Transfer Standards
-
Product
PXI/PXIe Microwave Transfer Switch, Single, 18 GHz, 50 Ω, SMA, Failsafe, Remote Mount
42-782B-521-E
Switch Module
The 40-782B-521-E (PXI) and 42-782B-521-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 18 GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
Product
Digital & ARINC Standards Display Panel
TA-3001
-
This is our soon to be introduced Digital Standards Panel. (2ND QTR) This panel is available with or without a Precision Resolver drive. Included on the panel are four digital displays; TA-902 API, TA903-01 OBI, TA903-02 Distance and a TA903-03 serial distance display. This panel when paired with the TA-3000 GPS/FMS test panel will make one of the most capable testing solutions available today
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T24-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I35-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1W1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2D
General Purpose Probe
Current Rating (Amps): 5Average Probe Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64Resistance (mOhm): 35
-
Product
Standard Gain Horn Pyramidal Horn Antenna
-
Elva’s SGPH series of standard gain horn antennas cover the frequency range of 18 to 220 GHz in ten waveguide bands. They can be issued with rectangular or circular waveguide. Lens technology significantly allows decreasing mechanical sizes of horns and correcting beam for the best performance. These horns are ideal solution for measurement gain of other antennas, short range radars and radiometers.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I40-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Voltage 37 Pin D-Type Cables - Connector to Unterminated
-
The connector to unterminated cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I8-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1B-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.00 (28.00) - 2.30 (65.00) Non Replaceable General Purpose Probe
P2532-1
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 156Test Center (mm): 3.96Full Travel (mil): 139Full Travel (mm): 3.53Recommended Travel (mil): 93Recommended Travel (mm): 2.36Overall Length (mil): 812Overall Length (mm): 20.62Rec. Mounting Hole Size (mil): 94.5Rec. Mounting Hole Size (mm): 2.40Recommended Drill Size: #41 or 2.40 mm
-
Product
Standard Optical Interleaver
-
An innovative technique for expanding the number of channels per fiber involves an optical device, called an optical interleaver. For example, in most DWDM equipment, the standard channel spacing is 100 GHz. But spacing the signal-carrying frequencies every 50 or even 25 GHz can double or even quadruple the number of channels per fiber. This job is accomplished by an optical interleaver. Such a device takes two multiplexed signals with 100-GHz spacing and interleaves them, creating a DWDM signal with channels spaced 50 GHz apart. The process can be repeated, creating even denser composite signals with 25-GHz or 12.5-GHz spacing. The signals at the receiving end are recovered with the same devices used as splitters or optical de-interleavers. Thus, devices and/or networks can be upgraded without requiring that all devices be upgraded, or network bandwidth can be increased.
-
Product
Standard Gain Horn Conical Lens antennas
-
Elva’s SLHA series of standard gain horn lens antennas cover the frequency range of 18 to 220 GHz in ten waveguide bands. They can be issued with rectangular or circular waveguide. Lens technology significantly allows decreasing mechanical sizes of horns and correcting beam for the best performance. These horns are ideal solution for measurement gain of other antennas, short range radars and radiometers.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1J
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-8
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Primary Standard Capacitors
GenRad 1404 Series
-
The GenRad 1404 Series standard capacitors are the standard of choice in metrology labs, and still used today by standards bodies around the world. These capacitors have been designed as primary reference standards of capacitance with which working standards can be compared.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1V-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25C-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1R1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62H-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF800
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation ofpower factor in low voltage instalations
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25Z-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Clamp-On Ultrasonic Transmitter
KATflow 100
-
The KATflow 100 is a compact clamp-on ultrasonic flow transmitter with a robust and practical design for permanent installation and flow measurement on single pipes.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1H-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
IEC Standard Burden Sets (Current)
IEC Burden Sets
-
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
Product
450MM 18In Digital Level Bevel Gauge w/ LCD Backlight Screen, Magnets, Level Bubbles, IP54 Standards
DL400
-
Advance Plus Trading Co., Ltd.
Model Number: DL400 Key Specifications/Special Features: 450MM 17.7INCH Digital Level with level bubbles, strong magnets,LCD bright backlight display, IP54 standards 1. 450mm 17.7 inch level with 2 bubbles, 450*28*64mm(L*W*H), net weight: 430g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13. With strong magnets in the bottom;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
Standard Digitizer
725S Family
-
The 725S family is a digitizer capable of recording waveforms along with performing advanced algorithms for online digital pulse processing (DPP). Utilizing DPP Firmware, users can acquire quantitative physical parameters (Integrated Charge, Pulse Shape Discrimination with very fine time resolution, Pulse Height Analysis) as well as read out waveforms with automatic pulse identification and baseline suppression on channel basis (Zero-Length Encoding and Dynamic Acquisition Window). The wide range of DPP algorithms supported by the 725S make it a “must-have” for any type of nuclear physics application.