Speaker Impedance
measure of resistance a speaker puts on an amplifier.
See Also: Speaker, Microspeaker, Loudspeaker, SPL
-
Product
Speaker Component Checker
Cab Driver
-
Whirlwind Music Distributors, Inc.
The CAB DRIVER is a test device for checking the operation of the speaker components within enclosures. A pink noise signal source is sent through pushbutton selectors to an assortment of speaker connectors, including Speakon NL8 and NL4, 1/4" TS and banana jacks. Speaker/ Polarity/ Impedance/ Pink Noise Generator
-
Product
Impedance Analyzer, 20 Hz to 10/20/30/50/120 MHz
E4990A
-
The E4990A Impedance Analyzer has a frequency range of 20 Hz to 120 MHz. The E4990A provides an industry best 0.045% (typical) basic accuracy over a wide impedance range, with a 40 V built-in DC bias source. The equivalent circuit analysis function supports seven different multi-parameter models and helps you to simulate your own equivalent parameter values of components.
-
Product
Impedance Analyzer, 1MHz to 500 MHz/1 GHz/3 GHz
E4991B
-
The E4991B Impedance Analyzer has a frequency range of 1 MHz to 3 GHz. The E4991B provides 0.65% basic accuracy over a wide impedance range with a 40 V built-in DC bias source (Option 001). The equivalent circuit analysis function supports seven different multi-parameter models and helps you to simulate your own equivalent parameter values of components.
-
Product
Speakers
-
Selection of ceiling mount, surface mount, and pendant speakers designed to meet a wide variety of needs.
-
Product
High Impedance Transformers
-
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
Product
Audio Impedance Testers
2706 IM
-
Standard Electric Works Co., Ltd
True measurement of speaker systems actual impedance at 1kHz.. Three test ranges (20Ω / 200Ω / 2000Ω) allow testing of home theater and commercial sound systems. Measures transformer impedances. Battery operated. Low battery indication. Data hold function. Timer function for continuous hands free operation. The timer can last about 3-5 minutes when users press. TEST ON/OFF button.
-
Product
Impedance Stabilization Networks
ISN
-
They are required for the measurement of conducted common mode noise on Telecom Cables of Information Technology Equipment (ITE). These measurements are necessary to meet the requirements specified in CISPR 22 and CISPR 32 standards.
-
Product
Battery Impedance Meter
-
Operation is fast and simple. Just press the spring-loaded probes onto the two poles of the battery. After 1.5 seconds, the unit beeps (indicating good contact) and displays the battery voltage and either the number of siemens or milliohms, depending on the knob setting. The display continues to show these numbers after the probes are removed; it resets only when the probes are pressed onto the next battery. The impedance and voltage of any battery between 1.2 and 60 volts can be read. Because of the wide range of voltages, even single low-voltage cells, such as NiMH, can be measured. The manufacturers of some batteries specify impedance in milliohms while other specify in siemens (one divided by the resistance in ohms). This meter will display both types of impedance for any given battery. Accuracy is +/- 2% of the value.
-
Product
Impedance Standards and Calibrators
-
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
Product
Impedance Meter
ZM-100
-
Monacor International GmbH & Co.
Impedance meter for measuring the impedance (Z) of individual loudspeakers and loudspeaker lines.
-
Product
Speaker Test
-
Determines speaker polarity by analyzing a proprietary signal. See our new demo video of this module. Measures woofers, midrange, and tweeter drivers.
-
Product
Step & Touch & Earth Impedance
-
The kit applyed with STS 5000, STS 4000 or eKAM, allows to perform the following types of test: soil resistivity, ground grid resistance, step and touch tests and overhead lines zero sequence and mutual coupling coefficients
-
Product
Antenna Impedance Analyzer
TZ-900 AntennaSmith
-
Analysis Parameters: SWR, Complex Impedance, R+jX, reflection coefficient, Smith Chart. 0.2 - 55 MHz• SWR
-
Product
High Impedance Probes
-
Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.
-
Product
Battery Impedance Tester
-
Weshine Electric Manufacturing Co., Ltd
The DC test method is adopted to simulate the actual use of the battery in a real and objective way, which can effectively eliminate the hidden dangers such as deficiency, deficiency and connection failure between batteries while measuring the internal resistance of the battery.
-
Product
Impedance Spectroscopy
NuVant EZware-EIS Software Package
-
The NuVant EZware-EIS software package activates Electrochemical Impedance Spectroscopy on the EZstat-Pro, Powerstat-05 and -20 potentiostat/galvanostats. EZware-EIS exports the impedance data to a file format to accommodate free third party EIS analysis software. EZware-EIS is a user-friendly interface that allows selection of the proper scanning parameters, collect the impedance spectra, display data in Nyquist and/or Bode plots and export data in the proper data format for use in EIS analysis software.
