Pulse Current
-
Product
Split type Pulse Current Sensor
CTF-05
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
High accurate AC pulse current sensor for power demand meter.
-
Product
Split type Pulse Current Sensor
CTF-05M
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Pulse current detection for power demand meter.*Through hole type CT.*Open collector output.
-
Product
Split type Pulse Current Sensor
CTF-05T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
For detecting current pulse with open collector output (for power pulse)
-
Product
Pulse Current Generator Multi-Pulse Generator
-
Shanghai Guantu Technology Co., Ltd.
What is the difference between ordinary current and pulse current?The difference between ordinary current and pulse current: ordinary current is continuous and uninterrupted current.Pulse current is a current whose direction does not change and whose intensity changes periodically with time.
-
Product
Power Sources
MS-Series
-
The MS-Series Power Sources are high performance, high efficiency, AC to AC converters. Rugged powerful output provides up to 350 amps of pulse current for driving non-linear loads.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-1500B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Milliohm Meter
16502
-
Chroma Systems Solutions, Inc.
Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-800B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Split type Pulse Current Sensor
CTF-03
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Suitable for the operation and cable continuity check of the equipment by pulse current detection method. Wide AC current range from 0.1mA to 8A. Ultra compact and light weight. High sensitivity and least affection from external magnetic field.
-
Product
Current Pulsers and Laser Diode Drivers (Pulsed Current)
-
These instruments generate current pulses whose amplitude is largely independent of the load voltage. This makes them ideal for pulsing device whose voltage may vary with time (for instance, the voltage drop of laser diodes may vary with temperature, or explosive squibs which change impedance during ignition). This voltage independence is a trade-off with speed. If faster rise times are required, consider using pulsed voltage instruments instead.
-
Product
Reflectometer
T-510
-
Techno Instrumentation (India) Private Limited
Pulse Echo, Impulse current and Decay methodprovided to get the distance to almost all typesof faults.Laptop based 15 inch display with user friendlyinterface for easy operation.Online support of experts to review fault graphs.Comparison feature of any 5 graphs for reviewand analysis to get more accurate results.Velocity of propogation(VOP) control makes iteasy to precisely pre-locate faults in cables withdifferent velocity.Automatic storage of more than 10,000 faultgraphs.
-
Product
Open Loop Current Sensor
C03 30A
-
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
Product
120 A High Voltage 50 Ω Pulse Generator
TLP-12010C
-
High Power Pulse Instruments GmbH
- High pulse output current up to 120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical rise time 100 ps (0 A to 40 A) and 300 ps in high-current mode (0 A to 120 A)- Wafer, package and system level TLP, VF-TLP and HMM testing- Up to 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 USB programmable pulse rise times: 100 ps to 50 ns (custom selectable)- 8 (optional 9) programmable pulse widths: 0.5 ns (optional), 1 ns to 100 ns (0 A to 40 A), 1 built-in pulse width: 100 ns (>40 A)- The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0 A to 40 A)- Optional external pulse width extensions from 5 ns to 500 ns (>40 A to 120 A)using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient sofware for system control and waveform data management- The sofware can control automatic probers for fast measurements of complete wafers- Combines TLP-12010A and TLP-4010C into one system- Can be operated together with TLP-12012A6 and TLP-3011C pulse width extenders- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface
-
Product
High Voltage 50 Ω Pulse Generator
TLP-4010C
-
High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Ultra fast 50 Ω high voltage pulse output with typical 100 ps rise time*Built-in HMM (IEC 61000-4-2) pulse up to ±10 kV*High pulse output current up to ±40 A*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns*Optional pulse width extender increases pulse width up to 1.6 µs in 68 programmable steps*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurement of complete wafers*High performance and high quality components
-
Product
100 Watt Dynamic Measurement DC Source, 20V, 5A
66332A
DC Power Supply
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections. The Keysight 66332A Dynamic Measurement dc Source provides dynamic measurement and analysis of voltage and current waveforms. It is ideal for testing digital wireless communications products/components because it not only provides the power for testing, but also performs the peak current measurements required to characterize the pulsed current demands of these products.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-200B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
High Voltage 50 Ω Pulse Generator
TLP-8010C
-
High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns (0-40 A), 1 built-in pulse width: 100 ns (> 40 A)*The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0-40 A)*Optional external pulse width extensions from 5 ns to 500 ns (> 40…80 A) using the external pulse width extender TLP-8012A5*Built-in pulse reflection suppression*Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components
-
Product
Power Cable Fault Locator
TM500
-
TM500 Power Cable Fault Locator adopts international advanced electronic testing technologies and SCM technology, and combines low-voltage pulse reflection and pulse current testing methods, is suitable for the precise range finding of power cable high resistance, flashover, disconnection, and low resistance. Low-voltage pulse reflection method applies to test the range of the low resistance and broken line, and the length and wave velocity of various cables. Pulse current testing method can be divided into breakthrough high-voltage flashover and DC high-voltage flashover for the high resistance and flashover cable fault finding.
