Wavelength
See Also: Wavelength Meters
-
Product
PIN + TIA Optical Receivers
-
Discovery Semiconductors, Inc.
Linear and High Gain VersionsDifferential or Single-Ended RF OutputsLowest PDL (typical 0.05 dB)Useable Spectral Wavelength Range of 1064-1650 nm
-
Product
Fixed Spot Non-Contact Thermometers / Pyrometers
-
SPOT is a family of fully featured, high performance pyrometers for fixed non-contact infrared spot temperature measurements. Available in range of operating wavelengths, temperature ranges and process requirements.
-
Product
Analysis System
Trident (EDS-EBSD-WDS)
-
The Trident Analysis System combines the latest advances in Energy Dispersive Spectroscopy (EDS), Electron Backscatter Diffraction (EBSD), and Wavelength Dispersive Spectrometry (WDS) in a single analytical tool. With the Smart Features included in the easy to use EDAX analysis software, each technique can be optimized and used independently or they can be combined to provide seamless integration, resulting in comprehensive data collection that can then be shared between the different techniques.
-
Product
Testing for Si Solar Cells Using High Performance CCD
EL Imaging Tester
-
EL Testing for Si Solar Cells using High Performance CCD. The determination of luminescence (photo emissions) in solar cells is an important characterization tool. Typical solar cells often have defects which limit the efficiency or lifetime of a cell. Many of these defects are visualized with Luminescence Imaging. By using this technique, the manufacturing process can be optimized to produce better cells. Luminescence Imaging takes advantage of the radiative inter-band recombination of excited charge carriers in solar cells. The emitted photons can be captured with a sensitive CCD camera to obtain an image of the distribution of the radiative recombination in the cell. This distribution is determined by the local excitation level, allowing the detection of electrical losses, thus mapping the diffusion length of minority carriers as the emitted light is low intensity and in the near infra-red range, the CCD camera has a high sensitivity wavelength from 900 to 1100 nm with little thermal noise. This CCD camera provides excellent resolution of 1024 x 1024 pixels with a large 1μm pixel size, multi-megahertz readout speed, and robust USB 2.0 connectivity. The EL CCD Camera is the ultimate high-performance CCD camera for electroluminescence and photoluminescence imaging for Photovoltaic (PV) Cells and Modules. This camera combines low noise electronics and optimal sensitivity in NIR.
-
Product
Spectral Radiant Flux / Luminous Flux Calibration Standards
-
Standard lamps calibrated in luminous flux and spectral radiant flux. Versions with 2-Pi and 4-Pi emission characteristics. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
Scatterometers / Thin film Metrology Systems
Olympian Series
-
DUV-Vis-IR (Wavelength Range: 190nm – 15,000nm) Scatterometers / Thin Film Metrology Systems: The n&k Olympian, n&k Olympian-450 and n&k Olympian-M are DUV-Vis-IR scatterometers/thin film metrology systems with micro-spot technology, covering the wavelength range from 190nm – 15,000nm. With the inclusion of the infra-red wavelength range, the Olympian Series extends the capabilities of n&k’s DUV-Vis-NIR scatterometer series – the OptiPrime-CD Series.
-
Product
Portable Light Sources
FOD 2113
-
The FOD 2113 provides three wavelengths: 1310&1550 nm in one port and 850 nm 10mW in another port. Available adapter types: FC, SC, ST, Universal 2.5mm. All adapters are changeable
-
Product
Two-wavelength SM WDMs
-
Wavelength Division Multiplexers (WDMs) are used to combine or split two different single mode signals with low insertion loss. Thorlabs' WDMs featured on this page are manufactured using Fused Biconic Taper (FBT) technology and are designed for common NIR and telecom wavelengths (see the table to the right for options). They are an ideal solution for combining pump and signal wavelengths in fiber lasers and amplifiers or for combining telecom signals. Our WDMs have undergone extensive testing to ensure they meet or surpass Telcordia requirements; please see the Reliability Testing tab for details.
-
Product
Multi-Channel X-Ray Fluorescence Spectrometer
FACTORY LAB MXF-2400
-
Wavelength Dispersive X-Ray Fluorescence Spectrometer The Shimadzu MXF-2400 is an improved version of the Shimadzu Multi-Channel X-ray fluorescence spectrometer, which has been rated highly in the overseas market as well as in the Japanese market. The latest hardware designed to fully utilize the principle of X-ray fluorescence spectrometry and the data processing unit that uses various software programs to permit automatic management of analysis data combine to provide high analytical productivity both in R&D and production control. Up to 36 elements can be simultaneously determined by the fixed monochrometer and up to 48 elements can be determined sequentially by the optional scanning monochrometer. High analytical precision is provided even in high sensitivity analysis of a few ppm quantity level.
