Primary Current Injection Test
-
product
High Current Calibrator
MC151
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
product
Current Generator
MIG12100
MIG12100 is a current generator with wave shape 8/20 ìs. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied. The generator can deliver up to 100kA impulse current supported by 12kV impulse voltage, making it ideal for testing big varistors with high hold-on voltage. Mechanically the MIG12100 consists of two large racks and a separate control console with high voltage output terminals protected by a glass acrylic test cabinet.
-
product
Current Probe
Beijing GFUVE Electronics Co.,Ltd.
Used to measure control currents for relays in electronic circuits and in evaluation testing of capacitors' current characteristics.
-
product
DC Current Bias Supply
DC1000A
To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.
-
product
Magnetic & Current Sensors
From the International Space Station to a simple electronic compass, we can provide a solution to meet your magnetic semiconductor needs. The F.W. Bell® product line was founded in 1944. Since then we have been a pioneer in developing instrumentation to measure electric current and magnetic fields.
-
product
Current Logger0 to 25mA DC
TV-4804
The TV-4804 measures current from 0 to 25mA DC and can be connected to a variety of industry standard sensors enabling the logging of a wide range of process parameters.
-
product
Current Sense Magnetics
Current sense magnetics are used as a low loss method for sensing AC current in a circuit and also provide electrical and safety isolation between the source of the current and the measurement circuit. The key parameters for a current sense transformer are the rms current rating (to ensure it does not overheat in the application) and the safety and voltage isolation (to ensure it conforms to the end-application requirements).
-
product
30 A Current Shunt
34330A
Measure current safely with this precision 0.001 ohm resistor housed in a plastic case surrounded by epoxy.
-
product
Leakage Current Tester
Premier's Leakage Current Tester (also known as Hipot Tester) simulates the effect of a person touching exposed metal parts of a product and detects whether or not the leakage current that would flow through the person's body remains below a safe level.
-
product
Current Probe
DCP-BTA
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
product
High Speed Test Bench
AT444
AC motor with mechanical multiplying gearbox test benches allow precise programming of all drive parameters required for accurate rotating devices test.The use of special high-speed bearings, mechanical components and parts wear resistant leads to a large life. The supply includes the electronic drive and control as well as the entire oil cooling unit.
-
product
Current Probes
Tektronix current probe solutions offer:*The broadest range of AC/DC and AC-only current probes*Measurement accuracy from uAs to 2000 A*Best-in-class bandwidth up to 120 MHz*Best-in-class current clamp sensitivity down to 1 mA*The only products with 3rd Party Safety Certification (UL, CSA, ETL)*The only products with bare wire voltage ratings*Automatic readout and scaling when used with Tektronix oscilloscopes so you don’t have to convert volts to amps or manually set the scaling
-
product
Current Transformer
LTTJ
Love Controls LTTJ Series Current Transformers allow easy monitoring of the current flowing to your load. This easy to use device provides a 0 to 10 VDC signal into both low and high impedance circuits, and is easily scalable to your needs
-
product
DC Bias Current Source
TH1778AS
Changzhou Tonghui Electronic Co., Ltd.
■ Test Frequency: 0Hz - 2MHz ■ Provide 0~20A of constant current output, and must be controlled by TH1778A ■ Support 6 machines on line at most and
-
product
Resistive Current Tester
Weshine Electric Manufacturing Co., Ltd
Long Distance Digital Zinc Oxide Arrester Resistive Current Safety Testing Set
-
product
Dytronic Primary Transfer Ultra Stable Standard
RD-22 Ultra
The RD-22 Dytronic Primary Transfer Ultra Stable Standard represents the state-of-the-art technology in a commercially available AC transfer reference. The Ultra Stable RD-22 is a variant of the RD-22 Primary Transfer Standard that has been optimized for 120/240 V @ 5A operation to provide optimum stability. In a stable test environment, repeatability for a 10-second test of ±0.6 µWh/VAh is attained at 120 V and 240 V at 5A inputs with a 95% confidence interval. A typical experimental 2 repeatability of less than ±0.25 µWh/VAh is achieved. In a stable test environment, a reproducibility of ±2 µWh/VAh over a five-day interval is attained at 120 V and 240 V at 5A inputs with 95% confidence interval.
