Flux
the rate of flow.
-
Product
Industrial Gaussmeter
-
The industrial gaussmeter IGM11 is used to measure magnetic DC and AC fields. The measurands are flux density in Tesla or Gauss and the field strength in Amps per meter.
-
Product
ESD Safe Fume Absorber
-
ESD safe, carbon-activated fume absorber. Flux creates "pine resin", which creates noxious fumes. These fumes cause headaches and nausea. This unit quickly removes these fumes from the work area and filters them safely. Only this newly developed unit, mounted on its versatile 37" arms, allows easy movement to effectively remove these irritating fumes fast.
-
Product
LED Fast-Scan Micro-Spectrophoto Colori meter
8000
-
Shenzhen Chuangxin Instruments Co., Ltd.
The system can determine spectral power distribution, chromaticity coordinates, correlated color temperature, color rending index (Ra), color difference, peak wavelength, spectral half width, dominant wavelength, color purity, luminous flux, test for photometry colorimetry electricity of LED characteristics.
-
Product
Cleaner for Test Probe
EQOmat
-
We have developed EQOmat, a cleaner exclusively for test probes that removes dust such as flux and solder debris adhering to the tip of the test probe. The structure and thinness built with the user's convenience in mind are important items that have sufficient functionality and are indispensable for long-term use of the probe. * EQOmat is an abbreviation for Ecological Qualified Octopus Mat.
-
Product
Measuring Stations
-
The main application is the measurement of the flux density on the surface of multipole magnets or components with magnets. A large amount of measuring stations is built for rotors.
-
Product
Diesel Engine Tachometer
GE-2500
-
The GE-2500 diesel engine tachometer uses rotation speed of an alternator to measure engine rotation speed. With FFT calculation, this tachometer achieves reliable and stable measurement for both diesel and gasoline engines.The OM-1500 is a compact type detector designed for measuring rotation speed of an alternator. It detects magnetic flux leakage from an alternator. It is used to combine with the GE-2500. (The OM-1200 can also be used with the GE-2500.)
-
Product
Underwater Quantum/PAR Sensors
-
Photosynthetic radiation is essential for the growth of the photosynthetic organisms such as corals. The wavelength range from 400 to 700 nm is PAR (Photosynthetically Active Radiation) or PPFD (Photosynthetic Photon Flux Density). Apogee quantum/PAR sensors are calibrated to measure the number of photons of light across this range.
-
Product
N2O/H2O Trace Gas Analyzer
LI-7820
-
The LI-7820 N2O/H2O Trace Gas Analyzer offers high-precision nitrous oxide measurements in a low power, portable design—enabling it to easily integrate into survey and long-term soil flux systems. Pair it with the LI-7810 CH4/CO2/H2O Trace Gas Analyzer or LI-870 CO2/H2O Analyzer for CO2 and CH4 measurements at your site.
-
Product
XRF, AA & ICP sample preparation
Claisse Range
-
Designed for unprecedented analytical accuracy and repeatability, Claisse® electric and gas automatic instruments set new benchmarks in fusion capabilities. The same is true for Claisse pre-fused and homogeneous borate fluxes, high-quality platinumware, as well as analytical consulting services.
-
Product
Hall Effect Measurement system
HMS-3000
-
Hall Effect Measurement System is very useful for measuring Carrier Concentration, Mobility, Resistivity and Hall Coefficient that should be pre-checked in order to grasp the electrical specifications of semiconductor device. Therefore, it is essentially required system to understand the electrical characteristics of semiconductor device.Ecopia’s HMS series consist of constant current source , terminal conversion system by Van der Pauw technique, low temperature(77K) test system and magnetic flux density input system. So, it is well-established system that has all the things needed to Hall Effect Measurement System.
-
Product
Lamp-Based Calibration Light Sources
-
Lamp-based calibration light sources from Gamma Scientific are used for optical calibration of light measurement instruments including spectroradiometers, photometers and radiometers. All of our calibration light sources meet rigid quality standards for use in the most challenging testing environments. A wide range of light sources is available to serve as precision standards of radiant flux and white-light standards of spectral irradiance or luminance.
-
Product
Gaussmeter/Teslameter
Model 2100
-
The Model 2100 Gaussmeter is a fully featured, high-end Gaussmeter with a low cost Gaussmeter price. It is a compact, high accuracy, microprocessor controlled, flux density measuring instrument. The Model 2100 is capable of measuring static (DC), alternating (AC), or pulsed magnetic fields. Twelve measurement ranges allow the operator to configure the meter for maximum resolution and accuracy from 300mG (30 microTesla) to 300 kG (30 Tesla). Selecting primary measurement functions is quick and easy with dedicated front panel function keys. An easy-to-use menu allows access to user defined parameters such as upper and lower magnetic limits and relative magnetic measurements. Remote meter configuration is completely accessible using the built in RS-232 Interface or optional IEEE-488 Interface.
-
Product
GO-NR1000 Near-Field Goniophotometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
Suitable for LED light source, LED chip, module and other small light source, the principal function includes: spatial light intensity distribution curve, spatial color distribution curve, iso-lux curve, total luminous flux, effective luminous flux, spatial luminance curve, etc.The test data can be saved as IESNA (*.ies), CIBSE (*.cib), EULUMDAT (*.ldt), CIE (*.cie), CEN (*.cen) and other formats, which can be directly used as the input data of international general lighting design software. Spatial luminance data can be imported into near-field lighting generation software to generate light data that can be imported into third parties (TracePro and LightTools).
