Electrodes
-
Product
IDA Electrodes
-
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
Product
Cells and Electrodes
-
Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.
-
Product
pH Electrodes
-
A glass electrode is a type of ion-selective electrode made of a doped glass membrane that is sensitive to a specific ion. The most common application of ion-selective glass electrodes is for the measurement of pH. The pH electrode is an example of a glass electrode that is sensitive to hydrogen ions. Glass electrodes play an important part in the instrumentation for chemical analysis and physico-chemical studies.
-
Product
Electrodes, Sensors And Measurement Cells
-
Our electrodes are used for important tasks in worldwide laboratories with high demands. What began back then with the patent for pH electrodes now includes a range of several hundred different sensors: whether ultra-pure water, jam, wine, creams or drinking water – we offer the right electrode for every conceivable application. Our extensive electrode program is as diverse as the applications.
-
Product
Counter Electrodes
-
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.
-
Product
Electrodes
-
Electrodes are offered in a wide variety of types. Spring electrodes are normally used in the inspection of pipes, although circular brush electrodes can also be used. Flat brush electrodes are used for flat surfaces. Brush materials can be of brass, steel or conductive neoprene construction. Internal electrodes are for testing internal pipe coatings.
-
Product
ESD LCD SURFACE RESISTIVITY METER (WITH 1 PAIR OF 5 POUND ELECTRODES)
-
The ESD LCD SURFACE RESISTIVITY METER provides everything necessary to test work surfaces using the procedure outlined in the EOS/ESD-S4.1 standard. This test kit makes testing surface resistance easy – simply place the weights attach the cables, switch to the correct voltage and press the button to read resistance directly on the meter. The meter incorporates parallel probes on the bottom of the unit which allows the user to make surface resistivity measurements. The parallel probes allow for quick and easy testing of a variety of surfaces and materials, without the use of the five pound electrodes
-
Product
Pin Moisture Meter
-
Pin meters can measure all thicknesses from veneer to logs, flat boards or round and oddly shaped pieces, obtain surface and core measurements. Adding electrodes, pins (up to 7″) optimizes usage. For green, air-dried and kiln-dried lumber.
-
Product
ITO (Indium Tin Oxide) Electrode
-
This quite unique material transmits only visible light whereas it does not transmit UV radiation. Our ITO electrodes consist of 100 nm thick of ITO layer deposited on quartz or borosilicate glass substrate (0.5 mm thick).
-
Product
Multi-Potentiostat
1000C
-
The model 1000B series is a computerized 8 channel potentiostat. The system contains a digital function generator, multiplexed data acquisition circuitry, and a multi-potentiostat that can work with eight independent cells or eight working electrodes in the same solution with common reference and counter electrodes. The potential control range is 10 V for all channels, which can be set at independent potentials or the same potential as the primary channel, so that they can sweep or step potentials together with the primary channel.
-
Product
Decay Accessory Set
PGB-745
-
- Designed for measuring charge movement and decay time of ESD controlled materials- The set consists of two stainless steel electrodes and two very high resistance test leads selected for this application- The high resistance leads minimize leakage during the test cycle and are equipped with male banana plugs
-
Product
Earth Leakage Relay
-
Nippen Electrical Instruments Co.
NIPPEN's Earth Resistance Testers are used for measuring earth electrode resistance, soil resistance, earth continuity, neutral and earth loop resistance, resistance of various components etc.They are used in Railways, Defence, Utilities, Power Plants, Geological Surveys and other Industries.Direct reading type models SET/DET/TET provide direct readings of resistance on moving coil type meters, having a linear scale, 70mm long knife edge pointer and an external zero adjustment.
-
Product
Salinity Meter with Electrode
Salt 6+
-
Automatic Temperature Compensation (ATC) for the optimum accuracy under fluctuating temperatures :: Hold Function momentarily freezes reading for easy viewing and recording
-
Product
Cell Production
-
JRT Photovoltaics GmbH & Co. KG
The production of lithium-ion cell batteries includes the three main process stages of electrode production, cell assembly and formation and aging. Automation is a critical factor for success, particularly in the process stage of cell assembly.
-
Product
Proving Unit & Voltage Tester Kit
DLPK1
-
Touch electrode for Quick testing of fused leads Optical and acoustic continuity Indication Low battery indication A portable, battery powered Proving Unit for testing Two Pole Voltage Testers up to 690V Continuity Tester for testing: Fuses, Fused test leads etc
-
Product
Radiometer Analytical Probes
-
Radiometer Analytical develops and manufactures an extensive range of electrochemical electrodes - combined pH, glass or reference electrodes, metal electrodes, ion-selective electrodes and conductivity cells - for every application and budget.
-
Product
Salinity Testers
-
Labodam pocket salinity testers are equipped with platinum sensors, providing fast and reliable results measuring the salinity of water and other low and high salt concentrated solutions. Equipped with replaceable electrodes, helping to reduce maintenance cost.
-
Product
Portable optical DO meter
ARO-PR
-
The Portable optical DO meter makes use of the fast-response optical DO sensor RINKO, maintaining its high-speed response performance (99% response < 7sec). The meter probe is equipped with a temperature sensor close to the sensing foil, and the measurements are made by simply inserting the probe into a DO sample bottle (the calibration is carried out using the National Metrology Institute of Japan (NMIJ) certified traceable gases standards). Differently from galvanic electrode sensors, the instrument does not require water sample stirring or fixing reagents, since there is no oxygen consumption. Thus, the required time to estimate dissolved oxygen is considerably reduced. The display unit shows the output instantaneously, and you can check the measured values in real time.
