Loop Indicators
See Also: Indicators, Angle Position Indicators, Fault Indicators, Voltage Indicators
-
Product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
-
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.
-
Product
Active Loop Antenna
KH30935
-
Beijing KeHuan Century EMC Technology Co,.LTD
KH30935 active loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna has a small outer diameter and light weight, which is convenient for outdoor measurement.
-
Product
RTD Temperature Indicator
CM2-TR
-
CM2-TR RTD Temperature Indicator has been designed in simple operation and 4 digital 20mm LED display with economic cost.They are can be programmed by buttons that are hidden in front panel.They are also available to option relay output and an analog output or RS485 (Modbus RTU Mode) communication.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
Analog Output Module
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
RS485 Remote Display Indicator
CS1-8
-
CS1-8 has been designed for remote display by RS485 (Modbus RTU Mode) interface.
-
Product
Knopp Phase Sequence Indicator
K-3, K-6, and K-7
-
Use of the Knopp K-3 Phase Sequence Indicator saves man-hours and protects valuable equipment against damage. It pays for itself in a short time. Specially designed induction motor unmistakably indicates the phase sequence by direction of rotation or rotor disc.
-
Product
Flow Indicator
Qualitrol 092
-
Designed to indicate “pump on” and “pump off” conditions within a forced cooling system. Select models also indicate flow direction. Up to two SPST or SPDT switches are available for control and/or alarm functions. Large dial face provides easy viewing and is magnetically coupled to the flange assembly allowing leak free replacement if damaged.
-
Product
Cable Indicators
CableTroll
-
They are installed on Ring Main Units in distribution substations. They are used to detect short circuit and earth faults, and can be installed on most types of cable terminations. Some units will give separate indications for short circuit and earth faults, locally by flashing diodes and remotely through separate relay contacts or additional ComTroll communications modules.
-
Product
Economic Type Temperature Indicator
CS1-T
-
CS1-T economic type Temperature Indicator has been designed with high accuracy measurement, display and communication of Thermocouple or Pt100Ω.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.
-
Product
Antenna, Loop
EM-6874 | 20 Hz – 30 MHz
-
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
Product
Intelligent Transmitter with Digital Indication
LEO 3
-
KELLER AG für Druckmesstechnik
LEO 3 is a micro-processor based transmitter with digital double-display for pressure (top display) and for the output signal (bottom display). The display is powered from the 4...20 mA current loop. Functions:
-
Product
Current Loop Adapter
OP-1C
-
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
Product
Short-circuit and Earth Fault Indicators
-
The Sensorform range of Short-circuit and Earth Fault Indicators detects short-circuit and earth faults on medium voltage underground cables. A wide range of options are available for enclosure type, power source, indicator type, reset method, trip-level selection, auxiliary outputs, and remote indication.
-
Product
PXI Analog Output / Current Loop Simulators
-
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
Product
Load Cell Indicator
-
Morehouse Instrument Company Inc.
This indicator can read mV/V and use free, custom Morehouse software to convert the mV/V units to engineering units with coefficient files from ASTM E74 or ISO 376 reports. This meter is often the choice for accredited calibration service providers that want high accuracy and convenience but do not want to break the bank.
-
Product
Remote Indicators and Control Panels
-
Alarm indicator, operator and display panels form the link between personnel and installed technology. Bender offers innovative operating concepts for safe power supply. From a simple display panel through foil-laminated panels to Control Panels, all modules for providing visual and acoustic information can be integrated into a comprehensive solution and adjusted to the customer's requirements.The portfolio contains solutions tailored to the needs of specific sectors, such as hospitals and medical locations.
-
Product
Speed Indication & Sensing
-
Provide an accurate speed display at an economical cost. Available with Digital or Analog displays in both a panel and base-mount enclosure. Each maintains the reliability and rugged performance customers expect.
-
Product
3-Dimensional Loop Antenna Van Veen
-
Loop Antenna System ( LAS )3-dimensional large loop antennadiam. 2 macc. EN 55015 / CISPR 15
-
Product
Lipo Battery Power Level Tester & Alarm to Indicate Low Power
#52023
-
Can be used for 7.4V (2S pack)and 11.1V (3S pack).Red LED will flash when cell is below 3.3V and an Alarm will sound when cell is below 3.0V indicating the Lipo Battery pack should be recharged.
-
Product
Rain Indicator Data Logger
HD2013-DB
-
Rain indicator Data Logger with LCD display; reads and stores up to 32,255 pulses coming from a rain gauge with tipping bucket.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
Product
Self Testing Clamps with Visual Indication
Bond-Rite REMOTE
-
As an alternative to the standard Bond-Rite, a ?remote? version is also available. In this configuration, the Intrinsically Safe monitoring electronics, flashing green LED and battery power supply are housed inside a tough, corrosion resistant stainless steel enclosure, designed for wall mounting. An insulated stowage point, for the safe return of the clamp when not in use, is included.
-
Product
Dial Indicators
-
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
Product
Indicators
-
Weighing indicators and controllers are used for a range of applications, from simple weight displays and data collection to control of an entire automated process. These instruments may add precise amounts of multiple ingredients to a batch recipe formulation, turn on a motor, start a conveyor, or provide data for inventory management and traceability. Programmable software is usually included. VPG Transducers also offers a wide range of junction boxes, which are an integral part of any weighing system.
-
Product
Phase Sequence Indicators (Contact Type)
888 PMR
-
Standard Electric Works Co., Ltd
● Indicates phase rotation. ● Indicates phase presence.● Indicates motor rotation/wiring.● Indicates battery status.● Phase rotation and motor rotation indication works from as low as 1Vac.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 100 Vac. ● Very low consumption.● Fused. ● Lightweight, robust and compact.● Works from 2 Hz to 400 Hz Sine.
-
Product
Flow Indicators
-
Flow indicator with rotor features a self-cleaning mechanism to ensure full visibility of the rotor at all times. Typical sight flow indicators suffer from poor indicator visibility through normal use from build-up that impedes observation of the rotor through the viewing window. Typically, for a sight flow indicator to be cleaned, it must be removed from the pipeline, cleaned and then replaced at some specified time, such as during plant shutdown. Unfortunately, dirt build-up does not typically schedule itself to correspond with planned shutdowns. Enter the KOBOLD DAA Series flow indicator. Simply twist the sight glass and the integral wipers clean the flow indicator's viewing area to allow unobstructed observation of the rotor. The offending contaminants are then simply washed away by the media flow. This process may be repeated as often as desired with no fuss and no downtime. The DAA is available with brass or stainless steel fittings with " to 1" NPT female threads. The DAA is also available without a rotor for observation of fluid condition.
-
Product
Vertical Speed Indicators
-
Is an instrument which indicates the rate of climb or descent of an aircraft.
-
Product
4 Digit Field Indicator
CFIA-40 4
-
1. Using LED to display, and able to be used in dark environment2. No external power needed3. Able to display measured value like pressure , temperature and depth etc4. Display solution 1/99995. Isolated alarm open drain output6. Voltage drop will below 4 volt
-
Product
Loop Powered Trip Amplifier With Dual Relay Output
SEM1636
-