range of solutions to guarantee personnel safety as well as maximum service continuity in the event of a ground current or breaker trip, with automatic reconnection of the installation. Available with RS-485 communications (Modbus RTU) and remote control inputs/outputs.
-
Product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
Source Measure Unit
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
Leakage Current Tester
-
Premier's Leakage Current Tester (also known as Hipot Tester) simulates the effect of a person touching exposed metal parts of a product and detects whether or not the leakage current that would flow through the person's body remains below a safe level.
-
Product
HCAI-1 High Current Arc Ignition Tester
HCAI-1
-
The HCAI-1 High Current Arc Ignition Tester is according to IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943.1-2011
and UL746A, IEC60947.1: 1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-2008 and other standards required simulated safety test project. Parts and components of insulating materials or other solid combustible materials that are prone to flame spread in electrical and electronic equipment may ignite due to proximity or contact with electric arc, causing electrical fire and endangering the reliable operation of equipment and personal safety. -
Product
Current Tester
MIG0624
-
The MIG0624 current tester is designed to test surge protection devices for low voltage applications (<1000 V). MIG0624 is a current generator delivering a 8/20 µs impulse up to 24kA. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied.
-
Product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-20M
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement for solar power system*Least affection from the magnetization of core and temperature fluctuation*DC leakage current measurements*Current measurements for small DC motor*Convenient +5V single polarity power supply
-
Product
3-Axis AC Magnetic Transducer
3DACMT-1
-
The *SENIS* 3DACMT-1 is a cutting-edge 3-Axis AC Magnetic Transducer designed for precise measurement of alternating magnetic fields. It operates within a frequency range of 10kHz to 200kHz, making it an ideal choice for applications requiring high sensitivity and precision. The device features a compact sensing cube with a volume of about 3.6 cm³, ensuring non-invasive measurements that do not disturb the magnetic fields being observed. With its exceptional resolution of better than 1.5μTrms, the 3DACMT-1 delivers a highly linear response and transduction accuracy of ±1%, ensuring reliability even in the most demanding environments. Further, the *SENIS* 3DACMT-1's design incorporates three mutually orthogonal coils, allowing it to capture all three components of magnetic fields simultaneously while being insensitive to electrical fields or capacitive coupling. The sensor's excellent angular accuracy of <±1° and phase accuracy of <3° at 85kHz enhances its capability to provide accurate data. Additionally, with an output signal from 0V to ±5V, and a measurement bandwidth of 10kHz to 200kHz, this transducer is built to handle complex measurement tasks efficiently.
-
Product
AC/DC Leakage Current Tester
228
-
Test for dangerous leakage current with the Simpson Model 228, designed to meet the latest UL, IEC, and ANSI specifications. The 228 detects both AC and DC leakage current and simulates human response at three different levels -- reaction, let-go, and burn hazard. Each Model 228 comes with test leads with alligator clips, manual, and batteries.
-
Product
Analog Power Transducers
ROCHESTER
-
AMETEK Power Instruments offers a wide range of Rochester Analog Power Transducers for meeting all of your power measurement needs. The transducers consist of two families of products; the Process and Ultra series. Each one is designed to provide an exact fit for your monitoring application.
-
Product
Thin Film Current Sensing Chip Resistors
CSTN
-
*Thin film process*High power rating up to 3 watts in 2512 size*Resistance values from 50m to 1ohm*High purity alumina substrate for high power dissipation*Power management applications*Switching power supply*Over current protection in audio applications*Voltage regulation module (VRM)*DC-DC converter, battery pack, charger, adaptor,*Automatic engine control*Disk drive
-
Product
AC DC Current and Voltage Converters
-
The DAT5023 I is an AC or DC current converter, the input current range is selectable on order from 0-5Amps, 0-10Amps, 0-20Amps, 0-25Amps, 0-30Amps, 0-40Amps, 0-50Amps, 0-60Amps. It measure the current with the use of a Hall effect transducer. There is a coil (current transformer) inside the current converter which is isolated from the current input. The cable passes through the housing of the converter and the coil and the true root mean square measurement is taken from this coil then converted to a standard industrial signal output.