-
Product
Impedance Analyzer 1MHz-20Hz
IA1000
-
Frequency range20 ~ 1MHzFrequency accuracy0.005%Frequency resolution0.001% in all frequency rangeTest signal level0.05 ~ 2.0 VrmsTest signal resolution0.001 VrmsTest signal output impedance100ΩImpedance Z range; basic accuracy0.0000Ω ~ 99.99
-
Product
Known impedance for use in loudspeaker measurements
Impedance Box
-
An impedance box is necessary for measuring the impedance of a loudspeaker. Listen Inc.’s impedance box contains a 0.25Ω resistance. This value is suitable for most loudspeakers, but may be easily swapped out for a different value by the user if speakers with a particularly high or low impedance are being tested. It is available with either XLR or 1/4″ balanced connectors. Please specify type of connectors when ordering.
-
Product
System for Determination of Materials Impedance in Impedance Tubes
-
System for determination of materials impedance in impedance tubes is used for evaluation of material’s acoustic properties.
-
Product
Impedance Analyzers
-
The E4990A Impedance Analyzer with a frequency range of 20 Hz to 120 MHz provides an industry best 0.045% (typ.) basic accuracy over a wide impedance range, with a 40 V built-in DC bias source.
-
Product
LCR Meters & Impedance Measurement Products
-
Hewlett Packard, Agilent and Keysight have contributed innovations and product excellence in impedance analysis for over half a century. Whether your application is in R&D, production, quality assurance, or incoming inspection, we take pride in contributing to your success. We strive to deliver complete solutions to meet your needs, from impedance analyzers to a wide variety of test accessories. Achieve success with Keysight’s impedance measurement solutions.
-
Product
High Impedance Active Probes
35
-
The Picoprobe Model 35 has been engineered to meet the stringent demands of advanced high frequency circuit designers.
-
Product
Speaker Consulting
-
From 1993 Peter Larsen has worked as an independent consultant for leading loudspeaker factories all over the world. During his career the Ringradiator, a new Racetrack woofer and a 15mm Mobile receiver have been developed among several hundred other transducers. Complete High End enclosure systems and Monitors are among the latest additions.
-
Product
High Impedance Differential Clock Divider
-
Alliance Support Partners, Inc.
he ASP-DCD-00 board is a high impedance input clock divider circuit. It is designed to provide minimum load to a clock source for frequency measurement. It accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms; it divides the input signal frequency from 2 to 256 times depending on shunt jumper selections on J3. The board requires 5VDC 500mA power source to operate. The output is capable of driving 5V TTL logic levels.
-
Product
Manual Tuners / Impedance Tuners
-
Maury manual tuners are based on precision slide screw technology that utilizes broadband slab line transmission structure and passive probes to create impedances for devices. The probes are designed to be very close to onequarter wavelength in the linear dimension at the mid-band of each range. Since each tuner has two probes, this results in improved matching characteristics for each unit. Another key feature of this series of tuners is the inclusion of a LCD position readout of the carriage position on those units operating below 18 GHz. Higher frequency tuners utilize a micrometer carriage drive. The positional repeatability and high matching range of these tuners make them ideally suited for use as a variable impedance source in applications like device characterization. Such measurements depend upon the ability of the tuner to establish impedances out near the edge of the Smith chart and to reproduce the electrical characteristics as a function of mechanical position. The tuners in this series are also easy to use due to the nearly independent electrical results of the mechanical motions. The depth of penetration of the probe into the transmission line determines the magnitude of the reflection, while the position of the probe along the line determines the phase. While there is some interaction, the effects are almost independent of each other. https://www.maurymw.com/images/mw-rf/mst982e35.jpg
-
Product
Impedance Analyzer 10MHz-20Hz
IA1021
-
Feature Specifications: Dual test mode: Analyzer(frequency sweep) and LCR(single frequency).Measurement frequency: 20Hz to 10MHz, 6 digitsFrequency resolution: 0.001% in all frequency rangeFrequency accuracy: 0.01%.DC bias(program): -10V ~ +10V, 0.005V resolution, accuracy 0.5%.Measurement basic accuracy: Impedance +-0.2%, phase: +-0.1°.Display Range: Z: 0.0000Ω-99.999MΩ.
-
Product
LCR Meters And Impedance Measurement Products
-
Complete impedance measurement solutions to meet your needs from LCR to impedance meters, plus test accessories for various R&D and manufacturing applications.
-
Product
Transformer Short Circuit Impedance Tester
JYW6300
-
This instrument is mainly applicable to low voltage load impedance test of 35kV and above power main transformers (single phase or three phases) in ex-works routine tests, overhaul tests, pre-tests, and acceptance tests.
-
Product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
-
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.