Impedance
-
Product
High Impedance Differential Module
HID
-
Use the HID module in conjunction with a high-speed overcurrent relay to provide three phase high impedance differential protection for substation busbars of any voltage level. Additionally, it can also be used to protect electrical machines like transformers, generators or motors against restricted ground faults.
-
Product
Vector Network Analyzers
-
RF VNA to a Broadband VNA, from a Premium VNA with the highest performance and no compromises to a Value VNA that offers solid performance with suitable measurement speeds for an R&D environment. No matter what your application, Anritsu has your VNA needs covered. Choose with confidence from the pioneers in VNA measurements, introducing the Wiltron 310 Impedance Meter in 1965, and introducing the first broadband VNA, spanning 40 MHz to 65 GHz, in 1999. The first to cover a span from 40 kHz to 125 GHz from a single coaxial connector.
-
Product
Short Circuit Loop Impedance Meter
AMZC-306
-
Voltage measurement up to 750V and up to 250V with resolution 0,1V ; Measurements using Uni-Schuko adapter or test wires 1,2; 5; 10 and 20m ; Loop impedance measurement with resolution 0,01Ω and much more
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Step & Touch & Earth Impedance
-
The kit applyed with STS 5000, STS 4000 or eKAM, allows to perform the following types of test: soil resistivity, ground grid resistance, step and touch tests and overhead lines zero sequence and mutual coupling coefficients
-
Product
Transformer Short Circuit Impedance Tester
JYW6300
-
This instrument is mainly applicable to low voltage load impedance test of 35kV and above power main transformers (single phase or three phases) in ex-works routine tests, overhaul tests, pre-tests, and acceptance tests.
-
Product
Vector Network Analyzer
Bode 100
-
With the multifunctional Bode 100 you get an exact picture of your electronic circuits and components in a frequency range from 1 Hz to 40 MHz. The Bode 100 is not only a state of the art Vector Network Analyzer, it also works as: Frequency Response Analyzer, Impedance Meter, Gain Phase Meter, Sine Wave Generator.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
CellTest Multichannel Potentiostat
-
Simultaneous Electrochemical Impedance Spectroscopy (EIS) tests can be run on multiple cells by connecting Solartron 1455A/1451A series frequency response analyzer (FRA) modules to the 1470E. These FRAs can operate in single sine correlation or multi-sine / Fast Fourier Transform (FFT) analysis mode, providing the ultimate in speed, precision and accuracy. The 1455A FRA provides high performance impedance measurements over the frequency range 10 μHz to 1 MHz, while the 1451A FRA operates from 10 μHz to 100 kHz.
-
Product
Radio Vector Tester
-
Wuhan Sunma Technology Co., Ltd.
Radio & Vector Network Analyzer adopts the advanced digital and RF combination design technology, fundamental wave frequency mixing technology, digital IF processing technology, intelligent power management technology, etc. It comes with features of high precision, small size, light weight, battery power, can measure SWR, Return Loss, Cable Loss, Impedance, DTF, etc, is used to the field test of cable, feeder, and the reflection parameters test of RF components in science and teaching. SunmaFiber provide all kinds of CATV meters, such as Signal Level Meter, QAM Analyzer, Spectrum Analyzer, DVB/DVC/DVT Analyzer and other TV testers.
-
Product
Transducer Simulator
Model 7
-
Impedance: 350 ohms nominal. Output Ranges: Fixed rotary switch. 0 to 3 mv/v in 6 steps of .5 mv/v .
-
Product
IDM+
-
Multi-functional fault recorder including: -- Disturbance fault record (DFR)- Dynamic disturbance recording (DDR) - Phasor measurement unit (PMU C37-118)- Power Quality (PQ Class A)- Travelling wave fault location (TWS to +/-60m) - Impedance fault location- Protocols (61850, Modbus, DNP3) - Sequence of event recording (SOE)- GPS, IRIG and NTP time sync- iQ+ masterstation software.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
N1.2 Calibration Kit
-
N1.2 Calibration Kit, Frequency Range: up to 1.5 GHz, Impedance: 50 Ohm Connector Type: N-type
-
Product
Calibration Kit
N611
-
*N611 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm. * Connector Type: N-type.
-
Product
Return Loss, Impedance & Balance Measurement Accessory
Model SLM620-1
-
For Loss- Frequency Range : 300Hz to 620KHz.- Impedance : 60 to 1000 ohms (40dB maximum).- Accuracy : ±1dB (upto 300KHz) ±2dB (300KHz to 620KHz).For Impedance- Frequency Range : 300Hz to 620KHz.- Impedance : 60 to 3000 ohms.- Accuracy : ±10% (upto 300KHz) ±20% (300KHz to 620KHz).
