Electrodes
-
Product
Bridge Decking Testing Equipment
-
The testing process can detect blow holes, inclusions or thin areas in 'sprayed-type' membranes. Because the concrete contains a small amount of water, it is electrically conductive and a DC Pinhole Detector can be used to create a high voltage which is passed over the surface by the use of a brush electrode. An alarm will sound to identify any small defects which can be rectified so that the integrity of the coating can be verified.
-
Product
Portable Conductivity/TDS Meter with Conductivity electrode
CyberScan CON 11
-
User Customizable Functions for options: Normalization Temperature, Temperature Coefficient, TDS (Total Dissolved Solids) factor, Cell constant and many more
-
Product
Model LP: Lumber & Plaster Moisture Meter
MRC006504
-
Offers the same ad the Model L plus spring-loaded electrode buttons for testing irregular, flat, and curved surfaces. Allows moisture comparisons between kiln decks. Tests 1/4" (6.4mm) to 3/4" (1.9cm) thick wallboard and plasterwork.
-
Product
Potentiostat
EA163
-
This modular potentiostat is perfect for cyclic voltammetry and electroanalytical chemistry, and can use two (working and counter), or three (working, auxiliary and reference) electrodes. It can also operate as a galvanostat, ZRA (zero resistance ammeter), and high impedance voltmeter. It must be used together with any e-corder model.
-
Product
Panel Mounting Conductivity Transmitter
DO9786T-R1
-
output of a conductivity electrode with temperature compensation into a 4÷20 mA signal.
-
Product
Walking Test System Kit
PGA-710
-
The PGA-710 Walking Test System is a complete kit designed to perform the walking test per ANSI/ESD STM97.2 and IEC 61340-4-5. The system consist of several devices designed for portability and to perform several different tests which includes measuring the voltage on a person in combination with floor materials and footwear.The kit includes the PGA-710B Data Logger, the PFM-711B Field Meter, CPM-720B Charge Plate Monitor, the PCS-730B Electrostatic Charger, Hand Held Electrode and the Prostat Autoanalysis Software version 2.0.
-
Product
Universal Converter
C8000
-
Multi channel converter for all optek photometric and conductivity sensors and electrochemical pH electrodes. Flexible configuration of sensors, measuring ranges, units and product specific setups make the C8000 converter series a powerful device in process monitoring in both conventional and single-use systems.
-
Product
Galvanic DO Electrode for DO and BOD Measurements in Laboratories
9521-10D
-
- Ideal for laboratory use- Integrated with built-in temperature sensor- Comes with replaceable 7544 DO Electrode Tip, detachable BOD bottle adapter and stirrer - Use magnetic stir plate during measurement- Waterproof
-
Product
Franklin Tester Model
Model FT2
-
Franklin Tester Model FT-2 is designed as per IS:649 & ASTM:717 Standard to measure insulation resistivity of electrical steel sheet. It requires precision & noise free DC regulated power supply and equally distributed pressure on electrode. Franklin Tester FT-2 regulated power supply provides 0.5000V with 0.1% accuracy over load and no load. Most of national and international standard has specified only 0.5%, means FT-2 is equipped with five time better accuracy than required.
-
Product
pH Electrode Holder
PF12
-
Extension of optek sensor bodies for inline pH measurement in industrial installations of various applications. Commonly available Ø 12mm & 120 mm length pH probes can be used and are positioned at an optimum angle into the process stream.
-
Product
Solid State Relay
5200
-
The B/W 5200 Series solid state relays are offered in two basic types for use in a wide range of low and high sensitivity applications.Both 5200 solid state relays are designed to operate on either 115 or 230 volts AC at 50/60 hertz.Both models incorporate a low voltage sensing circuit.Furhtermore, both solid state relays are capable of performing control functions directly from electrodes suspended in a well or tank, the B/W Unifloat level sensing system, or various pilot devices such as pressure, flow and limit switches, thermostats and push buttons.
-
Product
Parallel Plate Dielectric Test Cell
LT-4203A
-
The LT-4203A Parallel Plate Dielectric Test Cell is designed for measuring the AC loss characteristics and permittivity of solid laminates and panels per ASTM Standard D150‑98, and implements the guarded electrode (three terminal) measurement preferred as the referee method.
