Compensators
-
Product
NI-9211, 4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input Module
779001-01
Temperature Input Module
4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input ModuleThe NI‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Digital E-Gun Sweep
XYC-20
-
The XYC-20 E-beam evaporation controller is in a class by itself. The unit can be calibrated by the user to their specific system and e-gun. An algorithm determines the beam error from front to back and side to side within the pocket, eliminating pocket overshoot and burn-thru. The pattern control is effectively made linear saving time in programming and setup. Beam dwell time can vary at each location to compensate for variation in beam density. Six pocket sizes and two shapes can be selected.
-
Product
Single/Multi-Channel Industrial Safety Ozone Monitor
Model 465L
-
Teledyne Advanced Pollution Instrumentation
The Model 465L UV Photometric Ozone Monitor is an extremely stable analyzer, ideal for critical low-level ppm safety and process applications. Its calibration is NIST traceable and the included pressure and temperature compensation ensure high accuracy under all conditions.
-
Product
Infrared Video Processing
-
*Edge Enhancement improves the apparent sharpness of an image by boosting the contrast of edges in the imagery *Electronic Image Stabilization compensates for jitter in a video sequence, providing stabilized video output and remaining responsive to intentional user panning*Auto-Focus automatically adjusts the lens focus to its optimal in-focus position *Electronic Zoom uses interpolation to produce an enlarged image on the video display *Non-Uniformity Correction compensates for detector-to-detector non-uniformity to provide a well-calibrated image output
-
Product
Brix Meter
-
Hand-held, digital brix meterLight-weight, portable, includes protective carrying caseMeasures concentration of sugar and dissolved solids in aqueous solutionAutomatic Temperature Compensation (ATC)Ideal for on-site measurement of juices and other sugar-based liquidsDetermine fruit quality during harvest, shipping, receiving, processing, storage
-
Product
Conductivity/TDS/Salinity/Temperature Pen
Ultrapen™ PT1
-
This portable water analysis instrument is designed to be extremely accurate, fast and simple to use in diverse water quality applications. Advanced features include the ability to select from 3 different solution types that model the characteristics of the most commonly encountered types of water; proprietary temperature compensation and TDS conversion algorithms; highly stable microprocessor-based circuitry; user-intuitive design; and waterproof housing. A true, one-handed instrument, the PT1 is easy to calibrate and easy to use. To take a measurement, you simply press a button then dip the pen in solution. Results display in seconds.
-
Product
Bluetooth® Enabled Free Chlorine Equivalent (FCE ™) & Temperature Pen
UltrapenX2™ PTBT4
-
*Accuracy of up to ±0.3 ppm FCE*Calibration with pH and ORP Standard Solutions*Automatic Temperature Compensation*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Waterproof*Powered by One N Type Battery (Included)
-
Product
Humidity Transducers & Transmitters
-
TE Connectivity (TE) offers packaged humidity and temperature sensors with voltage (analog) output signals. Designed for 2% accuracy in ranges from 10-95% relative humidity (RH), these sensors can be used for HVAC and air quality applications in which compensation for humidity is required. A specialized version for low RH settings is available.
-
Product
Thermocouple Data Logger
IM2000 Series
-
We have been offering IM2000 Series Thermocouple Data Logger with direct interfaces for various types like J / K / R / S / T / B / E etc. Loggers have built in ambient compensation. The thermocouples are most commonly used sensors for measuring temperature in process industries. These can take any form and are available in various mechanical shapes. The temperature ranges are varied.
-
Product
Liquid Flow Meters
L Series
-
Alicat Scientific, Incorporated
Alicat’s L-series liquid flow meters uses our patented laminar flow design to provide users with fast, accurate, and repeatable volumetric flow measurement for water or selected other liquids (see Quick Specs below). At the heart of Alicat’s L-Series liquid flow meters is an internally compensated, laminar differential pressure measurement technology that yields linear results over a wide flow range.
-
Product
Closed Loop Hall Effect Current Sensors/Transducers
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
Product
9 Inputs Satellite Multi-Switch
HJMS-900B (Stand alone)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
*8 satellite IF & 1 terrestrial TV inputs. *Built-in amplification circuit to compensate cable loss.* 13/18V.22KHz and DISEqC. *Suitable for residential multiple LNBs reception. *Sheet Metal Housing.
-
Product
Power Potentiostat/Galvanostat
1100C
-
The Model 1100B series power potentiostat/galvanostat is designed for electrochemical applications that require relatively large current and high compliance voltage, such as battery studies, corrosion, electrolysis, and electroplating. The current range is 2 A, and the compliance voltage is 25 V. The instrument contains a high speed digital function generator, a fast data acquisition system, filters for current signals, iR compensation circuitry, a potentiostat, and a galvanostat (Model 1140B). The potential control range is 10 V.
