Current Shunts
Resistors with known accurate values to measure current.
See Also: Shunts, AC Current Shunts
-
product
PXI/PXIe Wide Current Range Multiplexer Module, Single 12-Channel, 2-Pole
42-514-105
The 40-514-105 (PXI) and 42-514-105 (PXIe) are low density multiplexers in single 12-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
PXI/PXIe Battery Simulator Module, 6-Channel, Simplified Current Sink, 750 V Isolation
41-752A-901
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
product
12-Ch SPST 4A-250VAC 24VDC High Current Power Switching
YAV90PIN
The YAV90PIN board is designed to cover the need to control the available power supplies in a test system to the device under test. A VPC 90 series connector is used as interface with the fixture, guaranteeing more than 20.000 mating cycles. Two connector contacts per relay contact are used.
-
product
16 SE Or 8 Diff. Input Channels, 4 Analog Current Output Channels, PCI Express
APCIE-3121-16-4C
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
product
Current Transformer
ST-9RCT
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 800~2000
-
product
Air Core Current Limiting Reactors
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
product
Low Voltage High Current DC Electronic Load
N62400 Series
Next Generation Instrumental (Shanghai) T&C Tech. Co., Ltd.
N62400 series is developed based on NGI's years of experience in testing for fuel cell. It is with high accuracy, high reliability and high cost-effective. N62400 series is with high power density and elegant appearance, which is available for benchtop use or installation in 19 inch cabinet.
-
product
Rogowski AC Current Probe
RCP500
Shenzhen Micsig Instruments Co., Ltd.
Adopts the Rogowski coil current measurement system: within the range, the output signal of the system and the current signal to be measured are always linear, so the accuracy will not change with the current; The RCP500 measures AC current up to 500A pk, minimum to 200mA pk, with bandwidth ranging from 15Hz to 300KHz, 1% accuracy, and has less than 2mV noise. Directly powered by Micsig UPI interface, realise auto scaling setup,
-
product
Multi-Channel, Programmable Current Source
CS-48-100
The Model CS-48-100 is a multi-channel, programmable current source. Developed for both semiconductor and digital superconductor electronics, it is computer-controlled and features 48 low noise current source outputs. Each source output has the capability to both set and read back currents and can be set to a zero current high Z mute state. Each of the 48 sources are optically coupled for control and are sourced from their own secondary winding for complete galvanic isolation. The device consumes a maximum of only 80 W and handles a maximum load current of 4.8 A total over all outputs. Operating over a range of 0-100 mA on each channel, the device features accuracy of +/-25 ?A. The mute state can be set thru a rear panel interlock or from the front panel button for maximum circuit protection. The unit can be mounted in a standard-sized rack.
-
product
AC/DC Current Clamp Meter
CM100
Small jaw: 1.2"(W) x 0.53" (D) (300x13.4mm). Clamp opens up to 1/2 inch (12.5 mm). One rotary switch operation. Large 4 digit LCD display. AC/DC Voltage measurement up to 600 Volt. AC/DC current measurement from 0.001 up to 100 A. Relative measurement. One touch auto zero
-
product
L Terminal Shunt Resistor
LT
LT shunts are highly accurate manganin resistance D.C. shunts. These shunts are designed for standard current measurement of electric equipment.
-
product
Current Measurements Of PWM Or Inverter, AC/DC 1~50A, Φ16mm
CTF-50DC-U24V
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 1~50A*Current measurements for PWM or inverter
-
product
Flexible Rope-Type Current Probe
RCT1A and RCT5A
These probes have great bandwidth ensuring accurate measurement even with harmonically distorted wave shapes. For all RCT1A/RCT models, a NIST, NAVLAP, NPL (UKAS) factory traceable calibration certificate and certificate of conformance is supplied. UL/CSA approved materials are used throughout. Three phase and single phase flexible AC current sensors (rope sensors) are available for fast installation in confined spaces, eliminating the need for Electrical Supply Shutdown. Available outputs are 1A @ 2.5VA and 5A @ 0.5VA, this means long cable lengths from current sensor to signal conditioner allow these low VA ratings to be used, even when feeder cable to energy meter distances are large (up to 98 feet / 30 meters)
-
product
Electrolytic Capacitor Leakage Current Meter
TH2686C
Changzhou Tonghui Electronic Co., Ltd.