-
Product
Micro Volume pH Monitor
UP-100
-
Redevelops HORIBA's founding pH measurement technology using new ultra-small capillary electrode. HORIBA's UP-100 affords ultra-low sample consumption of just 500 uL/measurement, enabling continuous pH monitoring for a variety of critical manufacturing processes that include Semiconductor (Cleaning, Etching and Plating); Chemical Manufacturing, Bio, Pharm, Food Processing, etc.Designed for 6 month continuous operation without operator intervention for minimizing downtime.
-
Product
Bulk Electrolysis Cell
-
This cell has been developed in order to perform a complete electrolysis. The carbon working electrode is a reticulaed form that provides with sufficient surface area to gain the rate in electrolysis.
-
Product
Ion/pH/mV Meter with Single Junction pH Electrode
Ion 6+
-
Direct Ion Concentration for use with most mono- or di-valent Ion Selective Electrodes (ISE) :: mV measurement mode allows you to check performance and calibration of your ISE
-
Product
MyoWare 2.0 Muscle Sensor
-
Using our muscles to control things is the way that most of us are accustomed to doing it. We push buttons, pull levers, move joysticks... but what if we could take the buttons, levers and joysticks out of the equation and control it with our muscles? The MyoWare® 2.0 Muscle Sensor is an Arduino-compatible, all-in-one electromyography (EMG) sensor from Advancer Technologies that allows you to do just that! The MyoWare 2.0 Muscle Sensor has been redesigned from the ground up with a new easy-to-use, compact design and upgraded with the latest and greatest chipset improving sensor performance and reliability. The innovative snap connector system eliminates the need to solder connections for the MyoWare 2.0 ecosystem. It's that easy: stick on a few electrodes (not included), read the output voltage and flex some muscles!
-
Product
pH 700 Benchtop pH Meter
-
The easy-to-use, microprocessor-based pH 700 benchtop meter measures pH, mV, relative mV, and temperature. The large, dual-display LCD provides excellent visibility—even from a distance. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Five-point pH calibration, with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers, makes for easy calibration no matter which requirement you need to meet. Meter features HOLD, ATC, selectable °F or °C measurement, recall of electrode slopand offset, and electrode diagnostics. The convenient pull-out quick reference card keeps procedures handy at all times. Meter accepts any pH or ORP electrodes with a BNC connector.
-
Product
Single Cell Hardware
-
A Fuel Cell Hardware Assembly consists of a pair of Poco Graphite Blocks with a precision, machined flow-pattern (pattern is serpentine unless otherwise specified by the customer), and a pair of gold plated connectors fastened with aluminum end plates. Gas inputs and outputs are through Swagelok fittings. A thermocouple well and two cartridge heaters are also provided. A single Anode Reference Electrode may be added for an additional cost. The FCT Cell Hardware does not include a Membrane Electrode Assembly (MEA).
-
Product
Universal Converter
C8000
-
Multi channel converter for all optek photometric and conductivity sensors and electrochemical pH electrodes. Flexible configuration of sensors, measuring ranges, units and product specific setups make the C8000 converter series a powerful device in process monitoring in both conventional and single-use systems.
-
Product
Portable pH/mV Meter with pH electrode, temperature probe
CyberScan pH 11
-
5-point Push-Button Calibration with Auto-Buffer Recognition for quick calibration with no calibration mistakes
-
Product
Resistivity Imaging & Sounding System
Syscal Junior Switch
-
The Syscal Junior is an all-purpose resistivity imaging and sounding system for environmental applications. The system can be supplied as a standard imaging system capable of recording two measurements simultaneously. The second recording channel significantly improves data acquisition time when the instrument is fitted with internal switching board for 24 (Switch-24) 48 (Switch-48) or 72 (Switch-72) electrodes for Electrical Resistivity Tomography (ERT).
-
Product
Corrosion Analysis
Profometer Corrosion
-
The Profometer Corrosion is the most versatile corrosion analysis solution in the market based on the half-cell method. Proceq’s unique wheel electrodes allow the fastest and most efficient on-site testing. As direct successor to the Canin, it is compatible with existing Canin and most third party electrodes.
-
Product
pHTestr® 10 Waterproof BNC Pocket pH Tester
-
Simply choose the electrode best suited for your application, connect the pHTestr BNC 10, calibrate, and measure. Change electrodes to suit your application without having to purchase another meter. Order electrodes separately. Large display and tactile keypad allow for easy calibration along with USA and NIST auto-buffer recognition. Hold function freezes reading on the display for easy recording. Additional features include Valox® sensor housing, self-diagnostic error messages, a battery-life indicator, and an auto-off function to maximize battery life.
-
Product
3D inversion geophysical software for Resistivity and Induced Polarization Data
RES3DINV
-
This program is designed to invert data collected with a rectangular grid of electrodes. The arrays supported include the pole-pole, pole-dipole, inline dipole-dipole, equatorial dipole-dipole and Wenner-Schlumberger. The RES3DINV program uses the smoothness-constrained least-squares inversion technique to produce a 3D model of the subsurface from the apparent resistivity data alone.





