-
Product
E-Series Average Power Sensor
E9301A
Power Sensor
Measure the average power of all modulation formats Wide dynamic range (-60 dBm to +20 dBm) and frequency range 10 MHz to 6 GHzHigh maximum power specification Low SWR for reducing mismatch uncertainty Calibration factors linearity and temperative compensation data stored in EEPROM Fast measurement speeds (up to 400 readings per second with the Keysight E4416A)Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
Restrained Airspeeds
-
These airspeed indicators have restrained movements.These instruments are actuated by ram air and ambient atmospheric pressure obtained from the aircraft pitot and static pressure systems. A moveable pointer and a fixed dial indicate airspeed with the zero index at the 12 o’clock position. Temperature compensation is internal and there is no external zero adjustment. Pointer damping is internally adjustable.
-
Product
Water Cut Meter
-
The Drexelbrook Universal IV Series products feature full compensation for both temperature and density as well as multiple mounting options which includes insertion and spool piece probes.
-
Product
ORP/Redox & Temperature Pen
Ultrapen™ PT3
-
This instrument is designed to be extremely accurate, fast, and simple to use in diverse water quality applications. Advanced features include highly stable microprocessor-based circuitry; automatic temperature compensation from 15ºC to 30ºC while in calibration mode; user-intuitive design; and waterproof housing. A true one-handed instrument, the PT3 is easy to calibrate and easy to use. To take a measurement, you simply push a button then dip the PT3 in solution. Results display in seconds.
-
Product
Material Sensor
E1737A
Environmental Sensor
The Keysight E1737A Material Sensor monitors the temperature of an object being measured or of the work piece itself. The sensor detects temperature changes and automatically compensates for thermal expansion errors.
-
Product
Trunk Amplifier
-
The trunk amplifier is designed to compensate for attenuation and additional amplification of signals from GPS and GLONASS satellite radio navigation systems as part of synchronization and common time equipment.
-
Product
DC-to-250MHz 1:100 Oscilloscope Probe Kit (HP-9258)
PRB-HP-9258
-
The Oscilloscope Probe 1:100 - HP-9258 is a low-input capacitance high voltage 1:100 oscilloscope probe with a bandwidth of 250 MHz designed and calibrated for use on scopes having an input impedance of 1 MOhm shunted by 20 pF. However, it may be compensated for use with oscilloscopes having an input capacitance of 10 - 35 pF.
-
Product
Dual Temperature
-
The Fieldpiece Dual-Temperature Accessory, model ATH4, measures two temperatures simultaneously using the included k-type, wrap tab beaded thermocouples. The technology inside the ATH4 provides superior temperature compensation in rapidly changing environments commonly found while performing field service. Use the ATH4 to find Delta T and just about any temperature split you want to measure. Displays T1, T2 and T1-T2 on your Fieldpiece meter, handle or data logger. It is included with the HVAC Guide® System Analyzer to get target superheat and for the Target Evaporator Exit Temperature test. Fieldpiece offers a wide variety of k-type thermocouples for various HVAC specific applications. Use pipe clamp T/Cs with the ATH4 to check for blocked filters.
-
Product
Automatic Battery
BATLV480
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations.
-
Product
C Series Temperature Input Module
Module
The C Series Temperature Input Module features up to 16 channels of temperature input from either thermocouples or RTDS. This module can include anti-aliasing filters, open-thermocouple detection, and cold-junction compensation. Additionally, the module also feature isolation for safety, noise immunity, and high common-mode voltage range.The C Series Temperature Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
MAX PH/ORP/ISE/Temp Logging Bench Meter
MW160
-
The Milwaukee MW160 4-in-1 MAX pH/OPR/ISE/Temp. Logging Bench Meter has won fans around the world with its reliable, fast, simple operation as well as a tough, sleek, lightweight design with a small lab space footprint. It is cccurate to ±0.01 pH with automatic or manual temperature compensation, and built in dedicated GLP key. In addition, up to 3-point automatic calibration and 7 selectable buffer standards makes the MW160 MAX ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.
-
Product
Fixed Batteries (Constant Function)
-
Lifasa - International Capacitors, SA
Fixed compensation equipment has different variants depending on the type of enclosure / support and the configuration of the equipment (type of capacitor).
-
Product
Automatic Battery
BATLV360
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations.
-
Product
Sensor Node
Smart Parking
-
Libelium Comunicaciones Distribuidas S.L
The main method is magnetic detection: a 3-axis magnetic sensor reads the variations in the Earth's magnetic field. The big mass of metal of a car parked on the slot changes this field and the node will know. The software inside the node implements advanced algorithms to dynamically compensate the temperature variations and also the influence of neighbor cars.
-
Product
CO2 Concentration
H5524
-
The CO2 measurement is based on a 2-source, 2-beam process. CO2 measurement with long-term stability is guaranteed thanks to the proven non-dispersive infrared (NDIR) CO2 measurement cell. The unique patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field.
-
Product
E-Series Average Power Sensor
E9301B
Power Sensor
Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to +44 dBm10 MHz to 6 GHz frequency coverage for Wireless Comms formats Low SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF800
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation ofpower factor in low voltage instalations