Protocol Simulation
-
Product
PXI 6-Channel Battery Simulator Module
41-752-001
Simulator
The 41-752 is a 6 channel battery simulator, each channel being capable of supplying up to 7V and 300mA to the load. Each channel is fully isolated from ground and from each other allowing the channels to be connected in series to simulate batteries arranged in a stacked architecture. The 750V isolation barrier permits the 41-752 to be used to create a lower power version of a battery stack representative of those used for vehicle propulsion.
-
Product
PXI RTD Simulator Module 18-Channel PT1000
40-262-002
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
PCIe 5.0 Protocol Analyzer
P5552A
Protocol Analyzer
The Keysight P5552A PCIe 5.0 Protocol Analyzer introduces a new form factor that is easily deployable in the lab bench environment to enable deep protocol analysis of a PCIe system with unparallel signal integrity. Locate protocol errors or validate device operations by viewing data from the physical layer all through the transactional layer with ease.
-
Product
PXI Strain Gauge Simulator Module 6-Channel, 2k
40-265-306
Strain Gauge Simulator
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 6-channel, 2kΩ) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
Product
PXI RTD Simulator Module, 24 Channel, PT500
40-263-002
Simulator
The 40-263-002 is a 24-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module 12-Channel PT1000
40-262-202
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
PXI/PXIe Battery Simulator Module, 2-Channel, 1 kV Isolation
41-752A-103
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
PXI Battery Simulator Module
41-750-001
Simulator
The 41-750 is a battery simulator module that can be used to simulate the power supplies of cellular phones and other portable battery devices. It features fully floating output terminals than can deliver voltages up to 6 Volts. The fast responding remote sense connections allow the module to regulate the supply voltage at the device under test.
-
Product
PXI RTD Simulator Module, 12 Channel, PT500
40-263-302
Simulator
The 40-263-302 is a 12-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
3U cPCI Synchro/Resolver Simulation Board
75DS2
Simulator
NAI’s 75DS2 is a Synchro/Resolver Simulation Board with four independent, isolated channels. These channels can incorporate up to four Digital-to-Synchro/Resolver Simulation Converters with 1.5, 2.2, or 3 VA drive capability, or either two or four Digital-to-LVDT/RVDT Simulation Converters. One of the outputs on each channel can be grounded without affecting performance.
-
Product
PXI/PXIe Battery Simulator Module, 6-Channel, 1 KV Isolation
41-752A-101
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture. The 750 V or 1 kV isolation barrier (version dependent) allows the module to be used as a lower power version of a battery stack, representative of those used for vehicle propulsion.
-
Product
Protocol Analyzer / Jammer for PCI Express 5.0
Summit M5x
Protocol Analyzer
The Summit M5x is Teledyne LeCroy's PCIe/ NVMe Jammer solution and is the latest protocol analyzer targeted at high speed PCI Express 5.0 I/O-based applications such as workstation, desktop, graphics, storage, and network card applications.
-
Product
PXI Isolated Millivolt Thermocouple Simulator - 32 Channel
41-761-001
Simulator
The 41-761-001 is a low voltage 32-channel output module ideal for simulating theoperation of a thermocouple, also available with 24, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
Product
PXIe Battery Simulator Module, 4-Channel, 5 Amp
43-754-011
Battery Simulator
The 41-754-011 and 43-754-011 are 4 channel battery simulators, capable of supplying up to 8 V and 5 A per channel. The channels are fully isolated from ground and from each other allowing series connection to simulate batteries in a stacked architecture. The isolation barrier (1000 V channel to GND and 750 V channel to channel) allows the module to be used as a battery stack representative of those used for vehicle propulsion..
-
Product
Protocol Analyzer / Exerciser
Summit M616
Protocol Analyzer
The Summit M616 is Teledyne LeCroy's latest generation of protocol analyzers targeted at high speed PCI Express 6.0 and CXL I/O-based applications such as server, workstation, desktop, graphics, storage, AI, and network card applications.
-
Product
LED Load Simulator
63110A/ 63113A/63115A
Simulator
As shown on the V-I curve in figure 1, the LED has a forward voltage VF and a operating resistance (Rd). When using a resistor as loading, the V-I curve of the resistor is not able to simulate the V-I curve of the LED as shown in blue on figure 1. This may cause the LED driver to not start up due to the difference in V-I characteristic between the resistors and the LEDs. When using Electronic Loads, the CR and CV mode settings are set for when the LED is under stable operation and therefore, is unable to simulate turn on or PWM brightness control characteristics. This may cause the LED driver to function improperly or trigger it’s protection circuits. These testing requirements can be achieved when using a LEDs as a load; however, issues regarding the LED aging as well as different LED drivers may require different types of LEDs or a number of LEDs. This makes it inconvenient for mass production testing.
