Electrodes
-
Product
Field-installation Type pH Meter (Four-Wire Transmission)
HP-200
-
HP-200 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
Product
Soil Moisture Sensor
SoilWatch10
-
SoilWatch 10 is a soil moisture sensor which allows measuring relative water content in the soil. Our sensor does not have any exposed electrodes that usually corrode in resistive sensors. Whats more the reads will almost not drift over time or with temperature changes. Our sensor will give the same readings regardless of supply voltage. The sensor is weatherproof. It can be buried in soil for extended periods of time without adverse effects on accuracy or reliability. Designed to work with Arduino.
-
Product
Bottom Electrode SMD Test Fixture
16198A
Test Fixture
Designed for impedance evaluations of bottom electrode SMDs and supports 201 (mm) and 402 (mm) sizes
-
Product
Isolation Tester UIP
-
The devices of the UIP (Union Isolations Prüfer) isolation tester series are used to test the pore-free condition of corrosion protection coatings of pipes, vessels or plant system parts. The battery-powered device generates test voltages between 5 kV and 30 kV, which are applied to the grounded test object via test electrodes. The location of a defect is signalized by a spark-over with an additional audible warning.
-
Product
pHTestr® 10 Waterproof BNC Pocket pH Tester
-
Simply choose the electrode best suited for your application, connect the pHTestr BNC 10, calibrate, and measure. Change electrodes to suit your application without having to purchase another meter. Order electrodes separately. Large display and tactile keypad allow for easy calibration along with USA and NIST auto-buffer recognition. Hold function freezes reading on the display for easy recording. Additional features include Valox® sensor housing, self-diagnostic error messages, a battery-life indicator, and an auto-off function to maximize battery life.
-
Product
Fully Automatic Transformer Oil Test Set
OTS-A series
-
The Motwane Manufacturing Company
OTS-A series is fully automatic microprocessor based transformer oil test set designed with advanced features to measure breakdown voltage of insulation oil accurately. The OTS-A Series preprogrammed with worldwide acceptable standards.The user can define customized standards. The large LCD display with menbrane key pad for easy operation. It is provided with internal memory for 100 data storage & built-in thermal printer for onsite report. The kit is protected by automatic detection of poor input ground.The acrylic oil test vessel provided with adjustable electrode gap setting. The voltage calibrator for on site calibration saves cost & time of user.
-
Product
Meter with Electrode
TDS 6+
-
Automatic or Manual Calibration - for quick, easy calibration; use automatic mode with preset calibration points at most popular values or manually set values in the manual mode for more flexibility
-
Product
Direct Burial Half Cell Reference Electrode
DB-A
-
Model DB-A Copper-Copper/Sulfate Reference Electrode designed for direct burial for long term monitoring of buried or earth contacting structures.
-
Product
Online pH Controller
LD-LOPC-A10
-
Online pH ControllerLD-LOPC-A10features 1 to 3 points pH calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. The automatic electrode slope display helps user decide when to replace the sensor.
-
Product
Corrosion Analysis
Profometer Corrosion
-
The Profometer Corrosion is the most versatile corrosion analysis solution in the market based on the half-cell method. Proceq’s unique wheel electrodes allow the fastest and most efficient on-site testing. As direct successor to the Canin, it is compatible with existing Canin and most third party electrodes.
-
Product
Liquid Test Fixture
16452A
Test Fixture
The 16452A provides accurate dielectric constant and impedance measurements of liquid materials. The 16452A employs the parallel plate method, which sandwiches the liquid material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixure.
-
Product
Induction Style Control Relay
1500
-
A floatless liquid level control system from B/W Controls consists of a relay of the proper type, a holder designed to support one or more electrodes or probes in the liquid container, and the corrosion resistant electrodes themselves.
-
Product
Handheld Water Quality Meters
LAQUA DO220
-
Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation0.01 mg/L or 0.1% DO resolutionCompensates salinity, temperature, and atmospheric pressure Allows up to 2 calibration points using galvanic DO electrode°C & °F temperature readingsWith real-time clock and date/time stamp for GLP complianceAuto log data; built-in memory can store up to 1000 dataAuto stable, auto hold, and real-time measurement modesAuto shut-off (programmable: up to 30 minutes)Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mmPhono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slipPowered by 2 x AA batteriesPackaged with galvanic electrode in carrying case3 years meter warranty
-
Product
Plasma Processing Systems
PlasmaSTAR
-
The PlasmaSTAR® Series of Plasma Processing Systems from Axic, Inc. defines a new concept in barrel plasma processing. The systems are based on a modular design concept. Starting with a universal base unit, multiple electrode modules are available for easy insertion into the base unit. You will find the ease of use, variety of plasma processes, serviceability and attractive pricing unsurpassed by any other plasma.
