Ground Strap
-
Product
Heavy-Duty Circuit Tester With Grounding Adapters
30610
-
Heavy-duty circuit tester with multiple options for connecting to a ground source. Long, 12’ cord has a quick coupler to securely connect clamp or power outlet plug. Large, strong clamp connects securely. Power outlet plug can always be used to provide ground in the cabin. For testing circuits up to 12 volts.
-
Product
Personal Grounding Tester
PGT120
-
Electronic test apparatus for checking personnel grounding systems such as electrostatic wrist straps and conductive footwear. The unit is equipped with two separate measuring circuits and is therefore capable of checking wrist straps and footwear separately or in parallel. The test result is signaled visually, acoustically (only if error is detected) and via contacts.
-
Product
ESD CONTINUOUS DUAL OPERATOR WRIST STRAP MONITOR
-
This economical continuous wrist strap monitor ensures that your wrist strap is in good working condition. Ensure wrist strap in good working condition
-
Product
Ground Resistance Tester
-
Weshine Electric Manufacturing Co., Ltd
1.Soil resistivity tester supports 2, 3 and 4wire grounding resistance measurement. 2. 4digit large LCD display with white screen backlight, suitable for use in dimly lit places. 3. IP65 protection grade, good waterproof, compact and portable, supports multiple functional tests.
-
Product
Stator Ground Protection Relay
SEL-2664S
-
Schweitzer Engineering Laboratories, Inc.
Protect high-impedance grounded generators from ground faults at standstill, during startup, and while running with the multisine frequency injection and neutral overvoltage-based protection in the SEL-2664S.
-
Product
Static Grounding for Process Plant & Equipment
Earth-Rite MULTIPOINT II
-
The Earth-Rite® MULTIPOINT II is a unique multi-channel static grounding system that can monitor the simultaneous grounding of up to eight (8) individual pieces of equipment at risk of discharging electrostatic sparks.
-
Product
High Resistance Neutral Grounding Devices
-
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
Product
12-bit, 4 Analog Voltage Outputs With Separate Grounds, Optically Isolated 500 V
APCI-3504
-
4 analog output voltage channels with 500V optical isolation, 12-bit resolution, each output has its own ground line.
-
Product
Static Grounding Protection for Tank Trucks
Earth-Rite RTR
-
Precision and reliability is what the Earth-Rite RTR provides to HAZLOC safety professionals and engineers who are tasked with protecting personnel and plant assets from the ignition hazards of static electricity during tank truck loading and unloading operations.
-
Product
3U VPX 4 Slot Power & Ground With 3x VITA 67.3C Apertures In P2/J2
101V304P12-9X13
-
The only assigned pins on these backplanes are for 3.3V, 5V and 12V power, and both ground and utility planes are defined. The remaining pins are all user-defined. The rear connectors are all fully populated.
-
Product
3U VPX 1 Slot Power & Ground 25G Pass Through
101VPX301P-9X13
-
Power for 3.3V, 5V and 12V are included, rear connectors are all fully loaded, use with Elma’s slot to slot or slot to I/O bulkhead cable products during system development.
-
Product
Generator Neutral Grounding & Leads Cubicles
-
Generator Neutral Grounding Cubicles are designed to minimize fault damage incurred by generators, maintain sufficient fault detection and improve power system reliability. Generator Neutral Grounding and Lead Cubicles are manufactured as for IEEE or IEC standards.
-
Product
Earth Ground Clamp
1630-2
-
The 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes.
-
Product
Neutrino Ground ISR
SX12 ISR1200
-
The Neutrino SX12 ISR1200 is the inaugural series model. With a 1280×1024/12 µm resolution focal plane array (FPA), a 120 mm to 1,200mm CZ lens, and advanced image processing, it is the ideal OEM camera module for integration into long-range ground ISR, perimeter surveillance, border surveillance, and counter-UAS (CUAS) systems.
-
Product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
-
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
Product
Ground Grid Tester
GGT Series
-
The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.