Immunity
See Also: Immunity Test, Radiated Immunity, EMC
-
Product
Immunity
RF coupling
-
is used for the conducted measurement of the immunity according to IEC 62132-4.
-
Product
Immunity
ESD coupling
-
is used for conducted coupling of Langer ESD pulses (200ps rise time) into ICs.
-
Product
Electromagnetic Immunity Scanner
SmartScan 350
-
Reproducing similar soft or hard failure to the gun test - Flexible automatic failure detection module - Susceptibility map generation- Automatic report generation- Flexible scan area editor (SAE)- Flexible display (3D, histogram)- Matlab support- Expandability (EMI scan, phase measurement, NFFF transformation)- Custom design probes
-
Product
Conducted Immunity Test System
-
Conducted RF immunity tests acc. to IEC/EN61000-4-6 and BCI tests acc. to ISO 11452-4 and MIL-STD 461 CS 114 Signal generator,RF-power amplifier, RF-power meter and directional coupler (optional) in one 19”-caseStand-alone operation possible with optional available netbookControl-software includedMost important parameters are shown on an integrated displayAutomatic EUT-monitoringOperation via USB port of a PC or NotebookComplete range of CDNs available
-
Product
Transient Immunity Tester
KES7700
-
Transient Immunity Tester KES7700 Series are transient surge tester that utilizes a compact unit system. A surge generator circuit is installed for each pulse unit as the tester meets the requirement of ISO7637-2, ISO7637-3, ISO16750-2, JASO D001, SAEJ1113, and other standards. The KES7700 Series meets a broad range of independent automobile manufacturer standards as well.
-
Product
Immunity Development System
-
Used for EMI suppression in printed circuit boards during the development phase. The developer can use the E1 set to quickly identify the causes of burst and ESD interference. This allows the developer to design suitable measures to solve the causes of the interference. It can also be used to test the effectiveness of the measures taken.
-
Product
Coupling Decoupling Network for Conducted Common Mode Immunity Testing According to IEC 61000-4-6
CDN
-
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.
-
Product
Impulse Magnetic Field Immunity Tester
IMF61000-9
-
IMF61000-9 impulse magnetic field immunity tester is high performance test instrument which special designed for to do impulse magnetic field immunity test and fully meet IEC61000-4-9, EN61000-4-9 and GB/T17626.9 standards, also it come with high intelligent, high stable performance and easy operation characteristics.
-
Product
Multifunctional Immunity Test System For Automotive Electronics
EMS-ISO7637
-
EMS-ISO7637 automotive multifunctional immunity test system meet newest ISO7637-2 requirement of
. This standard was issued by international organization for standardization, and this system included all of ISO-7637 required test waveform and meet most of automotive manufacturer’s requirement for automotive electronic immunity test. -
Product
Fibre Network Providers for High Speed and Low Latency Network Infrastructure
-
PBE Group is a fibre network provider that delivers a vast array of integrated tunnelling and mining projects globally and offers custom fiber-based solutions that are reliable, robust and easy to use.Rebroadcasting systems (LTE, FM, TETRA, P25, etc), video monitoring and real time machine control systems can demand high bandwidth and low latency for operation. PBE offers a wide range of fiber-based solutions that can satisfy these requirements. PBE provides Ethernet over Fiber Network and RF over Fiber Network systems in mines and tunnels.Fiber network has a number of advantages:- Covers greater distances with less loss- Support high bandwidth- Immunity to EMI and RF Interference- Support different topologies (Star, Ring, Tree, etc.)- Flexible design and deployment- Flat frequency response and wide frequency ranges- Easy to implement redundant network
-
Product
Dipole Antennas
-
Provides reliable, repeatable measurements. Suitable of FCC, MIL-STD, VDE, Tempest and Immunity stesting.
-
Product
ESD Protection
-
Protection against electrostatic discharges (ESD) is part of EMC Immunity (Electro Magnetic Compatibility) requirements. It is the ability for equipment to properly operate in its electromagnetic environment by limiting the reception of electromagnetic energy that may cause physical damage. ESD can be either conducted under the form of a transient voltage or can be radiated due to its fast rising time: powerful harmonics will generate erratic behavior by the application by coupling with other signals. Printed circuit boards must be protected against the effects of electrostatic discharge.
-
Product
CDN - Coupling / Decoupling Networks
-
The Coupling- / Decoupling Networks are used to inject common mode disturbances to Equipment under Test (EuT). Further the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.
-
Product
EMC Measurements
-
Immunity and emission measurements Kiwa Dare is an accredited test house that performs full compliant EMC measurements in the field of EMC legislation. All results are recorded and represented in reports which form the foundation on which clients can put the CE mark on their product. Besides that our tests are performed under accreditation for Automotive, medical, maritime, aerospace military and railway applications.
-
Product
EOS Tester
KT-200SG
-
This test instrument stands for the EMI(Electro Magnetic Immunity) ability test to the electric devices, electronic circuit boards & electric equipments. Recently this instrument is widly used in many companies in Korea & other countries to test the immunity to thier products-power supply, drive PCBs, communication systems, LCD display panels whether they are safe or not against the impulse & noise.All for the purpose, of this object, it generates 4 ~ 5 kinds of different impulse test waveforms.Output test voltage level : 5 ~ 200 V ImpulseOutput voltage polarity : Positive, NegativeType of waveforms
-
Product
RF swept immunity package
EMiSweep
-
This is a flexible Windows immunity package which provides the utilmate flexible Graphical User interface. Other visual aids provides a swept as well as spot frequency assessment.
