Signal Generators
Generate repeating analog or digital electronic signals.
See Also: Signal, Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Conditioning, Signal Meters, Signal Conditioners
-
product
PXIe-5663E, 6.6 GHz PXI Vector Signal Analyzer
781339-03
6.6 GHz PXI Vector Signal Analyzer - The PXIe‑5663E offers wide instantaneous bandwidth and supports RF list mode, which increases multiband measurement speed with fast and deterministic changes in configuration. You can use a PXIe‑5663E as either a spectrum analyzer or vector signal analyzer, and you can use it with the Modulation Toolkit to analyze custom and standard modulation formats. The PXIe‑5663E can perform measurements for a broad range of communications standards such as GSM, EDGE, WCDMA, WiMAX, LTE, Bluetooth, WLAN, DVB‑C/H/T, ATSC, and MediaFLO. Because all measurements are software defined, you can reconfigure the measurements using standard-specific toolkits. With these toolkits, the PXIe‑5663E provides a low-cost solution to high-performance RF measurements.The PXIe-5663E comprises the following modules:• PXIe-5601 RF Signal Downconverter• PXIe-5622 IF Digitizer• PXIe-5652 RF Analog Signal GeneratorThere is no physical device named "PXIe-5663E".
-
product
Signal, Patchcord, Receiver, 72", QuadraPaddle, 22 AWG White, Single Ended (5 Amps)
7-124922000-072
Signal, Patchcord, Receiver, 72", QuadraPaddle, 22 AWG White, Single Ended (5 Amps).
-
product
Signal, Contact, Receiver, TriPaddle, 7 Amp, 26-28 AWG
610110167
Primary mating contact 610110169. (May mate with other ITA contacts, as well.)Specifications Operating Voltage & Current 7 Amps Max. Continuous (20 AWG)600 Volt Max. use of wire Mil-W-16878/4Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 4000 MOhms Min.Contact Body BeCuContact Plating 30µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs.) 0.41
-
product
125MS/s PXIBus Arbitrary Waveform Generator
5201
Model 5201 is a Single-Channel Arbitrary Waveform / Function Generator that combines many powerful functions in one small package. Supplied free with the instrument is ArbConnection software, which is used for controlling the 5201 and for generating, editing and downloading waveforms from a remote computer.
-
product
HD Arbitrary Waveform Generator, 2 Ch, 350 MHz, 16 bit, 128Mpts/Ch, 6 Vpp output, Wave Sequencing
T3AWG3352
HD Arbitrary Waveform Generator, 2 Ch, 350 MHz, 16 bit, 128Mpts/Ch, 6 Vpp output, Wave Sequencing.
-
product
PXI-5421, 43 MHz Bandwidth, 16-Bit PXI Waveform Generator
778697-02
43 MHz Bandwidth, 16-Bit PXI Waveform Generator—The PXI‑5421 is a 43 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms. The PXI‑5421 also features advanced synchronization and data streaming capabilities.
-
product
USB Modular Function Generator
U2761A
Keysight U2761A is a 20 MHz function generator that offers 10 standard waveforms plus pulse and arbitrary waveforms generation capabilities.
-
product
PXIe-5665, Up to 14 GHz PXI Vector Signal Analyzer
781774-03
Up to 14 GHz PXI Vector Signal Analyzer - The PXIe‑5665 is a modular, three‑stage superheterodyne analyzer that you can use as either a spectrum analyzer or vector signal analyzer. It supports RF list mode, which increases multiband measurement speed with fast and deterministic changes in configuration. In addition, you can use the PXIe‑5665 with the Modulation Toolkit to analyze custom and standard modulation formats. The PXIe‑5665 can perform measurements for a broad range of communications standards such as GSM, EDGE, WCDMA, WiMAX, LTE, Bluetooth, WLAN, DVB‑C/H/T, ATSC, and MediaFLO. Because all measurements are software defined, you can reconfigure the measurements using standard-specific toolkits. With these toolkits, the PXIe‑5665 provides a low-cost solution to high-performance RF measurements.
-
product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1P1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Alternate 3.50 (99.00) - 6.85 (194.00) General Purpose Probe
P2757G-1R2S
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
product
Signal, Contact, Receiver, QuadraPaddle, 5 Amp, 22-28 AWG, 50µ” Au, Crimp
610138116
*Please note: The difference between this p/n and 610138216 is the amount of gold plating. See below.P/n 610138116- 50µ" AuP/n 610138216- 30µ" AuPrimary mating contact 610138112. (May mate with other ITA contacts, as well.)Specifications Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body BeCuContact Plating 50µ" Au over 100µ" NiCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force(lbs) 0.24
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1G
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
65 GSa/s Arbitrary Waveform Generator
M8195A
Sample rate up to 65 GSa/s High channel density: 1, 2 or 4 channels per module, synchronization of up to 16 channels on 4 modules with the M8197A multi-channel synchronization module Built-in frequency and phase response calibration Embedded DSP enables real-time waveform and impairment generation(in conjunction with the 81195A optical modulation generator software)
-
product
FieldFox Handheld Microwave Signal Analyzer, 32 GHz
N9960B
A lightweight, durable, software-enabled, microwave signal analyzer, interference analyzer, distance-tracking generator, preamplifier, power meter, and more.