-
Product
Closed Loop Hall Effect Current Sensors/Transducerswith Rectangle Windows
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used formeasurement of DC and AC current, pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
Product
8 Channel Portable Data Acquisition Logger w/ 5" Touchscreen
Titan S8
-
The Titan S8 portable data acquisition logger combines industrial toughness with scientific accuracy to create a powerful, versatile standalone logger. In any environment, from the laboratory to the factory floor, the Titan S8 simplifies complex validation tasks with its eight input channels and a full-color, user-friendly touchscreen interface. No matter the task, the Titan S8 brings valuable, real-time temperature, pulse, current, and voltage data to users’ fingertips without any need for a PC. The Titan S8 is the ultimate companion for any service, equipment, or compliance engineer. Its handheld portability and shock absorbing boot empower users to bring powerful, instantaneous data acquisition wherever it is needed.
-
Product
SpikeSafe DC / Continuous Pulsed Current Sources
-
The Vektrex SpikeSafe™ DC / Continuous Pulse (DCP) Current Sources provide reliable DC or pulsed drive for LED or laser diode reliability testing, IESNA LM-80 maintenance testing, and other test applications requiring DC or continuous pulse current. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, accurate pulsing over long output cables, precise current, precision pulsing for improved measurement repeatability, and high power density — typically 6.4kW-8kW.
-
Product
High Voltage Snubber Capacitor
STP-01RN / STP-01RB
-
This series of capacitors is Plastic Enclosure, Dry construction design and doesn't have leakage problem when compared with traditional Metal Enclosure Oil impregnated capacitors.Handle high surge current, RMS current and surge voltage with Temperature up to +105CCapacitance : 0.25uF - 60uF ( can be customized )Voltage range : 900Vdc to 5,300Vdc / 280Vrms to 1,600VrmsRMS Current - Irms : up to 80Armspeak to peak pulse current - Ipp : up to 15,000AppTemperature ranges : +85C / +105C
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-1000B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Direct Current Measurement Card
LQI5
-
Computer Gesteuerte Systeme GmbH
The LQI5 is a precision direct current measurement card. It features 6 measurement ranges for unipolar current measurements of up to 32 A. Current pulses shorter than 5 seconds can be measured up to 65 A.
-
Product
IC Side Channel Analysis
-
These probes allow you to couple fast, transient magnetic field, E-field, and current pulses into ICs.
-
Product
Counter And Rate Meters
-
We carry a wide range of counter and rate meters including totalizers, batch controllers, and more. Available with pulse, magnetic or DC pulse, analog, voltage, current, and frequency input types.
-
Product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
Source Measure Unit
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
Pulse Magnetic Field Generator
SKS-0902
-
Shanghai Sanki Electronic Industries Co., Ltd.
The technical parameters of the pulsed magnetic field generator SKS-0902 fully comply with the new standards of IEC61000-4-9 and GB/T17626.9; the pulse current output of up to 2000A can meet the needs of different user groups; it adopts a self-developed CNC high-voltage power supply, High precision, high stability, long service life; using self-developed high-voltage electronic switch as the main switch, high stability, smooth output waveform; achieving 0°~359° synchronous phase triggering.
-
Product
For Detecting Low Range And Leakage AC/DC/Pulsed Current.
FDAZCT-20LSP-0.3S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Lowest Influence from Magnetization,Temperature *Change,Residual Current and Terrestrial Magnetism.*Low Cost and High Performance (Output Linearity ±1% F.S)
-
Product
Primary Cable Fault Locating
Directional Impulse Detector
-
The Directional Impulse Detector ( D.I.D.) is a compact handheld detector used to locate primary cable faults by sensing the magnetic field generated by the current pulse from a high voltage discharge device (thumper). A meter deflection indicates the intensity of the received signal. No deflection indicates that you have walked beyond the fault or away from the cable.