-
Product
Heat flux plate
HFP01
-
Hukseflux Thermal Sensors B.V.
The HFP01 heat flux plate (also called heat flux sensor) offers a solution for measuring heat fluxes. HFP01 is the world's most popular sensor for heat flux measurement in the soil as well as through walls and building envelopes. By using a ceramics-plastic composite body the total thermal resistance is kept small.
-
Product
GO-SPEX500 Goniospectroradiometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
Suitable for all kinds of indoor lamps, flood lamps, road lighting lamps and all kinds of light distribution performance test, total luminous flux, luminaire efficiency and electrical parameters (voltage, current, power, power factor) measurement.Test data can be saved as IESNA(*.ies), CIBSE(*.CIB), EULUMDAT(*.LDT), CIE(*.cie), CEN(*.cEN) and other formats, which can be directly used as the input data of international general lighting design software.
-
Product
Irradiance Probe
LPUVB01
-
The LPUVB01 probe measures irradiance (W/m2) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m2) in the UVB (280 nm …315 nm) spectral range.
-
Product
Long-Term Systems
-
A long-term system from LI-COR lets you accomplish more with your multiplexed soil gas flux measurements. Connect up to 36 chambers to evaluate both spatial and temporal flux variation across a footprint of up to 2800 square meters.
-
Product
PPID-2000 Photosynthetic Photon Intensity Distribution Test Unit
-
Hangzhou Everfine Photo-E-Info Co., LTD
It is mainly used for testing plant lighting products. With the EVERFINE GO-R5000 goniophotometer system, it can realize the measurement of plant photosynthetic photon intensity distribution (μmol/s/sr) in the whole space. In addition, the device can also realize the test of photosynthetic photon flux, far red light photon flux, photosynthetic radiation efficiency and other parameters, referring to DLC, ASABE, DIN, GB, CQC and CSA related international plant lighting standards .
-
Product
CH4/CO2/H2O Trace Gas Analyzer
LI-7810
-
The LI-7810 CH4/CO2/H2O Trace Gas Analyzer offers high performance methane measurements in a durable, portable design. This makes the LI-7810 a great fit for survey or long-term measurements of soil CH4 fluxes.
-
Product
Luxmeter
Digilux 9500
-
Instrument Systems Optische Messtechnik GmbH
The Digilux 9500 of the Optronik line is a high caliber luxmeter for the precise measurement of illuminance, luminousintensity in the lab, or determination of luminous flux with an integrating sphere. It is equipped with a state-of-the-art photocurrent amplifier and microprocessor technology, and offers multiple operating and display functions with an excellent price-performance ratio.
-
Product
Light-resistant Integrating Sphere
-
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
Product
Spherical Underwater Quantum Sensor
LI-193
-
The LI-193 Spherical Quantum Sensor measures PAR in air or underwater from all directions at depths up to 350 meters. This sensor is useful for studies of phytoplankton, which uses radiation from all directions. The measurement is referred to as Photosynthetic Photon Flux Fluence Rate (PPFFR) or Quantum Scalar Irradiance.
-
Product
Spectral Light Meters For Photometric And Colorimetric Measurements
-
Comprehensive range of spectroradiometers for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens), luminous intensity (cd) as well as the colorimetric characteristic values such as chromaticity coordinates (x,y,u',v') or color rendering index (CRI), etc.
-
Product
Fluxmeters
-
Flux meter has been the established standard for the measurement of magnetic flux density for determining total flux in a magnet or magnetic assembly. Its use was curtailed except in a few specialized areas because of many factors such as the difficulty in setting up light beam flux meter or ballistic galvanometers, limitations on the ohmic resistance of search coils, the requirement of some degree of operator skill in reading the flux meter etc. The development of the integrating type Digital Flux meter has virtually cancelled the hitherto negative aspects of fluxmeterology and has found a broad niche for many magnetic measurement applications.
-
Product
Standard Light Source
SLS-50W
-
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
Product
Soil Gas Flux Products
-
LI-COR provides everything you need to get started with your soil gas flux research, including analyzers and hardware to measure, record, and process precise soil gas fluxes with minimal environmental disruption.
-
Product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
Product
Microprocessorized fluxmeter
MSM-101
-
Mobile meter designed to measuring the quasi-static changes of magnetic flux association with induction sensors. The minimal range of meter is equal 0.001Wb/V and drift under 7x10-6Wb/min.
-
Product
Magnet Temperature Characteristics Apparatus
TDF
-
Evaluation of thermal stability of varieties of permanent magnets including rare-earth permanent magnet. TDF-5-200auto This apparatus automatically measures and analyzes reversible temperature coefficient(a) and irreversible temperature coefficient (Flux loss ?f) of magnetic flux density of rare-earth permanent magnet in the wide range from low to high temperature.
-
Product
Hall probes
-
Axial, transverse, multi-axis, and tangential Hall probes for measuring magnetic flux density. Choose from a wide range of lengths and thicknesses—probes are also available for cryogenic applications.





























