Remote Terminal Unit
Collects data from data acquisition (DAQ) devices and transmits the information to the main test system via a network.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP10T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-788-121-TE
Multiplexer Module
The 40-788-121-TE (PXI) and 42-788-121-TE (PXIe) are single failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 40 GHz, 50 Ω, SMA-2.9, Remote Mount, Failsafe
42-784B-043-E
Multiplexer Module
The 40-784B-043-E (PXI) and 42-784B-043-E (PXIe) are triple failsafe SP6T 40 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
LXI Trigger Bus Terminator
ProDAQ 8037
-
The ProDAQ 8037 LXI trigger bus terminator connects to the ProDAQ 6100 LXI function card carrier or the 3030 PCI Express VXIbus slot-0 interface and to any LXI trigger bus wiring or daisy-chain configuration. The die-cast connector ensures a stable connection and prevents accidental disconnects.
-
Product
Multifunction Unit - Up to 80 Channels of Digital I/O for Observing and/or Recording 16 to 64 Channels of Pressure of Temperature
Trig-Tek™ 260B
Multifunction I/O
Delivers up to 80 channels of digital I/O for observing and/or recording 16 to 64 channels of pressure or temperature. Consists of a motherboard that connects up to four daughterboards to the IP 1553 serial bus.
-
Product
Attenuation Control Unit, DC to 18 GHz, 0 to 121 dB, 1-dB Steps
J7201B
Attenuator
Designed for WLAN and WiMAX™ device manufacturing test and mobile handset base transceiver station (BTS) handover test.
-
Product
PXI/PXIe Microwave Relay, Single SPDT, 50GHz, 50Ω, SMA-2.4, Remote Mount
40-780B-551-E
Relay
The 40-780B-551-E (PXI) and 42-780B-551-E (PXIe) are single SPDT 50GHz unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67GHz in 50Ω or 2.5GHz in 75Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50Ω and 1.6/5.6 in 75Ω versions. Remote versions can support up to three SPDT relays in a single slot.
-
Product
Single 8 to 1 Terminated 50 600MHz PXI RF Multiplexer
40-763-001
Multiplexer Module
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
PXI Hex SPDT RF Switch 6GHz 50 SMA Terminated
40-880-003
Switch Module
A range of 50Ω SPDT RF switching with automatic termination of unused signals. Available as a dual switch in a 1 slot PXI module, a quad switch in a two slot PXI module or hex and octal switches in three slot PXI modules.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 50 GHz, 50 Ω, SMA-2.4, Terminated, Failsafe
42-785C-452-T
Multiplexer Module
The 40-785C-452-T (PXI) and 42-785C-452-T (PXIe) are dual failsafe SP4T 50 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP10T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
40-788-122-TE
Multiplexer Module
The 40-788-122-TE (PXI) and 42-788-122-TE (PXIe) are dual failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI/PXIe Microwave Transfer Switch, Single, 40 GHz, 50 Ω, SMA-2.9, Failsafe, Remote Mount
40-782B-541-E
Switch Module
The 40-782B-541-E (PXI) and 42-782B-541-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 40 GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
Product
Conventional Panel-mounted Type Power Amplifier Control Unit
PAT01
-
PAT01 is a power amplifier control unit that controls timing output and reference signal test source for power amplifier.
-
Product
Land Platform Inertial Navigation Unit
Epsilon™
-
Versatile, Epsilon™ family provides advanced applications, even in GNSS denied environment: navigation (position & heading), aiming aid, driving aid. It covers all tactical applications from logistic to infantry fighting vehicles, as well as main battle tank.- Can be integrated with small artillery caliber to provide precision pointing- Connectable to any Battle Management system- Immune to magnetic disturbances
-
Product
PXI Dual Microwave SPDT Relay 18GHz 50 SMA - Internal Termination
40-781-022
Relay
This dual microwave SPDT relay module is part of the 40-781 range that consists of one or two changeover switches capable of switching frequencies to 18GHz in 50 Ohm. Versions are available with either internal or external terminations and connections are made via front panel mounted high quality SMA RF coaxial connectors.
-
Product
PXI Dual 4 to 1 RF Multiplexer 3GHz 50 Ohm SMB Terminated
40-876-002
Multiplexer Module
The 40-876-002 is a 50 Ohm 4 to 1 RF multiplexer with 2 banks in a single PXI slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40-876 has been minimized by careful attention to the mechanical and electrical design.