-
Product
High-Dynamic-Range Polarimeters
-
*Three Wavelength Ranges Available**400 nm - 700 nm**600 nm - 1080 nm**900 nm - 1700 nm*Rotating-Wave-Plate-Based Measurement*High Dynamic Range of 70 dB*Excellent Azimuth and Ellipticity Accuracy of ±0.25°*Sampling Rate up to 400 Samples/s*Beam Terminates Inside the Module*Ø3.0 mm Free-Space Beam Input or FC/PC Fiber Input *Fully Featured Software Includes Alignment Tool and Extinction Ratio Measurement Tool
-
Product
Single-Port Tunable Laser System Source
N7711A
Laser Source
The Keysight N7711A and N7714A tunable lasers are single-port and four-port sources, available with C-band or L-band wavelength coverage. The narrow linewidth and offset grid fine-tuning capability make them ideal sources for realistic loading of the latest transmission systems. All models can reach any wavelength point within their specified wavelength range just like all other Keysight tunable lasers. In this mode, code compatibility with existing test setups based on Keysight's range of full-size and compact tunable lasers is a great asset. In system loading applications, it may be preferable to grid-tune the lasers like system transmitters, simply by changing the channel index. The channel grid is adjustable to standard ITU-T grid spacing like 50 GHz, and to arbitrary grids. Likewise, the zero frequency (base channel) of the chosen grid is adjustable. A 12 GHz fine-tuning range allows de-tuning the frequency.
-
Product
10 Micron Wire Grid Polarizer
-
Fabricated from 10 micron diameter tungsten wire, and with a choice of wire spacing starting from 25 microns, these wire grid polarizers are suitable for use from approximately 100 microns (or 3 THz) to longer wavelengths. Please refer to the table below for the standard availability of wire spacing and frame clear aperture / outer diameter.
-
Product
Calibration Sources
-
Up to an absolute accuracy of 60 MHz standard HighFinesse Wavelength Meters feature auto-calibration by integrated calibration sources. This way highest accuracy and stability of measurements with our wavemeters is guaranteed.
-
Product
Loss Meter
L2000
-
3-in-1 as loss meter, light source, and power meter As loss meter Measure fiber loss at 1310nm and 1550nm As light source Single-head selectable output wavelength of 1310 or 1550 nm Ultra high output stability 0.05dB High output power preset at 0 dBm, or at customer-defined value Selectable CW, 270 Hz, 1KHz or 2KHz modulated output As power meter Calibrated outputs at 850, 1310, 1490, 1550, and 1625nm Data storage, logging, and PC up-loading Interactive measurements via PC Calibration on-site with customer's own standard if needed Selection of relative/absolute power measurement Display measurement in dB, dBm, mW, uW, nW Resolution 0.01dB; absolute accuracy 0.25dB For both single-mode and multi-mode optical fiber Small size, easy for field applications Light weight, less than 0.2Kg Auto power shut-off Enable / Disable Auto laser shut off at above 60oC Rechargeable battery, Battery-full and Battery-low indicator Changeable receptacle connector FC, SC, ST
-
Product
Infrared Laser Diode Modules: 830nm-852nm, Elliptical Beam
-
The Optoelectronics Company Ltd
Custom lasing wavelengths, from 405 nm to 852 nm, output power options and laser engraving are available to your specifications. Both standard and custom configurations provide OEMs, end-users and systems integrators with complete cost-effective laser solutions.
-
Product
Laser Power And Energy Meters
-
Measure laser power and energy with ease and precision over a huge range of wavelengths, power levels, and pulse energies.
-
Product
Fixed Wavelength CW Laser Source (FP) - PXI
Laser 1100 Series
Laser Source
The Laser-1102 is a Continuous Wave (CW) laser source offering high power 850 nm output into multimode fiber with stable output power operation.
-
Product
Bench-top Stabilized Laser Source
JW8001
-
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW8001 Bench-top stabilized laser source can satisfy the multiple needs of customers and achieve single wavelength output through unique automatic power control (APC) technology, automatic temperature control (ATC) technology and high stability output power and wavelength stability. It is an ideal instrument for scientific research and production, which requires a large range of attenuation variation, stable power and wavelength. It is widely used in the fields of scientific research, production and Engineering of optical communication, transmission and optical fiber sensing.
-
Product
Spectrometers
FREEDOM
-
The FREEDOM platform is a series of cost-efficient, pre-configured compact OEM spectrometers for the UV, VIS and NIR wavelength ranges that provide:*High sensitivity/optical throughput due to our in-house produced fused silica transmission gratings*Proven, environmentally robust, and thermally stable opto-mechanical benches with low unit-to-unit variation*Volume manufacturing with high quality, consistent performance and flexible delivery*A dedicated OEM support team to assist you throughout your project development and manufacturing phases*Senior level optical and mechanical design experience
-
Product
Single Photon Detector System For Near-Infrared (1.6-2.3 Um Wavelength) Waves With Liquid Helium (LHe) Cryostat
-
Insight Product Company is proud to offer Single Photon Detector System for Near-Infrared (1.6-2.3 um wavelength) with Liquid Helium (LHe) Cryostat. Insight Product Co. offers superconducting single photon detectors and ultra-low noise registration systems for the near infrared range. All systems operate in continuous mode, no gating required.
