Earth
See Also: Ocean, Atmosphere, Ground
-
Product
sbRIO-9265, Non-Enclosed, 4-Channel C Series Current Output Module
780921-01
Current Input Module
Non-Enclosed, 4-Channel C Series Current Output Module - The sbRIO‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The sbRIO‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.
-
Product
Flame Photometers
-
Flame Photometer applies the emission spectrum as the basic principle, which uses the flame heat and excites part of the atoms in alkaline earth metal. The atoms receive energy and transfer it to the old energy level. When the atom is at a normal energy level it releases the energy.
-
Product
NI-9205, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle
865683-01
-
NI-9205, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9205, cDAQ-9171, and cRIO-9940 includes the NI-9205 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9205 features a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Additionally, the NI-9205 provides up to 60 V of overvoltage protection between input channels and common, and it is rated for 1,000 Vrms transient overvoltage protection.
-
Product
System Grounding & Earthing Analysis
-
ETAP's system grounding & earthing foundation automatically detects the system earthing configuration based on source and transformer grounding or earthing type selection. The resulting earthing types are displayed both on the one line diagram and for the various connected cables.
-
Product
High Voltage DC Personal Tester
DC/PT 75
-
Within a matter of seconds you can measure for yourself whether a voltage exceeding 750V is present. Used on voltages up to 75kV DC to earth.
-
Product
Multifunction Installation Testers
-
Shanghai Beha Electronics Co., Ltd.
Loop impedance and prospective short circuit current measurement• Line impedance and prospective short circuit current measurement• Earth loop resistance in TT-systems• Rotary field test• RCD measurements (contact voltage, trip time, trip current - ramp method)• RCD analysis for test of all RCD parameters • Low Ohm and continuity measurement • Insulation measurement up to 1000V (suitable for 690 V industrial mains systems)• Earth resistance measurement with probes and clamp adapters• Voltage and frequency measurement • Current measurement with clamp adapters(optional)• Power and energy measurements• Harmonics measurement for voltage and current upto the 21st harmonics
-
Product
NI-9375, 30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module
781030-02
Digital Module
30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module - The NI‑9375 is a digital I/O interface that works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and other devices. Each digital input line is compatible with 24 V logic levels, and all the output lines are compatible with 6 V to 30 V signals, based on the external power supply. The NI‑9375 offers isolation between the input and output banks from channel‑to‑earth ground.
-
Product
Multifunction Electrical Installations Meter
MPI-525
-
Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.
-
Product
Space Applications & High Performance Cable Assemblies
-
Teledyne Stom Microwave’s space flight heritage began in the 1990s when one of our military/aerospace customers independently performed space qualification testing on our cables. Since 2010, TSM has dedicated design, engineering, test, qualification and documentation resources to specifically service a growing list of military and commercial space customers. These customers include most of the major US defense contractors and a growing number of Low Earth Orbit and small satellite companies.
-
Product
Battery Boxes Testing Equipment
-
Battery boxes can be tested for faults by placing the box on a metal plate. By applying a test voltage to an electrode inside the box, the moulding can be checked thoroughly - particularly at the injection points - and any faults found. Defects will be identified by a spark passing from the electrode, through the defect itself, to earth (the conductive material placed outside the battery box.
-
Product
Installation Testers
-
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.
-
Product
CapaConnect repair defective capacitive string parts
CC-LRP3/4+KS+DS
-
Hachmann Innovative Elektronik
With modules of CapaConnect series you can repair defective capacitive string parts of older installations, or retrofit string parts, where until now only direct cable taps are available. The connections to coupling dielectrics and earth can be carried out without an expensive dismantling normally, as the module contains all necessary components, like surge arresters, plug-in positions for adjustment capacities and high-quality contacts.
-
Product
DC Earth Fault Locator
GFL-T + GFL-R
-
The DC Earth Fault locator is suitable to test the DC Battery System and Trace Ground Faults. The system is suitable for Power Plants, Sub-Stations upto 765KV and other industries. The system is highly capable in tracing and pin pointing the DC earth faults in a live system without requiring any shut downs. The receiver sensitivity of 1mA and better is capable to trace most complex fault.
-
Product
Self-testing Static Grounding Clamp
Bond-Rite CLAMP
-
In many branches of the process industries, fires and explosions can result from electrostatic discharge in hazardous areas. Even relatively small sparks have sufficient energy to ignite many flammable vapours, gases and even airborne dusts. In situations, where this risk exists, static grounding (earthing) and bonding clamps are required wherever mobile or portable conductive plant items (such as drums and vessels etc) are used.
