Correlators
-
Product
High Accuracy Spectrophotocolorimeter
LMS-3000
-
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
Product
Dynamic Calibration for ROSS Streak Cameras
DynaCal
-
The DynaCal Optical Calibration Module (OCM) is designed exclusively for the Sydor ROSS Streak Camera to ensure accuracy, both over time and in situ, so you can be confident that the data from your shot is certified to be correlated to the calibration of your camera. The beauty of in situ calibration is that the cost of removing and resetting the camera is avoided—and so is the risk of the replacement of the camera and shifting or disturbing the sensitive nature of streak camera results. Only in situ calibration will reveal the real world effects of EMR, gravity, electronic noise and more when they distort your camera results.
-
Product
Spectrometer & Colorimeter
-
Spectroradiometer is widely used to measure the spectral, photometric and colorimetric parameters of all kinds of lighting sources which usually include relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature(CCT), color rendering index(CRI), dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, luminous flux, Illuminance, luminance, spectral transmittance and reflectance, etc. PIMACS provides different types of spectroradiometers and colorimeter to meet the requirements in laboratories or on production lines. They are applied in the measurement for general light sources, LED & OLED products, displays, etc.
-
Product
STEREO PERFORMANCE METER
SPM-1
-
The SPM-1 measures the stereo content present in any left and right audio program material. It measures 0-50 dB separation on live program material by cross correlating the right and left base-band audio information.
-
Product
Standard Test Systems
WaveCore™ Products
Test System
Textron Systems’ WaveCore family offers a variety of standard test systems with a primary application of satellite payload lab testing. Our systems can be deployed affordably for both production and engineering applications, providing industry-leading levels of data correlation with high system mean time between failures and low mean time to repair.
-
Product
TEM Lamella Preparation And Volume Imaging Under Cryogenic Conditions
ZEISS Correlative Cryo Workflow
-
ZEISS Correlative Cryo Workflow connects widefield, laser scanning, and focused ion beam scanning electron microscopy in a seamless and easy-to-use procedure. The solution provides hardware and software optimized for the needs of correlative cryogenic workflows, from localization of fluorescent macromolecules to high-contrast volume imaging and on-grid lamella thinning for cryo electron tomography.
-
Product
Turbidity Meter
TF16-N
-
The TF16-N is a high precision turbidity meter for installation into pipelines measuring scattered and unscattered light at two independent angles in various liquid process streams. The ratio of scattered to un-scattered light can then be correlated.
-
Product
Emissions Reference Source (ERS)
Emissions
-
The ERS is a comb generator that radiates RF continuously every 2MHz over the range 30MHz - 1000MHz. Each 2MHz peak is precisely measured during the calibration process with the ERS orientated both vertically and horizontally. These measurements are correlated against a 3m OATS such that any fully implemented CISPR16 site, measuring at 3m and using height scanning, will read the same.
-
Product
Signal Analysis
Synchronous Accumulation (Order Analysis)
-
Order analysis is one of the most convenient and efficient methods for diagnostics and balancing of rotating mechanisms and transmission gears. With an RPM sensor and a vibration sensor, it is possible to study the time characteristics of gear vibration signals. It is a well-known fact that a signal from a vibration sensor is affected by signals from other sources. To tune out from the disturbing signals, the synchronous signal accumulation method is used. For each shaft rotation, the RPM sensor provides a rotation mark. This signal serves as a triggering strobe for the vibration sensor signal sweeping. The obtained signal sweeps are combined. All the sources of the signals related to the shaft frequency (frequency of rotation) are accumulated and increased in the accumulator linearly proportionally to the N number of rotations. All other signals that are not correlated with the shaft frequency are accumulated proportionally to N1/2 and in case of a greater number of averagings, the useful signal exceeds the interference level.
-
Product
Logger version chlorophyll and turbidity sensor with wiper
INFINITY-CLW ACLW2-USB
-
Infinity-CLW is an autonomously deployable data logger for long-term chlorophyll and turbidity measurements. The light sources (LEDs) of chlorophyll and turbidity sensors are highly stable, Minimizing the change over time. The instrument has a mechanical wiper that periodically sweeps to inhibit biological growth on the optical window. The turbidity sensor has a good correlation with SS (Suspended Solid) over the range. Infinity-CLW provides Highly accurate and long-term stable chlorophyll and turbidity data in oceans, rivers and freshwater.
-
Product
Modulation Distortion Up To 8.5 GHz
S930700B
-
S930700B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 8.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930700B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
Innovative Software Tool Solutions
-
IoT brings networking to a wide range of potential "things" ranging from everyday devices to sensors and actuators. Telchemy's management architecture is uniquely designed to handle massive numbers of devices, providing data correlation, reporting and action triggers.
-
Product
Ultra-Low Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300U
-
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
TCSPC Lifetime Kit
DeltaTime
-
The DeltaTime time correlated single photon counting (TCSPC) lifetime plug-in offers acquisition speed, flexibility, and affordability unavailable in any other multifunctioanl fluorescence solution on the market. DeltaTime seamlessly integrates monochromators, polarizers, and other accessories with the widest array of sources (LEDs, laser diodes, supercontinuum lasers) and detectors (including NIR), providing lifetime coverage from 25ps to 1sec over wavelengths spanning the UV to NIR.