-
Product
Remote Particle Sensors
3718-A And 3719-A
-
Kanomax Remote Particle Sensors with analog output are designed to fit into your existing monitoring system, or they can be used as a stand-alone unit to monitor a critical area when connected to an alarm or controller. With two models available, these 2-channel remote particle sensors are capable of Modbus communication via RS485 interface. 0.1 cfm and 1.0 cfm flow rate models are available, along with flexible 4-20mA analog output with the 1.0 cfm unit (only).
-
Product
Remote Indicator System
LineTroll R110CQ
-
The fault indicator use a 2.4GHz ISM band short-range radio to communicate with the collector mounted on the pole. The collector communicates with up to 9 fault indicators. Both the indicators and the collector are powered by long-life lithium batteries for long and maintenance free operation.
-
Product
Emergency Power Supply Units (EPSU) (14) 5-15R 1U/0U V/H
EPS-1415-HV
-
EPSU Power (Basic / Surge / Metered / Value) – rack mountable power distribution, 120V, optional surge suppression, and amp meter
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 26.5 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
40-788-041-TE
Multiplexer Module
The 40-788-041-TE (PXI) and 42-788-041-TE (PXIe) are single failsafe SP8T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI/PXIe RF Switch, Quad SPDT, Terminated, 8GHz, 50Ω, SMA
42-880B-002
Switch Module
The 40-880B-002 (PXI) and 42-880B-002 (PXIe) are quad SPDT 50Ω RF switches with 8GHz bandwidth. The 40/42-880B range has automatic termination of unused signals and are available as a dual switch in 1 slot, a quad switch in two slots or hex and octal switches in three slots.
-
Product
16-Ch IDI & 16-Ch Relay EtherCAT Remote I/O Module
AMAX-4862
Motion Controller
Suitable for EtherCAT networks16-ch Isolated Digital Input and 16-ch Form A-type Relay OutputHigh-voltage isolation on input channel (2,500 VDC)Quick removable European type connectorLED indicators for I/O statusSupports EtherCAT Distributed Clock (DC) mode and SyncManager modeTwo rotary switches for up to 256 SubDevice IDs
-
Product
Vehicle Mount Terminals
-
Advantech vehicle mounted computer provides industrial-grade computing solutions for warehouse management systems (WMS), port, construction, heavy-duty vehicle and manufacturing. In addition to excellent computing performance, it also offers flexible configuration and uninterrupted WI-Fi roaming capability to ensure wireless data transmissions.
-
Product
AC Voltage Proving Units
HLV-2
-
Standard Electric Works Co., Ltd
The AC Voltage Detectors and AC Voltage Testers utilized to determine if the devices under test are functionally working. They are not a calibrator and cannot be utilized for calibration.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 26.5GHz, 50Ω, SMA, Remote Mount
40-785C-431-E
Multiplexer Module
The 40-785C-431-E (PXI) and 42-785C-431-E (PXIe) are single SP4T 26.5GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP4T, 67 GHz, 50 Ω, SMA-1.85, Remote Mount, Terminated, Failsafe
40-785C-473-TE
Multiplexer Module
The 40-785C-473-TE (PXI) and 42-785C-473-TE (PXIe) are triple failsafe SP4T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Removable Storage Unit
PXI-DM-U.2
-
The PXI-DM-U.2 PXI Express Storage Unit provides up to 15.36 TB of removable NVME solid state storage (SSD) in a single PXI Express slot. The storage module addresses the requirements of users who need to remove and replace PXI Express storage for security, archival or other reasons.
-
Product
PXI/PXIe Microwave Relay, Single SPDT, 26.5 GHz, 50 Ω, SMA, External Termination, Failsafe, Remote Mount
42-781A-321-E
Relay
The 40-781A-321-E (PXI) and 42-781A-321-E (PXIe) are single failsafe SPDT 26.5 GHz microwave relay modules with external terminations and remotely mounted relays. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 6 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-784B-001-E
Multiplexer Module
The 40-784B-001-E (PXI) and 42-784B-001-E (PXIe) are single failsafe SP6T 6 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
Control Unit
Epec 5050
-
Epec 5050 Control Unit is ideal for applications that require plenty of I/O and enhanced algorithms. Epec 5050 control unit has also a large memory and its I/O is widely programmable. For example, PI pins’ threshold voltage can be selected and many inputs have pull-up/pull-down selection.





























