Winding Resistance
-
Product
Winding Resistance Meters
-
The NMC 'TDR' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. 'TDR' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. 'TDR' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.
-
Product
Winding Resistance Test
20A DC booster
-
The 20A DC STCS booster allows to perform resistance tests on a PT with a current up to 20 A DC. The option is used together with STS 5000 and STS 4000 and must be connected to STCS module.
-
Product
Winding Resistance Tester
JYR-50C/40C/20C
-
1. With demagnetization function.2. Testing range reach to 20k3. Also apply to testing tranformer with high winding resistance.
-
Product
Transformer Winding Resistance Tester
KRI 9310
-
KRI 9310 adopt Kelvin four-wire testing method, which effectively eliminates the influence of the resistance of the test line on the test results. It can be able to increases the current to 10A by which can test extremely low resistance to 0.01 Ω(such as amorphous alloy, Copper-nickel, nickel-chromium-iron, iron-chromium-aluminum etc). For the tested objects with high resistance value (CT/PT), the instrument can extend the range to 20 kΩ,so the wide resistance test range enables KRI9310 can cover 80% of the power transformer products on the market and switchgear bus-bar cable etc. The power of the tester use the built-in rechargeable lithium battery that can test hundreds of transformers by one time charging.
-
Product
Transformer Winding Resistance Meters
RMO TD Series
-
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
Product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
-
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
Product
Winding Resistance Meter 50Amps, 2 Channels Rack
WR50-12R
-
Raytech Digital Winding Resistance meter WR50-12R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Winding Resistance Tester
JYR20S/10S
-
DC winding resistance testing is regarded as another essential routine screening tool. It indicates problems such as loose, defective or incorrect connections, which cause enough transformer failures each year to be regarded as a failure category of its own.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
-
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
Product
Transformer Winding Resistance Meter
10A
-
*10A DC continuous current in 4 ranges of 0.01A, 0.1A, 1A and 10A.*4 ½ digit display for higher resolution.*Dual channel measurement.*Suitable for operation in energized switchyard conditions.*Specialized protection circuits for suppression of inductive voltage kickback.*SMPS based - lightweight and portable.
-
Product
Winding Resistance Meter
-
* Selectable four resistance ranges.* 4 1/2 digits LED display* High measurement Current (10A)* True four Technique elimanates lead resistance errors Systems* Fully protected against overloads* Proven design* Computer connectivity through RS 232
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Winding Resistance Tester with Demagnetisation Circuit
WRT-10D
-
The WRT-10D is a high performance winding resistance tester designed for power transformer and large motor applications. It is equipped with a bright LCD display, a rugged high quality cable set, a built-in printer, a full QWERTY keypad and a demagnetisation circuit.
-
Product
Winding Resistance Meter 100Amps, 2 Channels
WR100-12R
-
Raytech Digital Winding Resistance meter WR100-12R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Winding Resistance Meter 15Amps, 2 Channels
WR14
-
Raytech's Digital Winding Resistance meter WR14 is the battery powered version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy measurement of very low resistance of any inductive loads.
-
Product
Transformer Heat Run Tester
-
1. Suitable for all transformers below 240MVA heat run test and winding resistance testing.2. Printing heat run data automatically.3. With double power supply, can test high voltage side and low voltage side simultaneously and test any operation respectively.4. With anti breakage protection function of inductive test items.
-
Product
Electrical Measurement Equipment
-
Portable equipment designed for maintenance and commissioning of substations and power plants. Low resistance micro ohmmeters, digital timers, windings resistance, contact resistance, circuit breaker timing and motion, phase angle and frequency measurements.
-
Product
Winding Resistance Meter 50Amps, 3 Channels
WR50-13
-
Raytech Digital Winding Resistance meter WR50-13 is the enhanced version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Fully Automatic Transformer Winding Resistance Tester
-
Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.
-
Product
Transformer Winding Resistance Meters
TWA Advanced Series
-
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
Product
Tap Changer Analyzers & Winding Ohmmeters
-
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints
-
Product
Winding Resistance Meter 100Amps, 3 Channels
WR100-13R
-
Raytech Digital Winding Resistance meter WR100-13R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Primary Current Injection Test Set
T 2000
-
T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.
-
Product
DC Resistance Tester
GDZRS-20A
-
GDZRS series Winding DC resistance tester is optimal designed for measuring three phase winding DC resistance of big capacity transformer. It can test three phase winding DC resistances at the same time
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
Product
Winding Resistance Meter 15Amps, 2 Channels Rack
WR14R
-
Raytech Digital Winding Resistance meter WR14 R is the rack mount version of the WR14. They are designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Current Transformer Analyzer
CT Analyzer
-
Current transformer testing in a multifunctional instrument performing excitation, ratio, polarity and winding resistance tests on current transformers as well as burden impedance measurement.
-
Product
Transformer Winding Resistance Meters
RMO TW Series
-
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
Product
Microohmmeter
MMR-6500
-
The MMR-6500 digital meter is designed for measuring low resistances with a stabilised current of up to 100 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6500 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.
-
Product
Electrical Measurements Test
-
The tests are performed to measure and collect data from electrical and electronic parts using various measurement methods including, but not limited, to the following: capacitance, resistance, winding resistance, insulation resistance, magnetic permeability, power input, and quality factor Q.