Patient Simulators
generate known values for any or all of the following medical equipment which measure: invasive blood pressure (IBP), Arrhythmias, Respiration, temperature and Fetal simulation.
-
product
Patient Simulators
Patient simulator enables you to complete preventive maintenance testing with one device in less than five minutes, reducing average test time by up to 88 %. The ProSim 8 patient simulator is also ideal for design engineers looking for a known physiological signal output.
-
product
Multi-Parameter ECG Patient Simulator
SL-8 SimSlim®
The smallest, comprehensive multi-parameter patient simulator on the market. Includes ECG, Respiration, Arrhythmia, 4-IBP, YSI 400/700 Temperature, and Cardiac Output. Its patented power circuitry provides amazing battery life up to 10 years without charging or changing batteries! One button operation reduces the time for setup and completing testing. View the product manual on our User Manuals page.
-
product
Educational Patient Simulator
EasySim®
The new and improved EasySim® arrhythmia simulator fits in the palm of your hand! The ultra-portable (6.6″ x 2.4″ x .5″), ultra-lightweight (10 oz.) remote control will place you on the leading edge of medical education technology. The highly intuitive design features 48 direct-access keys in a remarkably easy to use format. No codes to memorize! No fuss to set up!
-
product
Patient Simulators
Patient Simulators - also known as physiological simulators are essential tools for biomedical personals to accurately test and verify the performance of patient monitoring systems such as cardiac monitors, ECG machines. It simulates physiological parameters such as ECG, arrhythmia waveforms, blood pressure, respiration, temperature.
-
product
Patient Simulator
PatSim200
Designed to make every patient simulation, quicker. Unlike other Patient Simulators, the PatSim uses a home and recall function to easily move between tests and store your most used sequences, no more clicking and scrolling through ‘tree style’ hierarchy to perform each test. Functions: 12 lead NSR ECG simulation, Over 40 selectable Arrhythmias, Performance waveforms, Respiration simulation on lead I & II, Universal temperature simulation, Two channel IBP simulation and Fetal simulation.
-
product
4, 8, 16, 32 Channel ARINC429 Test And Simulation Module For PCI
APXX429-x
ARINC429 Test and Simulation bus interface with 4, 8, 16 or 32 Software programmable Tx/Rx channels plus up to 8 Discrete I/O’s.
-
product
PXI RTD Simulator Module, 24 Channel, PT100
40-263-001
The 40-263-001 is a 24-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 32 Channel
41-761-001
The 41-761-001 is a low voltage 32-channel output module ideal for simulating theoperation of a thermocouple, also available with 24, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
PXI/PXIe Battery Simulator Module, 6-Channel
41-752A-001
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
4, 8, 16 And 32 Channels ARINC429 Test & Simulation Module CompactPCI-Express/PXI-Express (3U)
ACE429-3U-x
4, 8, 16 and 32 channels ARINC429 Test & Simulation module for CompactPCI-Express/PXI-Express (3U).
-
product
Single Stream STANAG3910 Electrica lTest And Simulation Module – Rafale – for PCI
APXX3910-EN
Single Stream STANAG3910 Test and Simulation Module – Rafale – for PCI with 1 dual redundant HS/LS channel and onboard Electrical Front End. The APXX3910-EN is a functional replacement for model APX3910-EN.
-
product
UV Range Simulators
Textron Systems' operational range systems deliver the same rich, high-fidelity environment enjoyed in systems integration laboratories and on flight lines to training ranges for seamless interoperability and maximized training outcomes. Our modular design allows easy configuration of a multispectral system for training and test to support advanced sensor fusion.
-
product
PXI RTD Simulator Module, 20 Channel, PT1000
40-263-103
The 40-263-103 is a 20-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI RTD Simulator Module 12 Channel PT100
40-262-201
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
product
PXI 6-Channel Battery Simulator Module
41-752-001
The 41-752 is a 6 channel battery simulator, each channel being capable of supplying up to 7V and 300mA to the load. Each channel is fully isolated from ground and from each other allowing the channels to be connected in series to simulate batteries arranged in a stacked architecture. The 750V isolation barrier permits the 41-752 to be used to create a lower power version of a battery stack representative of those used for vehicle propulsion.