-
Product
Scanning Droplet Cell
VS-SDC
-
Scanning Droplet System (SDC) uses a compact peristaltic pump to force electrolyte through a small diameter tube and into a specifically designed head. This PTFE-based SDC head is machined to allow electrolyte to flow past an installed Reference Electrode and then to a port at the base of the head.
-
Product
Plug and Switch Testing
-
Applied to test electrical accessories heating conditions when connected to load current, whether the temperature rise of electrode is compliance with standard requirement or not. And it can effectively detect whether the plug bush is slants thin and whether plug and socket cooperated with all right.
-
Product
Concrete Moisture Meter
7410
-
The electrodes transmit parallel low frequency signals, calibrated to give average moisture content by comparing the change in impedance between damp and acceptably dry concrete.Calibrated ready for use on concreteInstant readings on a clear, easy to read scaleFully portable, battery operated and non-destructive
-
Product
Field-installation Type Simplified Fluoride Ion Concentration Meter(Four-Wire Transmission)
HC-200F
-
HC-200F is connected to a fluoride ion electrode (1009) to detect free fluoride ions in the sample water.(Total fluorine is not detected.) It is suitable for fluoride ion monitoring in effluent from factories, e.g., those of semiconductor FPD and glass manufacturers.
-
Product
Model PS-1
16820-100
-
The Model PS1 under tank probe is designed to be used in conjunction with customer-supplied ¾” National Pipe Thread (NPT) PVC piping and the product has a ¾” (NPT) threaded end that accepts a standard coupling. Any number of pipe pieces can be combined via couplings to provide the required probe insertion length under a tank. The probe can be combined with any standard reference electrode with a ¼ x 20 threaded fitting, including the RE-5, RE-5C and RE-7 portable reference electrodes. Reference electrodes are sold separately. The sealed cable to be fed through a customer-supplied PVC pipe comprises #16 AWG wire with red colored PVC insulation and the wire length can be selected via the radio buttons in the field below.
-
Product
Portable optical DO meter
ARO-PR
-
The Portable optical DO meter makes use of the fast-response optical DO sensor RINKO, maintaining its high-speed response performance (99% response < 7sec). The meter probe is equipped with a temperature sensor close to the sensing foil, and the measurements are made by simply inserting the probe into a DO sample bottle (the calibration is carried out using the National Metrology Institute of Japan (NMIJ) certified traceable gases standards). Differently from galvanic electrode sensors, the instrument does not require water sample stirring or fixing reagents, since there is no oxygen consumption. Thus, the required time to estimate dissolved oxygen is considerably reduced. The display unit shows the output instantaneously, and you can check the measured values in real time.
-
Product
Resistance Welding
-
Resistance welding is a method in which the welding works are heated by resistance heat generated by sandwiching the welding workpieces with welding electrodes, passing current through them, and the metal is welded while pressurizing the works.A resistance welding machine composed of welding power supply, a weld head and an electrode. The welding power supply controls a welding current,the weld head exerts a pressure on the material to weld and the electrode provides welding current and pressurization force to the part under welding. We have been providing various kinds of welding power supplies and welding heads to meet these requirements.
-
Product
Cell Stand
CS-3A
-
The CS-3A Cell Stand is adopted with CHI series Electrochemical Analyzers and other apparatus directly. The cell is enclosed in a Faraday cage to reduce electrical interference. A built-in gas control allows purging a sample. Gas line is provided to purge next sample, while analyzing the present sample separately, thus increasing productivity. Magnetic stirrer allows for controlling the mixing of the sample for experiments requiring mass transport of electrolyte or analyte to the electrode surface. Cell top positioner with detachable cell cap allows easy removal and replacement of the cell vial as well as the electrodes for rinsing, cleaning, and replacement.
-
Product
Potentiostat/Galvinostat Electrochemical Instuments
-
- 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information
-
Product
Biosensor isoPod with USB
EPU352
-
A compact signal conditioner for monitoring low current, two-electrode (anode and cathode) amperometric sensors. By setting the polarization voltage to zero it can also be used as a zero resistance ammeter (ZRA).Electrical isolation ensures that readings are not influenced by nearby current sources such as conductivity, or voltammetric electrodes.