■ Test voltage: 0-200V, 0-500V ■ Voltage accuracy: 2% set value + 2 words ■ Measuring range: 0-30mA, 10 gears ■ Current accuracy: 2% of reading +0.5 grid
-
product
L.V. Current Transformers
ENTES LV Current Transformers are measuring transformers which transform the primary current by a specified ratio to its secondary side with a phase difference of 0 degrees. They provide isolation of the relays and measuring devices from the HV side of the network.
-
product
PXI/PXIe Wide Current Range Multiplexer Module, Quad 6-Channel, 1-Pole
42-514-106
The 40-514-106 (PXI) and 42-514-106 (PXIe) are low density multiplexers in quad 6-channel, 1-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
Primary Current Injection Tester
SLQ
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
It's a high voltage generator insutrment for tesitng.
-
product
Digital Current Integrator
The ORTEC Model 439 Digital Current Integrator was designed to accurately measure DC currents or the average value of pulse currents such as produced by accelerator beams. It digitizes the input current by producing an output pulse for specific values of input charge. A front-panel switch permit the selection of three different amounts of charge (10–10, 10–8 or 10–6 coulomb) required to produce an output pulse. The instrument has a digitizing rate from 0 to 10 kHz to provide wide dynamic range on each setting and high-resolution readout without meter interpolation.
-
product
Current Clamps and Sensors
Are designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. It is specially designed to detect low fault currentson power circuits.
-
product
Split type AC Current Transformer
CTS-300
MULTI MEASURING INSTRUMENTS Co., Ltd.
*5A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy to install by metal fitting.
-
product
Broadband Current Probes
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on broadband current probes. The BCP-5xx EMC Current Probes are designed to permit field intensity meters, spectrum analyzers, and other 50W impedance instruments to measure quantitative magnitudes of current.
-
product
Primary Current Injection Test Trolley
SCR ELEKTRONIKS have developed primary and secondary Current injection test trolley for Switchgear manufacturers for testing of ACB , MCB , MCCB. It is low Voltage high Current source with control circuitry, digital read out for test current and trip time measurement. We can select different links of CT range as per the required test Current.
-
product
Clamp type AC Current Sensor/for Low Leakage Current Measurements(ZCT Series)
ALCL-40D
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Best sensor for micro ampere current measurements.*Super high accurate sprit type ZCT sensor.*High sensitivity and least affection from external magnetic field. (less than 10μA for 400A nearby conductor)*For leakage current measurements of arrester.*Stable measurements under high electric field and strong magnetic field.
-
product
Fuse Buddy Current Loop
307M/308B
*Just clamp your current probe over the loop to access the amperage draw through a fused circuit. *Easy testing access, plugs right into fuse socket, no more hand made adapters. *Testing range 0-30 Amps - Do Not Exceed 30 Amps
-
product
Leakage Current Tester and Clamp-On Earth / Ground Resistance Tester
10µA Ultra High ResolutionLarge Conductor Diameter (30mm)AC Current in 5 Ranges (40mA, 400mA, 4A, 40A, 60A)Wide Frequency Response (40Hz-1KHz)ACA, ACV, Ω and ContinuityLarge 3¾ Digit LCD (4000 Count)40 Segment Fast Bargraph Display (20 times/sec.)Data Hold and Max / Min HoldRelative Measurement600 Vrms Overload Protection in Resistance Range
-
product
Primary & Secondary Current Injection Testing Sets
Primary current injection kits are used to test and commission Circuit Breakers, Bus Bars, CTs, Relays, MCCs, PCCs etc. These are also used for high current injection and simultaneously measuring voltage drops and hot spots in bus-bar joints, Circuit Breaker Contacts etc.
-
product
Current Probe
PA-677
*Max. 70ADC/140Ap-p*Sensitivity: ≧2mA*Bandwidth: DC~1MHz*Rise Time: 0.35μS*Over Range Function*50mV/A, 500mV/A Range*Adaptor/Battery Input*Separating Design,Convenient Durable
-
product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 6-Channel, 2-Pole
42-514-104
The 40-514-104 (PXI) and 42-514-104 (PXIe) are low density multiplexers in dual 6-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
16-Ch SPST 10A-277VAC High Current
YAV90086
16 power relays SPST Switching up to 2770VA 16A Switching 125Vac 10A Switching 277Vac CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available





























