Electrodes
-
Product
Bonding Tester
PTR1102
-
In wire bonding in semiconductor manufacturing, electrodes are joined using gold wires of several tens of microns. In order to measure the pull (tensile) strength and ball shear (shear) strength of this gold wire, this machine has load detection accuracy and fine positioning accuracy. In addition, for the measurement of high load areas such as die shear strength and solder joint strength, this machine supports measurement in high load areas while maintaining accuracy in low load areas by replacing the sensor part.
-
Product
Plasma Processing Systems
PlasmaSTAR
-
The PlasmaSTAR® Series of Plasma Processing Systems from Axic, Inc. defines a new concept in barrel plasma processing. The systems are based on a modular design concept. Starting with a universal base unit, multiple electrode modules are available for easy insertion into the base unit. You will find the ease of use, variety of plasma processes, serviceability and attractive pricing unsurpassed by any other plasma.
-
Product
Electrical Tomography Software
Res2dinv
-
This very popular software, developped by M.H.Loke, uses the method involving the Sasaki minimum squares inversion (1992) to produce a 2D sub-soil model starting from the data of apparent resistivity (up to 2000 electrodes). It is completely automatic and does not require that the user formulates a starting model. When using a state-of-art computer, the inversion of a single pseudosection will require only a few minutes.RES2DINV supports spreading types like Wenner, Schlumberger, Pole-Pole, Pole-Dipole, line Dipole, equatorial Dipole and other non-conventional spreading types.
-
Product
Meter with Electrode
TDS 6+
-
Automatic or Manual Calibration - for quick, easy calibration; use automatic mode with preset calibration points at most popular values or manually set values in the manual mode for more flexibility
-
Product
Digital Tank Test Kit
4109
-
The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `
-
Product
Earth Leakage Relay
-
Nippen Electrical Instruments Co.
NIPPEN's Earth Resistance Testers are used for measuring earth electrode resistance, soil resistance, earth continuity, neutral and earth loop resistance, resistance of various components etc.They are used in Railways, Defence, Utilities, Power Plants, Geological Surveys and other Industries.Direct reading type models SET/DET/TET provide direct readings of resistance on moving coil type meters, having a linear scale, 70mm long knife edge pointer and an external zero adjustment.
-
Product
Cells and Electrodes
-
Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.
-
Product
Nexis GC-2030 BIDUFRGA
UFRGA Series
-
The Ultrafast RGA system utilizes the new Barrier Discharge Ionization Detector (BID) technology coupled with Nexis GC-2030 to create new system GC for ultrafast, high-sensitivity analysis. Since the electrode creating Helium plasma is totally isolated from the carrier gas, there is no chance to contaminate this electrode with a dirty sample. This enables long-term stability.
-
Product
Software to Simulate Large Area Semiconductor Devices
Laoss
-
Laoss is a powerful software to simulate large area semiconductor devices (OLED, thin-film PV), taking into account the voltage drop in the electrodes due to important resistive effects when the size of the device increases.Simulation of large area semiconductor devices (OLED, thin-film PV)Coupling law input: analytical or tabulated (experimental or simulated) IV curveDevice optimization (electrode material, device geometry etc...)High speed computation
-
Product
Fixture and Software for Open/Leak Inspection
-
In addition to jigs and fixtures for probing conductors and electrode pads, NIDEC-READ provides specialized software for test point selection and log analysis.
-
Product
Online pH Controller
LD-LOPC-A10
-
Online pH ControllerLD-LOPC-A10features 1 to 3 points pH calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. The automatic electrode slope display helps user decide when to replace the sensor.
-
Product
Telurometer
AMRU-200 GPS
-
*The only meter on the market that implements all measurement methods:*Technical method of 2, 3 or 4 poles*Drive method (4/10μs, 8/20μs, 10/350μs).*Double-clamp method without the need for auxiliary electrodes.*Soil resistivity.
-
Product
Dielectric Loss Tangent Testing Instruments
-
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
Product
Potentiostats and Galvanostats
-
Potentiostats are feedback amplifiers which control an electrode to a certain potential with respect to a reference electrode. They may control microelectrodes in animal or herbal cells, and the current is measured in picoamperes, or large-area electrodes in batteries or production cells.
-
Product
Geophysics
ELETOM
-
ELETOM is a software that performs complete 2D inversion (and not the simple iterative deconvolution of the pseudo-sections) of surface electrical surveys with any measurement array (Wenner, dipole-dipole, pole-dipole, pole-pole, user defined arrays, mixed arrays) with a maximum of 64 electrode positions that can be added by the user as required.
-
Product
pH 450 Waterproof Portable Meter
-
Backlit, rugged waterproof meter is ideal for any environment!*Intuitive, user-friendly icons — electrode status displays pH slope*Grip-Clip™ electrode holder quickly and easily secures electrode to side of beaker or container*USB or RS-232 output for up to 500 data sets*Extended battery life or optional universal power adapter*Built-in stand with wall mount option allows for easy benchtop measurement or storage
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission, 4 point ararm, Time sharing Proportional Control)
HP-960FTP
-
HP-960FTP industrial pH meter is a high-end pH meter with a four-point alarm and a time sharing proportional control function.It connects pH sensor and measures pH and temperature in the sample water.It can also be linked with a cleaning device via an external input, extending its automatic operation time.Many types of electrodes are available to match the sample properties.