-
Product
MyoWare 2.0 Muscle Sensor
-
Using our muscles to control things is the way that most of us are accustomed to doing it. We push buttons, pull levers, move joysticks... but what if we could take the buttons, levers and joysticks out of the equation and control it with our muscles? The MyoWare® 2.0 Muscle Sensor is an Arduino-compatible, all-in-one electromyography (EMG) sensor from Advancer Technologies that allows you to do just that! The MyoWare 2.0 Muscle Sensor has been redesigned from the ground up with a new easy-to-use, compact design and upgraded with the latest and greatest chipset improving sensor performance and reliability. The innovative snap connector system eliminates the need to solder connections for the MyoWare 2.0 ecosystem. It's that easy: stick on a few electrodes (not included), read the output voltage and flex some muscles!
-
Product
Syscal Pro switch
-
The Syscal Pro is an all-in-one multinode resistivity and induce polarization imaging system for environmental and engineering geophysical studies. The Syscal Pro gathers a 10 channels receiver and a 250W, 2000Vpp internal transmitter which make it the more powerful system of the Syscal range. This system allows to perform up to 10 measurements at a time and its switching board allow to work for 48 (Switch-48) up to 120 (Switch-120) electrodes.
-
Product
Dielectric/Conductivity Sensor
Mini-VariconTM
-
The Mini-Varicon sensor is a thin, flexible dielectric sensor designed for cost-sensitive use with presses, molds, bulk materials or laminates. Patterned on a polyimide substrate, the electrode array is designed to allow a choice of high or low sensitivity, selected by either using the whole sensor or cutting off a portion of the array at a designated line. The Mini-Varicon sensor can be supplied without leads, or with custom-length Teflon-insulated leads attached.
-
Product
Portable ORP Meter
YK-23RP
-
ORP meterElectrode included,Electrode dimensions: Dia 12.5mm height, 120mmBNC connectorMeasuring range -1.999mV to +1.999mVResolution: 1mVResistance: 10MohmDC 9 volts, 1mASize: (H*W*D)mm, (205*68*30)mm
-
Product
CMAS Analyzers and Field Monitors
-
Backed by at least one of the 8 corrosion sensor patents wholly owned by Corr Instruments, our nanoCorr analyzers and field monitors are widely used for online and real-time localized and general corrosion monitoring. These ultra-high precision instruments measure extremely low currents in the pico-ampere levels, which can be translated into a corrosion rate as low as a few nanometers per year, in some applications (PDF). Our analyzers and monitors are based on the patented coupled multielectrode array sensor (CMAS) technology which measures the flow of electrons from corroding electrodes to one or more cathodes.
-
Product
Arc Ingintion Tester
-
The product is designed to carry out Arc Ignition Test as per IS/IEC 60947-1 Clause 8.2.1.1.2 (material used for electrical products). The adjustable current source is 230V AC @ 33A. The load is adjusted to get 32.5A at 0.5 power factor. Included on control unit are Digital Voltmeter, Digital Ammeter, Digital Power Factor Meter and Micro Controller based programmable Sequence Timer with LCD display for display & setting. The arrangement is made to mount the test piece with electrodes as per the specification given in the standard.
-
Product
2D Geophysical Inversion Software for Resistivity and Induced Polarization Data
RES2DINV
-
RES2DINV software is designed to interpolate and interpret field data of electrical geophysical prospecting (2D sounding) of electrical resistivity (conductivity) and induced polarization. The inversion of the resistivity and IP data is conducted by least-square method involving finite-element and finite-difference methods. The software can handle data from any electrode array, including Wenner (a, b, g), dipole-dipole, inline pole-dipole, pole-pole, Wenner-Schlumberger, equatorial pole-dipole and non-conventional arrays. Interpolate data from land, under water, and cross-borehole surveys. Easy data conversion from the most popular geophysical instruments including ABEM Lund, Syskal, AGI, PASI, IRIS, SCITREX, etc.
-
Product
Bipotentiostat
PARSTAT 3000A-DX
-
The PARSTAT 3000A-DX from Princeton Applied Research is both a hardware synchronized bipotentiostat/galvanostat and dual channel potentiostat/galvanostat in one. The compact design, based on the popular PARSTAT 3000A, combines 2 high performance, independent potentiostats in a single chassis. Combine this with a hardware synchronized start and the VersaStudio software platform for a fully functional bipotentiostat that is suitable for a range of applications from mechanistic studies and electrocatalyst evaluation using a rotating ring disk electrode (RRDE) to sensor development.