-
Product
Ground-Fault Products for Solidly Grounded Systems
-
Ground-fault products are used to monitor grounded systems (ungrounded and grounded) for fault currents or residual currents. The sum of all conductors except the protective earth conductor is measured by means of measuring current transformers.In general, ground-fault monitors (RCM - residual current monitors) are used to send a message to the user even before reaching the shutdown threshold of the GFCI. Ground-fault monitors detect deteriorations of the insulation level at an early stage and in a reliable way.
-
Product
Fixed GEO Earth Stations
-
Kratos Defense & Security Solutions, Inc.
Kratos provides a broad range of fixed earth stations ranging from 3.5m to 18m and configured in receive-transmit or receive-only mode. These antennas offer outstanding electrical performance and exceptional versatility to support low PIM at certain Ku bands and all X-band systems.
-
Product
Digital Earth Resistance Tester
-
Wuhan Fanke Transformer Manufacture Co., LTD
Digital Earth Resistance Tester
-
Product
NI-9421, 24 V, 8-Channel (Sinking Input), 100 µs C Series Digital Module
NI-9421 / 779002-01
Digital Module
24 V, 8-Channel (Sinking Input), 100 µs C Series Digital Module - The NI‑9421 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with 24 V logic levels and has an LED indicating the state of that channel. The NI‑9421 offers isolation between the input channels and earth ground.
-
Product
NI-9425, 24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module
785044-01
Digital Module
24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module - The NI‑9425 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each digital input line is compatible with 24 V logic levels. The NI‑9425 offers isolation between the input and output banks from channel to earth ground. You cannot use the NI‑9425 in a CompactDAQ chassis to perform counter operations.
-
Product
Run-Time Error Analyzer
Astrée
-
AbsInt Angewandte Informatik GmbH
Astre analyzes structured C programs with complex memory usages, but without recursion or dynamic memory allocation. This targets embedded applications as found in earth transportation, nuclear energy, medical instrumentation, aeronautics and space flight, in particular synchronous control/command such as electric flight control.
-
Product
180V-260V AC Socket Tester With RCD Test (For UK)
1943
-
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 180~260VAC circuit.*LED indicators & Digital display.*30mA leakage current measurement.*RCD Test.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 11W*Frequency: 50Hz
-
Product
Measuring Display Unit Breakers
-
Mitsubishi Electric Automation, Inc
Measuring display units (MDU) are integrated with molded-case circuit breakers and earth leakage circuit breakers for measuring, displaying, and transmitting information on cable ways. This display unit closely monitors energy consumption by measuring current, voltage, power, electric energy, harmonic current, leakage current and power factor.
-
Product
Single channel Motor Insulation Monitor
-
The SURETECH Motor Insulation Monitor measures insulation resistance to earth of electric motors when themotor stops. Motors running from mains (380 / 220V) and higher voltages up to 6.6kV can have their insulationcontinuously monitored.
-
Product
Earthing Resistance Tester
JYD-10A
-
transformer neutral grounding resistor is the vital need in medium voltage AC distribution network that are also called by different names like Neutral Earthling Resistors. They are taken into use to limit the current that would flow through the neutral point of a transformer or generator in the event of an earth fault. They are also used for resistance grounding of connected generators and transformers.
-
Product
Current Clamps and Sensors
-
Are designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. It is specially designed to detect low fault currentson power circuits.
-
Product
Socket Tester c/w Buzzer
DL1092
-
Clear visual and audible indication RCD test of 30 mA RCD (max time 300 ms) Touch voltage to check for extraneous voltage on earth Compact, durable design in compliance with BS EN 61010
-
Product
NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module
779357-01
Voltage Input Module
±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.
-
Product
3D Helmet Coil
-
With the 3D Helmholtz coil system, 3-dimensional magnetic field vectors can be generated. By superimposition, it is possible to create a field-free space or an artificial earth magnetic field vector inside the coil arrangement. The coil arrangement was developed for the calibration of magnetic field sensors.
-
Product
Multifunction Earth Tester
MT-100
-
Multifunction earth tester for measuring earth resistance, continuity of protective conductors’, with touch-screen display and integrated Wi-Fi





























