Thermocouple Calibrators
-
Product
Thermocouple Calibrators
-
Practical Instrument Electronics, Inc.
PIE has a thermocouple calibrator to fit your needs from the PIE 520B single type thermocouple simulator to the advanced troubleshooting capabilities of the PIE 422Plus. Have you had issues in the past where your thermocouple calibrator wouldn’t work with some of the instruments in your plant? Our thermocouple calibrators are guaranteed to be compatible with all process thermocouple inputs including all brands of smart temperature transmitters, PLC input cards, DCS systems and multichannel recorders.
-
Product
Thermocouple Calibration Furnace
9118A
-
The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics.
-
Product
Handheld Calibrators
-
These handheld calibrators are perfect for calibrating thermocouples and RTD's in cases where the sensors are fixed or need to be calibrated on the spot. Locations such as factory floor or in the lab.
-
Product
Signal Calibrators
-
Nagman Instruments & Electronics Pvt. Ltd
If you are looking for Signal calibrators that are best in industry, head over to Nagman website immediately. We have a range of signal calibrators, loop calibrators, milliamp calibrators, process meter and more. Depending on the requirement at hand, you can find a signal calibrator that is best suited for your industry. Signal calibrators can be used for calibrating thermocouples, RTD, transmitters, etc. while loop calibrators are used for calibrating controllers, indicators, etc. Nagman’s range of signal calibrators are handy, light weight, portable and durable.
-
Product
Thermocouple Calibrator
CA10
-
Dual function CA10 Thermocouple Calibrator can be used to source Type K thermocouple output values or measure Type K thermocouples. Quickly select output value using the rotary switch with coarse and fine adjustments.
-
Product
Calibrators
-
Thermocouple temperature calibrator is capable of measuring and simulating up to 8 types of thermocouples (J, K, T, E, R, S, B, N), as well as a voltage in mV.
-
Product
Handheld Calibrators
-
These handheld calibrators are perfect for calibrating thermocouples and RTD's in cases where the sensors are fixed or need to be calibrated on the spot. Locations such as factory floor or in the lab.
-
Product
CALIBRATOR Multi Function Calibrator
MC140
-
The Multifunction Calibrator MC140 functions as a Voltage Calibrator, Current Calibrator, Power Calibrator, Resistance Calibrator, Capacitance Calibrator and a Thermocouple Calibrator.? Having very low uncertainties, it is ideal as a standard of these electric quantities in calibration laboratories.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
-
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
Thermocouple, Contact, Receiver, Alumel, Type K (°C)
610113132
-
Primary mating contact 610113134.Thermocouple contacts are manufactured from chromel or alumel alloys and color-coded for easy identification. Contacts are crimp terminated and easily inserted into the connector module. They can be readily removed from the connector module using a special removal tool.
-
Product
Thermocouple, Contact, Receiver, Chromel, Type K (°C)
610113131
-
Primary mating contact 610113133.Thermocouple contacts are manufactured from chromel or alumel alloys and color-coded for easy identification. Contacts are crimp terminated and easily inserted into the connector module. They can be readily removed from the connector module using a special removal tool.
-
Product
Thermocouple Contact, Receiver, Constantan, Type T (°C)
610113148
-
Primary mating contact 610113149.
-
Product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
-
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
E-Type Thermocouple, 32°F to 900°F Temperature Sensor
745690-E001
-
E-Type Thermocouple, 32°F to 900°F Temperature Sensor - The E-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the E-Type Thermocouple and acquire synchronized temperature data in units of degrees. The E-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Chromel, Type K (°C), Thermocouple Contacts
-
Thermocouple contacts are manufactured from chromel or alumel alloys and are color-coded for easy identification. They are crimp terminated and easily inserted into connector modules and readily removed using a special removal tool.
-
Product
Electronic Calibration Module (ECal), 40 GHz, 2.92 Mm, 2-port
N4692D
-
The Keysight N4692D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4692D is a precision 2-port ECal module that supports 2.92 mm connectors up to 40 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4692D is included for securing your ECal module and accessories.
-
Product
10-meter (33 feet) Sensor Cable
E1739B
-
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
Linear/Angular Measurement Kit
55281B
-
The Keysight 55281B Linear/Angular Measurement Kit is part of the Keysight 5530 Laser Calibration System and enables the system to measure both linear velocity along a machine's travel path as well as rotation about an axis perpendicular to the axis of motion (pitch and yaw).
-
Product
CalPod Drive Cable, 40 GHz, 2 Meter
85553A
-
This cable provides the bias voltages and control signals for operation of the 40 GHz CalPod modules. This cable is supplied with the 85540/41/42A CalPod modules.
-
Product
Sensor Cable, 5 M
E1739A
-
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
Calibration Lead Precision Resistor, Triple
40-975-009-SL3
-
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
Electronic Calibration Module, DC To 6.5 GHz, 2-Port
N7551A
-
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
15-meter (49 feet) Sensor Cable
E1739C
-
The E1739C 15-meter (49 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System. Other cable lengths available: E1739A 5-meter (16 feet), E1739B 10-meter (33 feet) and E1739D 25-meter (82 feet).
-
Product
CalPod Drive Cable Extension, 10 Meter
85554A
-
85554A CalPod Drive Cable (10 meter length) extends the length of CalPod control cables when the distance between the 85523B to the CalPod modules is >2 m.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, Type-N, 2 Port
85092D
-
The Keysight 85092D RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Electronic Calibration Module (ECal), 26.5 GHz, 3.5 Mm, 2-port
N4691D
-
The Keysight N4691D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4691D is a precision 2-port ECal module that supports 3.5 mm connectors up to 26.5 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4691D is included for securing your ECal module and accessories.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (m)
85562A
-
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 26.5 GHz, Type-3.5 Mm (m) 50 Ohm
85520A
-
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
-
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.





