-
Product
Benchtop LCR Meter
6365
-
Test Frequency 10Hz-200kHz. Output Impedance 100Ω. 7.0" TFT, 800×480 color screen. Basic Accuracy ±0.05%. Using Graphical Analysis by PC Link. Support RS-232、Handler、LAN、USB Host 、Handler、GPIB.
-
Product
Broadband Dielectric Spectroscopy
-
Material Sensing & Instrumentation
Broadband Dielectric Spectroscopy is a powerful tool for investigating a variety of dielectric processes for both electrical and non-electrical applications. Also called Impedance Spectroscopy, the measurement separates molecular process on the basis of response time, providing a unique relaxation frequency along with a signature variation with frequency.
-
Product
Transducer Simulator
Model TS-16
-
Impedance: 350 ohms nominal. Output Ranges: Fixed rotary switch: 0 to 3 mv/v in 15 steps of .2 mv/v
-
Product
Differential Probe
DP-16V
-
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-50MHz*Input Impedance 30MΩ// 1.5PF*x20, x200, x2000 Attenuator*To Ground MAX. Voltage: 8KV CAT III*Output Impedance 50Ω
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
High Impedance Active Probes
18C & 19C
-
High impedance probes, PICOPROBE® MODEL 18C and MODEL 19C, combine the most advanced MOS and bipolar technologies with special, low capacitance packaging techniques to achieve truly remarkable electronic measurement capabilities. While being manufactured each instrument is individually optimized for the best possible performance. The extremely low input capacitance, high input impedance, and almost negligible input leakage current permits the direct probing of even the most sensitive MOS dynamic nodes. At the same time, the full dc capability of this Picoprobe coupled with the high speed capability permits the full characterization of circuits.
-
Product
Controlled impedance test system
CITS900s4
-
CITS900s4 is the seventh generation of Impedance test system from polar, and typically the most popular model for customers who are new to impedance control. CITS900s4 provides both differential and single ended measurement capability along with 4 channels to provide flexible probe connection.
-
Product
Coax, Contact, ITA, 20/26 GHz, 3.5MM, w/ SMA Adapter, 90 Series Modules only
610102134
Contact Adapter (ITA)
Coax, Contact, ITA, 20/26 GHz, 3.5MM, with SMA Adapter (90 Series modules only)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – brassCenter conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination 3.5mm compatibleInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 26 GHzVSWR 1.15 + .01 (f) GHzInsertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications 3.5mm compatibleEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MΩ min.
-
Product
Impedance Analyzer 1MHz-20Hz
IA1000
-
Frequency range20 ~ 1MHzFrequency accuracy0.005%Frequency resolution0.001% in all frequency rangeTest signal level0.05 ~ 2.0 VrmsTest signal resolution0.001 VrmsTest signal output impedance100ΩImpedance Z range; basic accuracy0.0000Ω ~ 99.99
-
Product
Automated Tuners / Impedance Tuners / Load Pull Tuners
-
MT97x, MT98x and XT98x series automated tuners (also known as automated impedance tuners and automated load pull tuners) are precision instruments that are optimized for a broad class of in-fixture and on-wafer applications, and may be used in any automated or manual application requiring the ability to match the impedance of a microwave circuit element or to establish specific impedances at a terminal interface. The tuner design is based on the slide screw concept using the inherently broadband slab-line transmission structure. Each unit has two non-contacting probes deliver high VSWR with superb accuracy and reliability over a wide frequency range. These probes can be fully retracted leaving a low-loss, well-matched transmission line, which is a significant benefit in power related applications where two-port tuners capable of handling large amounts of power are required. As integral components of Maury Device Characterization Solutions, these PC-based tuners are controlled using Maury's family of Device Characterization Software tools, including MT930 IVCAD, MT993 ATS and the DLL-based measurement automation environment. Maury Microwave automed impedance tuners are ideal for load pull, harmonic load pull, active load pull, hybrid active load pull, noise figure, noise parameters and all automated tuner applications.
-
Product
Cable Fault Locator
TX2002
-
Lowest Cost Full Specification Professional Graphical TDR Rugged Palm Top Design 350g (12oz) 5 Measurement Ranges up to 3500m (11,500ft) 50, 75 & 100 ohm Selectable Cable Impedance Built in Tone Generator for Pair Tracing & Identification Suitable for testing all Communications Cables Water & Dust Proof to IP54 Complete with tool-belt holster & test leads
-
Product
Differential Probe
DP-02VF
-
*150MHz High Frequency*MAX. Input Voltage:*±40V DC or 80V p-p or AC 28V rms*Bandwidth: DC-150MHz*Input Impedance 1MΩ // 7.5PF*X2, X20 Attenuator*To Ground MAX. Voltage: 40V*Output Impedance 50Ω