Electrodes
-
Product
Dielectric/Conductivity Sensor
VariconTM
-
The Varicon sensor is designed for use in presses, molds, bulk materials or laminates where a thin, flexible dielectric sensor is necessary. The Varicon sensor is thin enough to be implanted within a sample or between the plies of a laminate and may be discarded after use. Patterned on a polyimide substrate, the electrode array is designed to allow a choice of three sensitivities, which are selected by cutting off portions of the array at designated lines.
-
Product
Professional Floor Certification Kit
PFC-252
-
The PFC-252 includes Prostat's PRS-812 Resistance System Set with modified 5 pound conductive rubber electrodes and Prostat’s Cable Spacers for exact measurements. The PRS-812 wide range resistance system can take measurements at 10 and 100 volts with accuracy within ±5%. Also included is the PFK-100 Field Meter Set. The PFK-100 set includes Prostat's unique PFM-711A dual range field meter, CPM-720A charged plate monitor assembly and PCS-730 ±1 kv charging source. With this instrument set you can measure electrostatic fields, analyze ionizer performance and assess the voltage generation of materials, equipment and personnel.
-
Product
Fully Automatic Transformer Oil Test Set
OTS-A series
-
The Motwane Manufacturing Company
OTS-A series is fully automatic microprocessor based transformer oil test set designed with advanced features to measure breakdown voltage of insulation oil accurately. The OTS-A Series preprogrammed with worldwide acceptable standards.The user can define customized standards. The large LCD display with menbrane key pad for easy operation. It is provided with internal memory for 100 data storage & built-in thermal printer for onsite report. The kit is protected by automatic detection of poor input ground.The acrylic oil test vessel provided with adjustable electrode gap setting. The voltage calibrator for on site calibration saves cost & time of user.
-
Product
pHTestr® 50 Waterproof Pocket pH Tester,
-
The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.
-
Product
Corrosion Analysis
Profometer Corrosion
-
The Profometer Corrosion is the most versatile corrosion analysis solution in the market based on the half-cell method. Proceq’s unique wheel electrodes allow the fastest and most efficient on-site testing. As direct successor to the Canin, it is compatible with existing Canin and most third party electrodes.
-
Product
Concentric Ring Set
PRF-911
-
- Measures surface resistance per ANSI/ESD STM11.11- Measures volume resistance per ANSI/ESD STM11.12- Meets the requirements of IEC 61340-2-3- Approximates surface & volume resistivity per ASTM D-257- Incorporates a spring loaded, self-aligning center electrode feature to reduce calibration frequency- Includes an insulated and metal dual test bed- Designed to work with a wide range resistance meter and one 5 lb. electrode- Certificate of calibration traceable to NIST included
-
Product
Cell Production
-
JRT Photovoltaics GmbH & Co. KG
The production of lithium-ion cell batteries includes the three main process stages of electrode production, cell assembly and formation and aging. Automation is a critical factor for success, particularly in the process stage of cell assembly.
-
Product
QuadStat
EA164
-
The QuadStat is a software-controlled four-channel potentiostat. Each channel can be used as a single three-electrode potentiostat. Alternatively two (bipotentiostat), three, or four working electrodes can be used in a single reaction chamber with a common reference and auxiliary electrode. Potential at each working electrode can be independently adjusted between 2.5 V, or by using an external waveform generator to between 10 V. The QuadStat can measure currents from pico- to milliamperes, making it ideal for amperometric biosensor research including use as a multichannel monitor for in vivo nitric oxide or dissolved oxgen sensors.
-
Product
Dielectric Material Test Fixture
16453A
Test Fixture
The 16453A is designed for accurate dielectric constant and loss tangent measurements on the E4991A/4291A/B. It employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. The E4991A/4291A/B measures the capacitance created from the fixure, and option 002 firmware calculates the relative complex permittivity as described in the 16451B. Adjustment to insure parallel electrodes is required when using the 16451B. This adjustment is not required with the 16453A because the fixure has a flexible electrode that adjusts automatically to the material surface.
-
Product
Bridge Decking Testing Equipment
-
The testing process can detect blow holes, inclusions or thin areas in 'sprayed-type' membranes. Because the concrete contains a small amount of water, it is electrically conductive and a DC Pinhole Detector can be used to create a high voltage which is passed over the surface by the use of a brush electrode. An alarm will sound to identify any small defects which can be rectified so that the integrity of the coating can be verified.
-
Product
Double Sheet / Splice Inspection
-
Leuze electronic GmbH + Co. KG
Double-sheet control sensors enable the reliable differentiation between one or more layers of very thin objects made of different materials. This allows, for example, single-layer paper sheets to be reliably pulled in or individual electrodes to be stacked for the production of a battery cell. Different operating principles, based on ultrasonics and capacitive sensors, cover the range of materials for different applications. Sensors for splice inspection detect desired and random splices in paper webs independent of the surface color and material properties.
-
Product
Flame Ionization Detector
-
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
Product
Scanning Droplet Cell
VS-SDC
-
Scanning Droplet System (SDC) uses a compact peristaltic pump to force electrolyte through a small diameter tube and into a specifically designed head. This PTFE-based SDC head is machined to allow electrolyte to flow past an installed Reference Electrode and then to a port at the base of the head.
-
Product
Analog Tank Test Kit
4108
-
The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.
-
Product
Static Decay Timer
PDT-740B
-
Designed to measure the time required for a 1,000 volt charge to dissipate to less than 100, 50 or 10 volts in tenths of a second.Used to evaluate the static decay capabilities of materials, personnel, equipment and other products.Compatible with most portable CPM's and field meters having an analog output of ± 2 (10,000 volts equals 1 volt).Used in conjunction with the PFM-711A Field Meter.Can be used with the PGB-745 Decay Electrodes or PRF-911 Concentric Ring
-
Product
Parallel Plate Dielectric Test Cell
LT-4203A
-
The LT-4203A Parallel Plate Dielectric Test Cell is designed for measuring the AC loss characteristics and permittivity of solid laminates and panels per ASTM Standard D150‑98, and implements the guarded electrode (three terminal) measurement preferred as the referee method.
-
Product
Franklin Tester Model
Model FT2
-
Franklin Tester Model FT-2 is designed as per IS:649 & ASTM:717 Standard to measure insulation resistivity of electrical steel sheet. It requires precision & noise free DC regulated power supply and equally distributed pressure on electrode. Franklin Tester FT-2 regulated power supply provides 0.5000V with 0.1% accuracy over load and no load. Most of national and international standard has specified only 0.5%, means FT-2 is equipped with five time better accuracy than required.
-
Product
Bottom Electrode SMD Test Fixture
16198A
Test Fixture
Designed for impedance evaluations of bottom electrode SMDs and supports 201 (mm) and 402 (mm) sizes
-
Product
Static Generation
Charging Electrodes
-
Fraser Anti-Static Techniques Ltd
Provide a safe, controllable, reliable and cost-effective method of applying static charge for temporary adhesion.
-
Product
Bipotentiostat
700E
-
The Model 700D series are computerized general purpose potentiostat / bipotentiostat / galvanostat instruments. A typical application involves a rotating ring-disk electrode (RRDE), but these systems can also be used for other applications where dual channel measurements are essential, such as dual channel electrochemical detection.
-
Product
Voltammetry Cell
VC-4
-
Capable for measuring of 1 - 3 ml of sample volume using electrodes with 6 mm of the diameter. Furnished holder prevents the vial from spilling.