Insertion Loss & Return Loss
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
-
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
40-204-001
-
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
Product
SIM, Module, ITA, 90 Series, Fully Loaded with pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106)
510171102
-
This fully loaded SIM module kit comes with 34 pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106). This kit also includes two PCB brackets for securing module to PCB.
-
Product
Adapter Rails (for High Speed Inserts), i2MX, ITA, 88 Pos, 11 Slot
510144001
-
Allows use of SIM inserts in i2MX ITA. Accommodates 11 single-slot inserts.
-
Product
HFC 7 Ways Return Path Optical Receiver 1 Way Reverse Optical Transmitter
HR2071A, HR2071B
-
Hangzhou Huatai Optic Tech. Co., Ltd.
HR2071 series of HFC seven-way return path receiver, one way reverse optical transmitter, mainly used at the head-end to convert upstream optical signal to RF signal at the user side. Moreover, send back the data at sub-HE to main head-end through one way of DFB return path transmitter. Eight independent units integrated into a 1RU 19" casing to provide service for HFC network terminal of ONTs. The receivers’ low noise design of -22dBm receive sensitivity, allow to supply service to farther distance. There are two versions of this receiver. HR2071A with LCD on the front panel, HR2080B without LCD. All receivers are temperature tolerance type can be installed in any network surroundings including out-door type. Both of these two types can adopt SNMP function, which can control the front panel to realize optimization work at the head-end and remote installment.
-
Product
PXIe-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module
780587-14
-
PXIe, 7-Channel, 40 A PXI Signal Insertion Switch Module—The PXIe‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXIe‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs).
-
Product
Tray Return Systems
-
Rapiscan® Systems range of Tray Return Systems (TRS™) are designed to allow for increased throughput, reduction in staff tray handling and the ability to increase passenger focus amongst various other benefits at security checkpoints.
-
Product
SIM, Module, Receiver, 90 Series, Fully Loaded with pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106)
510170102
-
This fully loaded SIM module kit comes with 34 pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106). This kit also includes two PCB brackets for securing module to PCB.
-
Product
PXIe-2515, 35-Channel, 0.25 A PXI Signal Insertion Switch Module
780587-15
-
PXIe, 35-Channel, 0.25 A PXI Signal Insertion Switch Module—The PXIe‑2515 is a multiplexer switch module that enables connectivity by routing high-speed digital I/O (DIO) signals between a device under test (DUT) and an NI high-speed DIO device or a parametric measurement device. You can use modules such as PXI Source Measure Units (SMUs) and PXI Digital Multimeters (DMMs) with high-speed digital devices. With the PXIe‑2515, you can perform parametric tests on digital pins without external connectivity or impedance mismatch challenges.
-
Product
Return Band Alignment System
6103/6106
-
Enable a single technician to perform return band alignment with this easy to use return band alignment system for CATV. This system consists of a headend signal level receiver/telemetry transmitter (the HECTER 6103) and a small, field portable, dual-carrier signal generator/telemetry receiver unit (HECTER'S PUP 6106).
-
Product
Signal/Mini Power/ Mini Coax, Module Insert, ITA, i2 MX, TriPaddle, 8/8 Position
510144005
-
Signal/Mini Power/ Mini Coax, Module Insert, ITA, i2 MX, TriPaddle, 8/8 Position
-
Product
Tool, Insertion, QuadraPaddle, ITA, Wire Wrap Contact
910113106
-
Tool, Insertion, QuadraPaddle, ITA, Wire Wrap Contact - this tool is used for insertion of QuadraPaddle ITA Wire Wrap Contacts (P/N 610138122).
-
Product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 4 Channel
40-200-004
-
Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signaling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.