-
product
In-Line 2-Module In-Circuit Test System; i337x, Series 5i
E9988E
Short wire fixturing eliminates problems commonly found with long wire fixturing, such as noise and deterioration of test stability. This translates into transportable, repeatable and stable tests on your i3070 Series 5i, even if you need to deploy tests halfway across the globe, or on different manufacturing sites.
-
product
Image Sensor Testing
IP750Ex-HD Family
The IP750EX-HD has been the test platform that has enabled the industry to manufacture high quality CCD and CMOS image sensors, and it is the most economical platform to meet the needs of newer technologies such as Time of Flight (ToF) sensors. When you use a smartphone, high performance digital still camera, or in-home security and surveillance system, these applications have image sensors most likely tested by Teradyne’s IP750ExHD.
-
product
OEM Current Input0 to 20mA
TGPR-0800
A current input data logger that is supplied uncased so that it can be built into custom applications.The TGPR-0800 can be used to record the output from a number of industry standard 4-20mA sensors. Common applications include pressure and flow rate monitoring.
-
product
Split Core Current Transformers
Application:Watt Transducer, Current Transducer, KWH Meter, Demand Meter, Power Factor Meter, Current Sensing Relays, Energy Management SystemsContinuous Thermal: Rating 1.25 at 30° C, 1.0 at 55° C Standard 5-amp secondary. Others available.
-
product
Precision Current Shunt
Has five precision selectable Ultra stable Current Shunts which ranges from 0.0001 to 1Ω. The Shunt T/C is less than 10ppm, and the internal current meter will measure from 1μA to 1000Amps.
-
product
Current Transformer with Open Core
TCP
Lifasa - International Capacitors, SA
The TCP series is designed for installations in operation. It has a removable core that allows its connection without interrupting the power supply.
-
product
Scalable Tester System for Functional Testing
UTP6010
The UTP6010 is a scalable tester system for functional testing, comprising an integrated main switching unit, a keyboard drawer and a swivelling monitor. It is the reliable, modular, low priced UTP starter kit. The system is suitable for tester applications, where space-saving devices are required, because its construction height is only 12 HU (excluding keyboard drawer and main switching unit).
-
product
Extra-Ground Current Impuision Equipment
JYQ
Generally, the way of finding out the iron core ground false of powertransformer is always inefficient, while the method of using the traditional measure such as increase powerful current by welder when finding the false point oftransformer. The transformer needs to be mended on the spot or return to the factory if it can not melt off the point because of low voltage. It will spend high transportation fee and dealing costs, brings huge economic loss. The JYQ iron-coreimpulsionequipment is the intelligence set for exclusiveusing in solving the false of transformer. It can output high-voltage powerful current transientand melt the ground point off rapidly.
-
product
High Voltage Probes To Measure Primary Waveforms With A Power Analyzer
Volt Litewire
The Litewire is a true RMS meter designed for use by electric utilities to sense currents or voltage waveforms from the primary side of their distribution networks.
-
product
High Frequency Current Transformer
HFCT Ø 140mm
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
product
DC Bias Current Source
TH1778B
Changzhou Tonghui Electronic Co., Ltd.
■ Test Frequency: 0Hz - 2MHz ■ Provide 0~20A of constant current output ■ No support of output extension
-
product
Programmable ProBus Current Adapter
CA10
The CA10 is a programmable and customizable interface device that seamlessly incorporates third party current transducers/transformers with Teledyne LeCroy oscilloscopes or motor drive analyzers. It allows the third party device to be recognized and operate as if it were a Teledyne LeCroy probe.
-
product
Dual Surge Current Generator
MIG0624T-K12
Designed for testing telecom surge protection devices according to ITU-T K12. The generator has two indepedent impulse outputs which allow testing of two and three terminal protection devices such as gas discharge tubes (GDT). The generator can be configured for two terminal devices or with the outputs in parallel to increase the current impulse for two terminal devices.
-
product
AC Current Clamp Adapter
LAD-800
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Selectable CT ratio 10:1 and 100:1.●φ80mm CT window, possible to measure from leakage to big current up to 1000A.