Voltage Loggers
Record voltage measurements.
See Also: Loggers, Pressure Loggers, Current Loggers, Dataloggers, Humidity Loggers, Temperature Humidity Loggers, Temperature Loggers, Wireless Data Loggers, Wireless Loggers, Data Loggers
-
Product
Voltage USB data logger
EL-USB-3
-
This data logger measures and stores up to 32,510 voltage readings over a 0-30V d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista.
-
Product
sbRIO-9215, Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Modul
780878-01
Voltage Input Module
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9215 performs differential analog input. The sbRIO‑9215 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
AC-Powered, AC Voltage Monitor, Adjustable
VMA
Voltage Monitor
NAI’s VMA is a field-adjustable, AC-Powered, AC Voltage Monitor used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits.High and low voltage limits, and "pick-up" and "drop-out" time delay are field-adjustable. The VMA voltage monitor is ideally suited for rugged defense and industrial applications.
-
Product
sbRIO-9229 , Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
780874-01
Voltage Input Module
Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9229 performs differential analog input. The sbRIO‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Non-enclosed modules are designed for OEM applications.
-
Product
sbRIO-9201, Non-Enclosed, ±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
781113-01
Voltage Input Module
Non-Enclosed, ±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The sbRIO‑9201 is an effective combination of channel count and speed at a low price for an economical multifunction system. In addition to the absolute protection from the isolation, the module features up to 100 V of overvoltage protection for errant signal connection or unexpected outputs to the individual channels. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779014-01
Voltage Input Module
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
Product
Process Voltage & Current Data Loggers
-
Monitor and log virtually any process voltage or current output from your transducers.
-
Product
NI-9264, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
780927-02
Voltage Output Module
25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The NI‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the NI‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection.
-
Product
sbRIO-9221, Non-Enclosed, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
781116-01
Voltage Input Module
Non-Enclosed, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The sbRIO‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the sbRIO‑9221: a 36‑position spring‑terminal connector and a 37‑position DSUB connector. Non-enclosed modules are designed for OEM applications.
-
Product
Data Loggers
-
Identify trends in vibration, noise, temperature, humidity and more that can be indicative of component wear and/or influence machine performance with help from PCE Instruments' data loggers.
-
Product
Voltage Data Logger
VA601-V1
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multi-function record meter is a new record meter designed for the actual demand of various industrial site, which integr.
-
Product
Data Logger
ADlog
-
With ADlog, you use ADwin-Pro, ADwin-Gold and ADwin-light-16 flexibly for recording, visualizing and evaluation of large data amounts without programming effort.
-
Product
Data Logger
MS6R
-
The complete solution for monitoring of temperature, humidity and other values. For desktop use with rubber feet - see Optional accessories. For mounting to 19" rack - one rack unit 1U.
-
Product
Data Logger
DL6
-
Monitor and troubleshoot HVAC systems, verify energy management systems, or track performance of pneumatically controlled valves with Series DL6 Pressure/Temperature/RH Data Logger.
-
Product
Data Loggers
-
Digital Readout Meter• 5-Decade, Auto Ranging• Stores 1000 Data Points• Supports GM, Proportional & Scintillator Detectors• Ratemeter/Scaler Modes• Supports 16 Detector Setups• DTC & Adjustable Window• RS-232 Port
-
Product
Data Loggers
-
Scientech Technologies Pvt. Ltd.
Onset data loggers and weather stations are used in a broad range of indoor, outdoor and underwater applications.
-
Product
Cyclops Logger Software
-
The Land Cyclops Logger Software allows you to connect a Land Cyclops Portable pyrometer to a personal computer or mobile device and view, analyse and record live temperature readings.
-
Product
Midi Logger
GLT400
-
*Transferring data to PLC via Modbus/TCP protocol*DC Power only for -20 to +60 operation*Supports WEB server, FTP server and FTP client network functions for remote monitoring and controlling*High Isolation inputs to ensure signals are not corrupted by noise from other channels*Connect as a remote terminal unit of GL840
-
Product
Data Loggers
-
Omega's data loggers offer dependable performance in all types of environments. Choose based on measurement type or form factor to meet your size and data logging requirements.
-
Product
Multichannel Data Loggers
-
Check Your Solar Power Levels and Verify Integrity to Solve Power Loss Problems
-
Product
Data Loggers
-
Data loggers are small electronic devices used to track and store location-specific data via built-in or external sensors. They are typically battery-powered and equipped with internal memory, and have become the predominant method of monitoring in most contemporary industries, having increasingly replaced the electromagnetic chart recorders that originated back in the early 19th
-
Product
Flameproof Data Loggers
-
Our clients can avail from us Flameproof Data Loggers that are ideal to measure parameters, such as temperature, voltage and flow. These are required and used for applications where recording is not important.
-
Product
Temperature Logger Sensor
NUL-203
-
This is one of our most versatile sensors. It can be used in biology to monitor ecological systems, microbiological cultures and to study the effect of temperature on photosynthesis and enzymatic reactions. In chemistry, to study exothermic or endothermic reactions and how the rate of reaction is affected by temperature; in physics it can be used to study heat/energy transfer.
-
Product
Battery Data Logger
BDL-3927
-
Kongter Test & Measurement Co., Limited
BDL-3927 is updated Battery Data Logger to meet IEEE measurement standards for battery voltage, string voltage, current and ambient temperature. It is customized from 12V to 700V for different battery systems. And it has easy expansion for all battery systems. With wifi communication, you could easily view complete data and generate test report in the PC software.
-
Product
Data Loggers
-
Data loggers are the core component of NRG’s complete system approach to wind and solar measurement applications. Data are collected from readings of meteorological sensors and other devices and then stored in our loggers for either manual retrieval or automated delivery to the location of your choice.
-
Product
Isolated AC Voltage Input Module
ADAM-3112
Voltage Input Module
0 ~ 450 VAC to 0 ~ 5 VDCAC voltage measurement1,000 VDC isolation between output and power2,500 VAC isolation between output and inputInput impendent: 2 MohmMulti input modesAccuracy: ±0.1% FSRFlexible Din-rail mountingOperates from a single +24VDC
-
Product
uSD Logger Shield
IFB-11001
-
This micro SD logger shield enables time-stamped logging of any signals measured by your Arduino project! Whether sensor shields, breakout boards or datalink connections, this shield will get your logger project up and running quickly. We've included an MCP79410 Real-Time-Clock module for flexible supply voltage timekeeping, which includes an on-board battery holder for a CR1220 battery (included, and is installed). In addition, the micro SD card is interfaced through a high-speed translator IC and supplied with a high-current LDO to meet the demands of the SD standard. Each pin of the Arduino has an offset pin attached for easy wiring to the massive 13x9 pin prototyping area, including the pins connected to the ICSP header! Whether you're using a Mega, Due or Uno, this board has your interfacing needs covered! Finally, the micro SD holder is a push to lock, push to unlock type, which makes it really easy to both install and uninstall your card.
-
Product
NI-9260, 51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module
783466-01
Voltage Output Module
51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module - The NI‑9260 is an instrument-grade dynamic signal generator for testing the audio components and capabilities of consumer electronic devices and providing excitation in structural test applications. Unlike sound card-based solutions, the NI‑9260 can be deployed quickly and recalibrated to guarantee long-term measurement repeatability and decreased test time. It also features ±30 V overvoltage protection and short circuit protection.





