-
product
PXIe-5665, Up to 14 GHz PXI Vector Signal Analyzer
781775-03
Up to 14 GHz PXI Vector Signal Analyzer - The PXIe‑5665 is a modular, three‑stage superheterodyne analyzer that you can use as either a spectrum analyzer or vector signal analyzer. It supports RF list mode, which increases multiband measurement speed with fast and deterministic changes in configuration. In addition, you can use the PXIe‑5665 with the Modulation Toolkit to analyze custom and standard modulation formats. The PXIe‑5665 can perform measurements for a broad range of communications standards such as GSM, EDGE, WCDMA, WiMAX, LTE, Bluetooth, WLAN, DVB‑C/H/T, ATSC, and MediaFLO. Because all measurements are software defined, you can reconfigure the measurements using standard-specific toolkits. With these toolkits, the PXIe‑5665 provides a low-cost solution to high-performance RF measurements.
-
product
PXI Vector Signal Transceiver
The PXI Vector Signal Transceiver (VST) combines the flexibility of a software defined radio architecture and RF instrument class performance. You can use the VST to test a variety of cellular and wireless standards, and you can easily expand the VST's three-slot, 3U PXI Express form factor to support multiple input, multiple output (MIMO) configurations. The VST software is built on LabVIEW FPGA, and features several starting points for your application including application IP, reference designs, examples, and LabVIEW sample projects.
-
product
HD Arbitrary Waveform Generator, 2 Ch, 250 MHz, 16 bit, 128Mpts/Ch, 6 Vpp output, Wave Sequencing
T3AWG3252
HD Arbitrary Waveform Generator, 2 Ch, 250 MHz, 16 bit, 128Mpts/Ch, 6 Vpp output, Wave Sequencing.
-
product
Standard 0.50 (14.00) - 3.40 (96.00) Non Replaceable General Purpose Probe
C-S-C
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
product
Signal, Patchcord, Receiver, 36", TriPaddle, 22 AWG White Twisted Pair, Single Ended ( 5 Amps)
7-104422000-036
Signal, Patchcord, Receiver, 36", TriPaddle, 22 AWG White Twisted Pair, Single Ended ( 5 Amps).
-
product
9GS/s 16Bit 8GS Mem 12CH 8 Markers RF AWG Desktop
P94812D
The desktop version of the Proteus arbitrary waveform generator series offers up to 12 channels in a 4U, half 19” dedicated chassis. The compact form size and small footprint save valuable bench space. So for synchronized, phase coherent, multi-channel applications such as quantum physics and radar applications the Proteus arbitrary waveform transceiver is an ideal, space efficient, and cost effective solution.
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4A
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Waveform Generator, 20 MHz, 2-Channel
33510B
The 33510B waveform generator provides Keysight’s exclusive Trueform technology which offers unmatched capabilities for generating a full range of signals for your most demanding measurements.
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4D
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Arbitrary Function Generator
HMF2525/HMF2550
Powerful pulse generator Provides pulses with a recurrence rate of up to 12.5 MHz/25 MHz; the pulse width can be set from 15 ns to 999 s with a resolution of 5 ns. Rise/fall time can be selected from 8 ns to 500 ns – a very useful feature when characterizing input hysteresis of semiconductor devices Easily create arbitrary waveforms Arbitrary waveforms can be developed with PC software. Stored waveforms can be loaded via front USB port or imported via the complimentary HMExplorer software (available for download)
-
product
Signal, Patchcord, Receiver, 72", QuadraPaddle, 68-Pin Male SCSI
7-124883666-072
Signal, Patchcord, Receiver, 72", QuadraPaddle, 68-Pin Male SCSI.
-
product
Standard 0.50 (14.00) - 2.00 (57.00) Non Replaceable General Purpose Probe
A-A-S-R
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm
-
product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1V1S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Alternate 2.50 (71.00) - 5.80 (164.00) General Purpose Probe
P2665G-1R2S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Signal Generator
SGV4
The C.Scope SGV4 Signal Generator is designed for use alongside a CXL4 or DXL4 Cable Avoidance Tool. It enables significantly more underground utilities to be detected including street lighting cables.
-
product
Alternate 2.54 (72.00) - 6.20 (176.00) General Purpose Probe
HPA-52T-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98