-
Product
Split Type AC Current Sensor
CTF-6
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*For AC current and power measurements.*Ultra compact size and high accurate output linearity.*Easy installation in the distributing box.*Compliant with RoHS drective.
-
Product
Leakage Current Sensors / Small Current Sensors
-
ChenYang Technologies GmbH & Co. KG
This current sensor is based on magnetic modulation and compensation principle, and can beused for measurement of small DC current and leakage current, current difference between two ormore conductors.
-
Product
High Speed Response, High Accuracy DC Leakage Current Sensor
DCZCT-20CDHL
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Low DC current measurements.*DC1mA~200mA*High accuracy.*±1%F.S ±10mV*Least influence of magnetization.*Less than DC1mA in current level*Convenient +5V single polarity power supply.*Reference voltage (Vref) terminal is equipped.
-
Product
Custom Made Transducers
-
GB Inspection Systems have manufactured bespoke transducers for over 35 years, covering a wide range of applications.From simple contouring of delay line / wedges used on pipe testing or special compact housings to allow easier access to test areas, we can offer solutions for your specific applications.
-
Product
Current Probe
-
Beijing GFUVE Electronics Co.,Ltd.
Used to measure control currents for relays in electronic circuits and in evaluation testing of capacitors' current characteristics.
-
Product
Impulse Semiconductor High Current Integrated
Transmission Line Pulse Test System
-
The Impulse Semiconductor High Current Transmission Line Pulse (TLP) test system is the tool of choice for extracting ESD parameters for transient protection devices in a package, or at wafer level. With accuracy better than 100 milliohms at 40 amps peak current, the Impulse high current TLP is specially tailored to the needs of today's ESD device designers who must accurately measure low values dynamic resistance irrespective of breakdown voltage.
-
Product
General Purpose Pressure Transducer and Transmitter
P55
-
The robust P55 pressure transducer provides cost-effective reliability for severe test environments. With extreme resistance to shock and vibration, the P55 pressure transducer delivers the same high-level performance expected from more delicate differential pressure transducers and pressure transmitters. With variable reluctance sensing technology, the P55 pressure transducer delivers fast dynamic response, high resistance to vibration and superior signal stability through ambient temperature change for a wide variety of low-pressure to high-pressure measurements. The P55 pressure transducer will accept both liquids and gases directly at the sensing diaphragm and there are no internal isolation fluids to slow the sensor response or cause excessive temperature drift errors.
-
Product
AC/DC Current Probe, 100 MHz, 15A
N2893A
Oscilloscope Probe
The Keysight N2893A is a 100 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features flat bandwidth (DC-100MHz), low noise(<2.5 mA rms) and low circuit insertion loss. Auto demagnetization (degauss) and calibration removes any residual magnetism and unwanted DC offset in the probe. The probe is powered directly by the InfiniiVision and Infiniium Autoprobe interface, eliminating the need for an additional power supply.
-
Product
Leakage Current Tester
-
Aarohi Embedded Systems Pvt. Ltd
“ AAROHI” make Leakage current tester is very compact & specially designed microprocessor based instrument to measure mA of motor,Stator.
-
Product
Current Source
M151
-
Clarke-Hess Communications Research
The Model M151 is a stable high current calibrator up to 120 A. Basic accuracy is 0.035 %. It can be controlled viaRS232 or GPIB interface. The Model 151 can function in a simulated amplifier mode to increase the current capabilityof any multifunction calibrator. It is suitable for power meter calibration because it can be synchronized with the inputsignal not only in amplitude but also in frequency and phase. The current terminals are isolated up to 450 Vpk againstcase (protective earth).
-
Product
Current Injection
-
K&S Engineering and Scientific Ltd
The outputs are continuously variable from zero and are all isolated. The current outputs can be used at twice their continuous rated current on a 25% duty cycle with a maximum ON time of 5 minutes.
-
Product
Wireless Transducers with GSM Modem
-
Wireless GSM data loggers for temperature, humidity, binary-u. counter input.