-
product
Dual Port Simulator Fiber Channel PCI-X Module
PCI-X FC4 Simulyzer
The modules are available as a single-function board - for analysis or for simulation / data generation - but also as a full-function board for simultaneous analysis and simulation. With a simple firmware/software upgrade, a single function board can become a full function board without having to purchase new hardware.
-
product
PXI Millivolt Thermocouple Simulator Module - 24 Channel
41-760-002
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
Single Stream STANAG3910/EFEX Test & Simulation Module For 3U PXI Express/Compact PCI Express
ACE3910-3U-1
STANAG3910/EFEX Test and Simulation module for CPCIe/PXIe (3U) with 1 Dual Redundant HS/LS channel. Onboard Fibre Optic Front End (FOFE). Easily select between EFAbus and EFEX modes for Tranche II Eurofighter.
-
product
3U cPCI Synchro/Resolver Simulation Board
75DS2
NAI’s 75DS2 is a Synchro/Resolver Simulation Board with four independent, isolated channels. These channels can incorporate up to four Digital-to-Synchro/Resolver Simulation Converters with 1.5, 2.2, or 3 VA drive capability, or either two or four Digital-to-LVDT/RVDT Simulation Converters. One of the outputs on each channel can be grounded without affecting performance.
-
product
Dual Port Simulator Fiber Channel PXIe Module
PXIe-FC4 Simulyzer
The modules are available as a single-function board - for analysis or for simulation / data generation - but also as a full-function board for simultaneous analysis and simulation. By simply upgrading the firmware / software, a single function board can become a full function board without having to purchase new hardware.
-
product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module
43-670-XYZ-AABBCC
The 41/43-670 range is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. Available with up to four banks, each bank is capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
product
Regenerative Grid Simulator
61800 series
Market demand for Distributed Resource (DR) products such as PV inverters and wind energy systems is steadily growing as the world strives for clean renewable energy sources. This demand has created a need for rigorous regulation testing to standards such IEEE 1547 / IEC 61000-3-15 / IEC 62116 ensuring proper and safe operation of on-grid products. It has become critical to manufacturers to conduct these tests to prove compliance and to relieve product liability concerns. Chroma’s new 61800 family of Grid Simulators has been designed to fulfill these test requirements by providing a full 4 quadrant, fully regenerative, grid simulator with advanced features for compliance, safety and product verification testing.
-
product
Thermocouple Simulator Module for SLSC
Bloomy’s 8-Channel Thermocouple Simulator Module provides eight channels of galvanically-isolated thermocouple simulation and simulates types E, J, K, M, N, and T thermocouples. High-precision digital-to-analog converters which are isolated from each other and from system power provide sub-microvolt resolution and accuracy. Built-in switching provides open-circuit faults as well as switching to system calibration resources.
-
product
PXI/PXIe LVDT/RVDT Simulator Module, 4-Banks
41-670-101-AABBCC
The 41/43-670-101 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 16 Channel
41-761-003
The 41-761-003 is a low voltage 16-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 24 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
PXI RTD Simulator Module, 12 Channel, PT500
40-263-302
The 40-263-302 is a 12-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
VXI Synchro/Resolver Simulation & Measurement
65CS4
NAI’s 65CS4 is a Synchro/Resolver Simulation & Measurement Instrument on a single-slot VXI board. The board incorporates up to four Synchro/Resolver measurement channels and up to four instrument-grade Synchro/Resolver simulation channels, or up to eight embedded grade Synchro/Resolver simulation channels that can be used independently and/or simultaneously.
-
product
PXI RTD Simulator Module, 20 Channel, PT500
40-263-102
The 40-263-102 is a 20-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI RTD Simulator Module, 8 Channel, PT500
40-263-402
The 40-263-402 is an 8-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI Battery Simulator Module, 4-Channel, 5 Amp
41-754-011
The 41-754-011 and 43-754-011 are 4 channel battery simulators, capable of supplying up to 8 V and 5 A per channel. The channels are fully isolated from ground and from each other allowing series connection to simulate batteries in a stacked architecture. The isolation barrier (1000 V channel to GND and 750 V channel to channel) allows the module to be used as a battery stack representative of those used for vehicle propulsion..