-
Product
Arc Ingintion Tester
-
The product is designed to carry out Arc Ignition Test as per IS/IEC 60947-1 Clause 8.2.1.1.2 (material used for electrical products). The adjustable current source is 230V AC @ 33A. The load is adjusted to get 32.5A at 0.5 power factor. Included on control unit are Digital Voltmeter, Digital Ammeter, Digital Power Factor Meter and Micro Controller based programmable Sequence Timer with LCD display for display & setting. The arrangement is made to mount the test piece with electrodes as per the specification given in the standard.
-
Product
Handheld Water Quality Meters
LAQUA PC210
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Ion/pH/mV Meter with Single Junction pH Electrode
Ion 6+
-
Direct Ion Concentration for use with most mono- or di-valent Ion Selective Electrodes (ISE) :: mV measurement mode allows you to check performance and calibration of your ISE
-
Product
High Speed Spectroscopy Camera
SynapsePlus CCD
-
Superfast electronics (up to thousands of spectra per second). Very low read noise. Best linearity in its class. Different chip types to suit every spectroscopy need. Open Electrode (OE) 1024 x 256 pixels, Front-illuminated UV enhanced (FIUV) - 2048 x 512 pixels, Front-illuminated visible (FIVS) - 2048 x 512 pixels, Back-illuminated UV enhanced (BIUV) - 1024 x 256 and 2048 x 512 pixels, Back-illuminated visible (BIVS) - 1024 x 256 and 2048 x 512 pixels, Back-illuminated deep depletion (BIDD) – 1024 x 256 pixels.
-
Product
Waterproof Meter with 3m Cable 4-Cell Electrode
CyberScan COND 610
-
Measure from pure water to seawater with one meter! COND610 features a broad conductivity range of up to 500mS with auto-ranging capabilities for more convenience.
-
Product
TTC-1 Tracking Test Chamber
TTC-1
-
It is according to IEC60695 and IEC60112 (GB4207), the Tracking Test Chamber TTC-1 is intended for determining the degree of protection against formation of conducting paths in solid insulating materials, due to the electric stress and electrolytic contamination of the surface. This method simulates tracking currents on insulation material by providing drops between electrodes. During the process of normal use, insulating material may be exposed to moisture and dirt, if conductive, may cause stress and fire hazard.
-
Product
Meter w/ pH Electrode, Conductivity/ATC Probe, Integral Electrode Holder
PC 700
-
The multi-parameter Eutech PC 700 measures pH, ORP, conductivity and temperature with a single meter. User-friendly with advanced features and a large custom-size display – perfect for research work on a budget!
-
Product
Earth / Ground Tester
-
Earth testing covers the testing of earth electrodes and the measurement of soil resistivity. The instrument requirements depend on the range of applications.Ground resistance testing covers the testing of earth electrodes and the measurement of soil resistivity. The instrument requirements depend on the range of applications.
-
Product
Plug and Switch Testing
-
Applied to test electrical accessories heating conditions when connected to load current, whether the temperature rise of electrode is compliance with standard requirement or not. And it can effectively detect whether the plug bush is slants thin and whether plug and socket cooperated with all right.
-
Product
Low TCR High Power Current Sensing Resistors, Wide Terminal Type
-
Panasonic Industrial Devices Sales Company of America
Panasonic's ERJ-D1 and ERJ-D2 Series, Low TCR High Power Current Sensing Chip Resistors, achieve high power and low TCR (±100×10–6/°C) using a wide terminal electrode structure and original materials.These Resistors are suitable for small size/high power current detection and their low TCR enables high accuracy of current detection. The ERJ-D1 Series features higher rated power at 2W in a 1020 case size while the ERJ-D2 Series features 1W in a 0612 case size. These Resistors are AEC-Q200 Compliant and offer IEC 60115-8, JIS C 5201-8 and EIAJ RC-2134B Reference Standards ensuring optimal quality and reliability.
-
Product
Micro Volume pH Monitor
UP-100
-
Redevelops HORIBA's founding pH measurement technology using new ultra-small capillary electrode. HORIBA's UP-100 affords ultra-low sample consumption of just 500 uL/measurement, enabling continuous pH monitoring for a variety of critical manufacturing processes that include Semiconductor (Cleaning, Etching and Plating); Chemical Manufacturing, Bio, Pharm, Food Processing, etc.Designed for 6 month continuous operation without operator intervention for minimizing downtime.
-
Product
Potentiostat
EA163
-
This modular potentiostat is perfect for cyclic voltammetry and electroanalytical chemistry, and can use two (working and counter), or three (working, auxiliary and reference) electrodes. It can also operate as a galvanostat, ZRA (zero resistance ammeter), and high impedance voltmeter. It must be used together with any e-corder model.
-
Product
Cross Flow Cell
-
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.





