-
Product
Digital Image Correlation (DIC) Measurement System
EduDIC
-
EduDIC is a complete Digital Image Correlation (DIC) measurement system, designed as a simple and convenient educational training tool for academic courses in experimental solid mechanics. This easy-to-use system allows academic instructors to effectively present the optical measurement technique of DIC for materials testing to the engineers and scientists of tomorrow.
-
Product
PXI-6229, 32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module
779115-01
Multifunction I/O
32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXI‑6229 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Carbon Monoxide Analyzer(CO)
AQMS-400
-
FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology.
-
Product
Collaborative Correlative Microscopy
nanoGPS navYX
-
Correlative microscopy is the combination of multiple modalities performed on the same sample. The results produced emphasize the strengths of each modality while offsetting their individual limitations.nanoGPS navYX™ is an open solution which makes SEM-Raman correlative microscopy seamless regardless of the electron and optical microscopes used. Simply stick the Coordinates Transfer System to the sample!
-
Product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
-
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.
-
Product
Carbon Compounds Analyzers
-
TML's Carbon compound analyzers utilize Gas Filter Correlation combined with reliable NDIR (non-dispersed infrared) technology to produce very stable and accurate gas measurements. All T Series analyzers offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our analyzers are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
Product
PXI-6225, 80 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO, PXI Hybrid, Multifunction I/O Module
779296-01
Multifunction I/O
80 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module - The PXI‑6225 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Dual Port Simulator Fiber Channel XMC Module
XMC-FC4 Simulyzer
Simulator
*Two independent fiber channel ports*The two SFPs accept electrical as well as optical transceivers*Each port supports 1, 2, or 4 Gbps*Supports customer-specific defined transmission speed*Comprehensive decoding of FC-1, FC-2 and Upper Layer Protocol (ULP) frames*Triggering and filtering*Supports DMA for high-speed streaming*IRIG-B time code encoder / decoder for data correlation*Supports ULPs such as FC-AE-ASM, FC-AE-RDMA, FC-AE-1553 and FC-AV*Supports HS-1760E applications such as AS5653, AS5652 and AS5627*Optional fcXplorer, Windows-based FC simulation and analysis test software*FC SDK (Software Development Kit) provides drivers and APIs for Windows XP / 7,*Linux, VxWorks, QNX Neutrino RTOS and others on request
-
Product
Custom Bench Test
-
TestEdge provides customized bench test. If your device has specialized test requirements, it may be necessary to test your device using specialized bench equipment rather than traditional ATE. In other situations, both ATE and a custom bench setup may be required to fully characterize the device and provide necessary correlation. Finally, it may be useful to create a custom bench setup to facilitate device debug.
-
Product
Phase Noise Analyzer
NXA-26
-
This new NXA-26 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 26.5 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range. The NXA-26 combines over 25 years of Phase Noise Measurement Technology with an easy to navigate user interface. System operation requires minimal training that will have you making measurements in minutes.
-
Product
Nanomechanical Instruments For SEM/TEM
-
As the world leader in nanomechanical testing systems, Bruker makes it easy for you to conduct in-situ mechanical experiments in your microscope with the Hysitron PI Series PicoIndenters. Our unique transducer design delivers unmatched stability throughout your experiments, resulting in precise data even at the nanoscale. Video capture from the microscope enables real-time monitoring and direct correlation of mechanical data to microscope imaging. With solutions designed to fit many of the microscope brands in use, you are sure to find one that is ideally suited to your research.
-
Product
Signal Analysis
Cross-Correlation Analysis
-
The software is used for correlation analysis of signals coming from the input channels of FFT spectrum analyzers in real time or recorded time realization view mode, as well as for viewing various correlation characteristics of signals. Correlation analysis is a set of methods based on the mathematical correlation theory and is used for detecting the correlation dependence between two random attributes or factors. For solving a number of diagnostic tasks, cross-correlation analysis of signals in two or more control points distributed across space is often used.
-
Product
FLIM Upgrade Kits for LSMs
-
As technology leader in equipment and techniques for single photon counting, Becker & Hickl offers a wide range of high-grade Fluorescence Lifetime Imaging (FLIM) systems for laser scanning microscopes since 1998. Our techniques have found broad application within the scope of Life Sciences, Clinical FLIM, Diffuse Optical Tomography (DOT), Fluorescence Correlation (FCS, FCCS), Förster Resonance Energy Transfer (FRET) and more.
-
Product
Phase Noise Analyzer
NXA-50
-
This new NXA-50 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 50 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
Product
VIS/NIR Sensor
AF26
-
The AF26 is a high precision dual channel color sensor for inline operation; the secondary wavelength is designed to compensate the desired light absorbance measurement from any undesired light scattering influence, such as suspended solids, gas bubbles, immiscible fluids or window fouling. The AF26 sensor’s output can be correlated to almost any color scale including APHA and Hazen.
-
Product
Radiometer Spectral sensitivities precisely adapted to the measurement task
UVS-B-T
-
Compared to the spectral response of the UVS-E, the UVS-B-T has a sharper cut-off at the transition from UV-B to UV-A. This feature reduces the UV-A contribution to the radiometer output and permits the highest possible correlation to atmospheric UV-B irradiance.





