-
Product
Handheld Water Quality Meters
LAQUA PC220
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Continuity of Insulation Tester (High Voltage Method)
ZGQ-16B
-
Shanghai Dean Electrical Co., Ltd
Executive standard: GB/T4074.5-2008/IEC60851-5;Inspection standard: JB/T4279.13-2008Meet GB/T6109-2008 standard requirementsUsed to test the Insulation continuity (namely the pinhole number of enameled wire sample per unit length) of enameled round wires with nominal conductor diameter ranging from0.05mmto1.60mm;8 level test voltages can be selected by pressing button: 350V, 500V, 750V, 1000V, 1500V, 2000V, 2500V and 3000V;Test length ranging 0~99m;Application of SCM control.Automatically complete test process, display wire testing length and pinhole number;Brushless driving motor, guide pulley and take up pulley are equipotent.The electrode insulation to ground, using high resistance material of non-hygroscopic, no leakage, no tracking, easy to clean, Insulation thickness can ensure long-term 3000V voltage effect.Circuit board is subject to anti-static and moistureproof and long-time aging treatment, has more stable quality and higher durability;
-
Product
PH Meter / Tester, 0pH to 14pH, 0.01, 0.2, 400 ms, 0 °C, 50 °C
72-6783
-
The 72-6783 is a 0 to 14pH Meter with 12.5mm LCD display. Any combination of pH electrode and male BNC connector can be used. pH meter included with battery.
-
Product
Premium Conductive Rubber Electrode
PRS-801-WV
-
- Ideal when qualifying or cerftifying material & installation- Each electrode has a resistance of less than 10 ohms- Flatness is measured and delivered within Prostat's specs- Capped to protect the pad against deformation- In accordance with ANSI/ESD S4.1 amd ANSI/ESD S7.1- NIST traceable ceritificate provided for each premium electrode
-
Product
Long Term Test Kit
-
When long term electro-chemical tests (>1000 hours) are run to monitor the cell degradation at the cathode for example, it is important to avoid any contaminant in the gas flow rate.Inconel 601 flange equipped with alumina housing and alumina tube to feed the gas to the electrode during long term test (>1000 h)Typical poisoning is coming from the chromium contained in the steel tubing. The volatile chromium species (Cr6+) will flow into the cathode (with the air) and thanks to the intake of electrons at the electrode, the chromium ion will transform to chromium oxide and be deposited at the cathode triple point. In such a case, the long term test kit is used. The Inconel 601 flange is equipped with an alumina housing (>96 % Al2O3) and the air (or other gas) is led through an alumina tube. The long term test kit is fully compatible with other functionalities proposed with the Open Flanges™ test Set-Up as the integrated steamer or the small pellet test kit. The long term test kit can be implemented on the fuel, on the air or on both sides.
-
Product
Electrocardiogram Logger Sensor
NUL-218
-
Identical in its use to a regular medical ECG (electrocardiogram), this is a rather simple three lead based logger sensor. It presents a heartbeat graph that allows a thorough examination of the heart's electrical activity from three different angles. Unlike most ECG devices, this unit operates with non-disposable electrodes.
-
Product
Analog Tank Test Kit
4108
-
The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.
-
Product
Digital Surface Resistance Test Kit
PAS-853BRM
-
- Surface Resistance Kit from 0.01 ohm to 9.99x1012 ohms- Nominal Full Range Tolerance Averages <±5%- Fully Automatic Resistance Range, Test Voltage and Electrification Period control- Determines if a surface is Dissipative, Conductive, or Insulative- Measures resistance point-to-point(Rtt) and point-to-ground (Rtg)- Measures resistance of Static Control Floors, ESD Work Surfaces and Packaging Material- Conforms to all ESD Association Standards for Resistive Characterization- Includes 2 each Conductive Rubber Electrodes- Packaged in a hard shell Carrying Case- Certificate of Calibration Traceable to NIST included
-
Product
Digital Tank Test Kit
4109
-
The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `
-
Product
Conductivity Transmitter
DO9766T-R1
-
output of a conductivity electrode with temperature compensation into a 4÷20 mA signal.
-
Product
Electrostatic Precipitator
-
HIGHVOLT Prüftechnik Dresden GmbH
Electrostatic precipitators are used for clean process and exhaust gases, for example, in the cement and building materials industry, in steel mills, in conventional power plants, and in waste incineration plants. The dust particles are discharged electrostatically charged by a spray electrode, deflected by a DC electric field and deposited on the electrode.
-
Product
Cell Production
-
JRT Photovoltaics GmbH & Co. KG
The production of lithium-ion cell batteries includes the three main process stages of electrode production, cell assembly and formation and aging. Automation is a critical factor for success, particularly in the process stage of cell assembly.
-
Product
Pocket Water Quality Meters
LAQUAtwin Ca-11
-
HORIBA's unique compact meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop.
-
Product
Dielectric/Conductivity Sensor
VariconTM
-
The Varicon sensor is designed for use in presses, molds, bulk materials or laminates where a thin, flexible dielectric sensor is necessary. The Varicon sensor is thin enough to be implanted within a sample or between the plies of a laminate and may be discarded after use. Patterned on a polyimide substrate, the electrode array is designed to allow a choice of three sensitivities, which are selected by cutting off portions of the array at designated lines.
-
Product
Voltage Logger Sensor
NUL-201
-
This sensor measures voltages across various resistive, capacitive and inductive components, as well as those of photovoltaic cells, batteries and power supplies. This sensor can also be used to measure electrode potentials and to investigate the charging and discharging of capacitors.
-
Product
Dielectric Material Test Fixture
16453A
Test Fixture
The 16453A is designed for accurate dielectric constant and loss tangent measurements on the E4991A/4291A/B. It employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. The E4991A/4291A/B measures the capacitance created from the fixure, and option 002 firmware calculates the relative complex permittivity as described in the 16451B. Adjustment to insure parallel electrodes is required when using the 16451B. This adjustment is not required with the 16453A because the fixure has a flexible electrode that adjusts automatically to the material surface.





