-
Product
Grid Simulators
Simulator
A grid simulator can be used to simulate the characteristics of low-voltage mains. For this purpose, all voltages and frequencies of the supply networks occurring worldwide can be simulated. Critical states such as short-term voltage dips or voltage peaks (surge/burst) can also be generated.The integrated sequencer function enables the generation of different network parameters, e.g. distorted waveforms and intermediate oscillations. Therefore, grid simulators are well suited for testing conformity to standards and especially for determining the behaviour of electrical equipment in borderline situations. Many European and other international standards are pre-programmed for testing.
-
Product
Portable Range Threat Simulators
Simulator
The Textron System's PRTS™ and HPRTS™ are medium and long-range, programmable, ruggedized Radio Frequency (RF) test and training tools. Our PRTS family of range simulators delivers high-fidelity environments for training ranges.
-
Product
ARINC825 (CAN Bus) Test & Simulation Module for PCI With 2 Or 4 CAN Bus Nodes
ACP825-x
Simulator
ARINC825 (CAN bus) Test & Simulation module for PCI with 2 or 4 electrically isolated CAN bus nodes operating concurrently at CAN bus high speed bit rate of up to 1Mbit/s. The ACP825-x PCI card can work either with full functionality as an active CAN node for testing and simulating or in Listening Only mode for monitoring and recording purposes.
-
Product
PXI Strain Gauge Simulator Module 6-Channel, 350
40-265-016
Strain Gauge Simulator
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 6-channel, 350Ω) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
Product
PXI Strain Gauge Simulator Module 2-Channel, 3k
40-265-102
Strain Gauge Simulator
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 2-channel, 3kΩ) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
Product
Protocol Analyzer
-
Zeroplus Technology Corperation
Is a measurement tool or device used to capture and monitor the data over communication channel.
-
Product
PXI/PXIe LVDT/RVDT Simulator Module, 2-Banks
41-670-103-AABBCC
Simulator
The 41/43-670-103 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types. It has two banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 2 channels of 5 or 6-wire or 4 channels of 4-wire.
-
Product
PCI Strain Gauge Simulator Card, 2-Channel, 1k
50-265-202
Strain Gauge Simulator
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
4, 8, 16 And 32 Channels ARINC429 Test & Simulation Module CompactPCI/PXI (3U)
ACXX429-3U-x
Simulator
The ACXX429-3U-x is a functional replacement formodel ACX429-3U-x.
-
Product
DOCSIS Protocol Analyzer
XRA-31
-
Fast DOCSIS® 3.1 testing and communication troubleshooting is a must to ensure your network is performing the way it should. The key to easy, lighting-fast analysis? Our XRA-31 real-time DOCSIS protocol analyzer. Featuring an exceptionally intuitive GUI, the XRA-31 makes packet capture and analysis a smooth, quick, and pleasant experience – to help you pinpoint issues in no time.
-
Product
PXI Strain Gauge Simulator Module 2-Channel, 1.5K
40-265-402
Strain Gauge Simulator
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 2-channel, 1.5Ω) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
Product
Protocol Control Control
PC2
-
The PC2 software from SCSI Toolbox, LLC brings a new level of parallel SCSI protocol control to your test environment. Designed in cooperation with LSI Logic to work with their Fusion-MPT Message Passing Interface technology, PC2 allows all negotiated parameters to be displayed or set for all devices connected to any SCSI Host Bus Adapter based on the LSI53C1030 chip set. PC2 also provides the means to generate hardware SCSI bus resets.
-
Product
Protocol Analyzers
-
International Test Instruments Corp.
The Bus Analyzer, is capable of capturing and decoding real-time LS, FS and HS USB Transactions as well as OTG SRP, OTG HNP and OTG VBus events. It has unlimited capture length (only limited by the RAM in the analysis PC as the captured data is viewed), immediate display of very large recorded capture data (data is streamed in real-time into the tree view as it is captured from the link under test or from file so you will not have to wait before you can start analyzing the data) as well as a very small physical format which makes it a powerful companion in your laptop bag or in the lab.
-
Product
PXI/PXIe Battery Simulator Module, 2-Channel, 750 V Isolation
43-752A-003
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.





