-
Product
Optical Rackmount Systems
-
DiCon offers a variety of rack-mountable solutions for fiber optic switching, test automation, and wavelength management. With standardized or customizable options, our platforms can be easily configured to work in different environments. DiCon's systems feature low insertion loss, excellent reliability, and durability. Applications include fiber optic testing and measurement, fiber based sensing, optical network configuration and monitoring.
-
Product
Multi-Band Imaging
-
Bodkin Design & Engineering, llc
A multi-band camera provides high-resolution, co-registered visible and infrared imagery through a common aperture telescope, unlike conventional visible or infrared cameras that provide image data in limited wavelength bands. Bodkin Design has created the Omnispotter multi spectral camera to enable the user to better discriminate targets from both background and decoys by blending color images with information from the IR band. The images obtained from this system penetrate darkness, camouflage, smoke and clutter better then either visible or IR images could alone.
-
Product
Random Access Monochromator
DeltaRAM X
-
The patented DeltaRAM™ X microscope Illuminator is the ideal fluorescence illuminator for quantitative intracellular ion research. It utilizes a galvanometer-based Random Access Monochromator (RAM) that can switch between any wavelength in 2 milliseconds. The DeltaRAM™ X is a complete, self-contained, illuminator that includes a power supply, high intensity xenon light source, DeltaRAM™ X monochromator, TTL shutter and flexible liquid light guide. The wavelength position is a simple analog voltage control. All you need to add is a microscope adapter for your fluorescence microscope and a USB or PCI DAC interface depending on the software you will be using to drive the illuminator.
-
Product
Attenuators
-
OZ Optics offers a broad range of both variable and fixed attenuators having key competitive advantages. All of our attenuators operate over the two standard wavelength bands, the C-Band and the L-Band. This wide wavelength range makes these components ideal for DWDM applications. Our attenuators are wavelength insensitive, which means they operate with minimal changes in attenuation when used in either the C-Band or the L-Band and exhibit low return loss. In addition, all of our attenuators have a wide attenuation range, which means they operate at a wide range of power levels. This is important as increased power levels are being used in newer optical systems.
-
Product
Spectroradiometers
-
Konica Minolta Sensing Americas, Inc
Spectroradiometers are instruments that scan different regions of the light spectrum, providing simultaneous representations of amplitude versus wavelength of the spectrum.
-
Product
Configurable & High Density Signal Transport
VF-9000 Series
-
Life on a mobile production truck or ENG van means making the most of your surroundings. With limited real estate for technology, our customers need high-density platforms to manage the abundance of signals coming in and going out. MultiDyne’s VF-9000 Series is built for high-pressure sports, news and live event production scenarios, and high-capacity transport requirements between studios and across campuses. The VF-9000 Series is also remarkably intelligent, providing automatic configuration of video inputs and outputs based upon recognizing which VF-9000 SFP modules are added to the frame. Hot-swappable modules establish redundancy to ensure live mission-critical operations are never disrupted, while data transport, video signal regeneration and wavelength shifting add value for users seeking a brute-force, rock-sold signal trunking and fiber transmission solution.
-
Product
Optical Multimeter
FPL300 Series
-
Shanghai Tarluz Telecom Tech Co., LTD
FPL300 Series Optical Multimeter integrates a stable optical laser source and a precise optical power meter. The optical laser source unit launches the laser whose wavelengths are at 1310/1550nm. The optical power meter unit can recognize the wavelength automatically. FPL3 Series Optical Multimeter offers a large storage capacity; With the assorted software, user can generate a report or manage the test report easily.
-
Product
SiTek UV PSD
-
The UV PSD is a detector optimized for use in the UV wavelength region 200-400 nm, although its spectral response reaches up to 1100 nm. The sensitivity in the UV region (200-400 nm) is extremely high. The UV-PSD has the same outstanding specifications as the standard SiTek PSD.
-
Product
Radiometers For Laser Radiation
-
Laser Power Meters, Radiometers, Dosimeters and Data Loggers for Irradiance, Laser Power, Laser Energy and Pulse Shape in the 400 nm - 1800 nm Wavelength Range.
-
Product
PED Systems
Pulsed Electron Deposition
-
Is a process in which a pulsed (80-100 ns) high power electron beam (~1000 A, 15 kV) penetrates approximately 1 μm into the target resulting in a rapid evaporation of target material. The non-equilibrium heating of the target facilitates stoichiometric ablation of the target material. Under optimum conditions, the target stoichiometry is preserved in the deposited films. All solid state materials – metals, semiconductors and insulators, including those transparent to laser wavelengths in PLD – can be deposited as thin films with PED. By combining PLD and PED, the range of complex materials that can be prepared as thin films can be greatly enhanced.