-
Product
Semiconductor Products
-
International Testware Corporation
International Testware supports all major ATE models for today's semiconductor products.CredenceAdvantestCaesarHewlett-PackardLTXIMSSchlumbergerAndo...and MANY moreTeradyneMosaidOur Solutions offer:Mixed-SignalEMI ReductionR/FCustom TailoredLow NoiseReliable PerformancePrecise Length MatchingSuperior Impedance ControlCrosstalk "Immunity"Minimal Inductance
-
Product
20W to 30W - Single Output / Multiple Output
PXE Series
-
*Industry Standard 2" x 1.6" Footprint*9-18, 9-36, 18-36, 18-75, 36-75 Vdc Inputs*3.3, 5, 12, 15, ±5, ±12, ±15 Vdc Outputs*1600 Vdc Isolation*-40 to 100 °C Case Temperature*Six-sided Shielding*EN61000-4 Immunity
-
Product
IEC61000-4-4 4.8KV Electrical Fast Transient Immunity Generator
EFT-404BX
-
Shenzhen Chuangxin Instruments Co., Ltd.
EFT-404BX Impulse Generator is fully met requirements of the standards IEC61000-4-4 and GB/T17616.4.
-
Product
Conducted Immunity Test Systems
-
Conducted Immunity System (CIS) to Test According to IEC 61000-4-6. The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes an ACS series power amplifier, coupling/decoupling Network (CDN), directional coupler, 150Ω to 50Ω adapters, power attenuators, cables and [optional] CSAT software. These systems, when properly configured, are capable of testing your products to all levels given in IEC 61000-4-6 up to 230 MHz. You can choose from three systems. Follow the links below for detailed information, including a comprehensive datasheet listing system specs.
-
Product
10W to 60W - Single Output / Multiple Output
PXD Series
-
*Industry Standard 2" x 1" Footprint*9-18, 9-36, 18-36, 18-75, 36-75 Vdc Inputs*3.3, 5, 12, 15, 24, 48, ±5, ±12, ±15, ±24 Vdc Outputs*1600 Vdc Isolation*-40 to 105 °C Case Temperature*Six-sided Shielding*EN61000-4 Immunity
-
Product
15W to 60W - Single Output / Multiple Output
DPX Series
-
*Single, Dual and Triple Outputs*9.5-36 Vdc, 18-75 Vdc Inputs*Meets EN55022 Class B*1600 Vdc Isolation*-40 up to 95 °C Operating Temperature*EN61000-4 Immunity*Narrow 24.5 mm width
-
Product
EMC Testing Knowledge & Equipment
-
Creating, delivering, installing, and training on EMC test systems; RF Immunity systems, RF Radiated and Conducted Emissions systems, Conducted Immunity and Pre-compliant EMC systems.
-
Product
Pre-Scan Emissions/Immunity Chambers
-
3m pre-scan Immunity/Emissions semi-anechoic chambers are designed to perform ANSI C63.4/CISPR 16-1-4 and IEC 61000-4-3 compliant radiated immunity and emissions measurements. When using this chamber for ANSI C63.4 pre-compliant radiated emissions pre-scan measurements there’s a limited scan height.
-
Product
Bulk Current Monitoring Probe
MP-50
-
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Product
Damped Oscillatory Magnetic Field Immunity Tester
DOMF61000-10
-
DOMF61000-10 damped oscillatory magnetic field immunity test system included damped oscillating wave generator and single ring coil, it’s designed for to do damping oscillation magnetic field immunity test and fully meet IEC 61000-4-10, EN61000-4-10 and GB/T 17626.10 standards requirement.
-
Product
40W to 60W - Single Output / Multiple Output
PXF Series
-
*Industry Standard 2" x 2" Footprint*9-18, 9-36, 18-36, 18-75 Vdc Inputs*Single, Dual and Triple Outputs*1600 Vdc Isolation*-40 to 100 °C Case Temperature*Six-sided Shielding*EN61000-4 Immunity
-
Product
15W - Single Output / Multiple Output
PXB Series
-
*Industry Standard 1" x 1" Footprint*9-18, 9-36, 18-36, 18-75, 36-75 Vdc Inputs*3.3, 5, 12, 15, ±5, ±12, ±15 Vdc Outputs*1600 Vdc Isolation*-40 to 100 °C Case Temperature*Six-sided Shielding*EN61000-4 Immunity
-
Product
EFT Immunity Measurement
EFT61000-4
-
EFT immunity tester EFT61000-4 is specially designed according to the characteristics and requirements of EFT measurement and it is an ideal disturbance source of EMS measurement. They have fine performance, such as high stability, high reliability, easy to use etc. It meets the standard requirements of IEC 61000-4-4, EN 61000-4-4, GB/T17215.301, GB/T17215.322 and GB/T17626.4. EFT61000-4 has LCD display in both English and Chinese.
-
Product
TDK Software
-
TDK Software - Testlab, Emissions Lab, Cundicted Immunity Lab, Radiated Immunity Lab, EUT Monitoring Lab, GTEM Emissions Lab