Infrared Calibrators
controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
Product
Carbon and Sulfur in Inorganic Materials by the Combustion Infrared Detection Technique
744 Series
-
LECO's 744 Series will redefine the way you determine carbon and sulfur in metals, ores and other inorganic materials. Using extensive customer feedback and innovative engineering, our latest instrumentation takes advantage of an immersive software platform that will increase usability and lower the cost-per-analysis.
-
Product
Infrared Thermometer
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
Thermometer which infers temperature from a portion of the thermal radiation sometimes called blackbody radiation emitted by the object being measured.
-
Product
Digital Infrared Thermometer
IR-100A
-
Shenzhen Calibeur Industries Co., Ltd..
'- Temperature Range: -20℃ ~ 220℃(-4~428℉);'- Resolution: 0.1℃/℉(for thermometer);1sec(for stop watch) ;'- Accuracy(Tamb=23±3℃): ±2% of reading or ±2℃(4 ℉);'- Field of View: 1:1; '- Emissivity: 0.95'- Size: 65mm*36mmm*19mm'- Weight: 26g'- Power: one CR2032 Lithium Cell Battery( not included)
-
Product
Microwave Measurements & VNA Calibrations
-
Rosenberger Hochfrequenztechnik GmbH & Co. KG
For microwave measurements and VNA calibrations, Rosenberger develops, manufactures, and provides test & measurement products which meet the highest demands of industrial test applications. These include high-performance VNA test cableswith outstanding phase and amplitude stability, a variety of test port adaptors for VNA applications up to 110 GHz, very robust interchangeable high mating cycle port connector systems, and test devices – from low-frequency devices for simple measurements to components permitting high-precision broadband measurements.
-
Product
Infrared CO2 Analyzer
CI-IN261
-
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
CI-IN261 is based on NDIR principle and adopts digital processing technology as zero point/range point calibration, linear processing, temperature compensation, switch output, flow/voltage output, parameters setting etc. - See more at: http://en.ci-ele.com/sf/a55f582e-1bef-4eac-b401-bf24b8f7e1c8.shtml#sthash.6RCIN6uu.dpuf
-
Product
Gasmet Calibrator
-
Gasmet portable calibrator is one of the most important tools in generating new applications for the Gasmet FTIR gas analyzer. The calibrator incorporates a syringe pump, a manual needle valve, a mass flow meter, and a stainless-steel injection chamber. The syringe pump injects precise amounts of liquid or gas into a hot nitrogen gas flow, thus producing a continuous flow of a known concentration calibration gas.
-
Product
CalPod Drive Cable Extension, 10 Meter
85554A
Calibration Cable
85554A CalPod Drive Cable (10 meter length) extends the length of CalPod control cables when the distance between the 85523B to the CalPod modules is >2 m.
-
Product
Portable Three Phas Multifunction Electric Meter Calibrator
GF312V2
-
Beijing GFUVE Electronics Co.,Ltd.
GF312V2 portable three phase multifunction energy meter calibrator is with comfort design, small size, and light weight. It is suit for electric power departments, measuring and quality examining departments and electric lab to field use.
-
Product
Ice Point Calibrators
-
These ice point calibrators are designed to accurately calibrate probes at the freezing point of water. These devices have multiple thermowells to calibrate multiple sensors simultaneously.
-
Product
Sound Level Calibrator
511E
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
OMNIR: On-Line Near Infrared Sensor
-
OMNIR is the future of near infrared moisture sensing technology. Coming from OMNI, meaning “all” and NIR, meaning “near infrared,” Finna Sensors has created an intelligent all-sensing solution that exceeds expectations. It not only delivers accurate data instantaneously and non-destructively, it also monitors its own health to perform its best during your crucial processing moments. By selectively harnessing light, to ensure increased uptime and greater profitability for your operation, the future of your manufacturing operation starts now.
-
Product
NIST Calibration for D420-A
D420-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Apex Series Calibration Kit
-
The APEX Series Calibration Kit provides calibration personnel the ability to re-certify the calibration of the APEX SL or APEX PRO control systems in-house. A simple Windows based program and an RS232 digital interface to a Keithley multi-meter, goes through system checks and verifications, and provides a detailed printed report of pass/fail, actual and expected values, and tolerances for each parameter checked.
-
Product
Voltage And Current Calibrator
-
Precision Mastech Enterprises Co.
A precision instrument designed to generate (source) and measure precise electrical signals.
-
Product
Automatic Calibration Module
ACM4509
-
ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
Product
Intrinsically Safe Calibrators
-
We offer calibrators that are Intrinsically Safe and can be used in hazardous Ex areas, where explosive gases may be present. Using Ex certified calibrators makes it easier for you, as it eliminates the need for always getting hot-work permits when going on site. Our Ex calibrators are both ATEX and IECEx certified.
-
Product
Calibration Lead - Precision Resistor Modules
40-975-037-1m
Cable Assembly
The cable assembly is specifically designed to connect to the 37-Pin D-Type calibration port located on the front panel of Pickering Interfaces Precision Programmable Resistor Modules 40-297 and 50-297 enabling calibration via an external DMM.
-
Product
ReCalibration and Post Calibration Software
SI58
-
The SI58 software allows the user to set zero and span as well as do full temperature compensation and linearity corrections for your Validyne USB pressure transducer. The SI58 provides everything needed to change the range of your transducer and calibrate it through the new full scale pressure. Corrections to non-linearity and temperature error are also possible. The SI58 software provides prompts to the operator for temperature and pressure points to achieve an accurate calibration.
-
Product
Uncooled Infrared Cameras and Sensors
-
Uncooled Infrared Cameras and Sensors by Lynred USA: XGA/SXGA Format, VGA Format, QVGA Format
-
Product
Torque Calibration
-
ISO 17025 Accredited Calibration for Torque Screwdrivers, Torque Wrenches, Torque Multipliers, Torque Transducers, Torque Watches, and Torque Readout
-
Product
Calibrators/ Digital Manometers
-
Meriam has earned the reputation as a world leader in the accuracy of our calibrators and digital manometers. We offer excellent hand held performance at a value price. Features include min/max capture, data record, pressure measurement, averaging and timed pressure tests. "Smart" digital manometers are well suited for field measurement and process control.
-
Product
Power and energy calibrators
-
Three or single phase electric power/energy calibrator with power quality functions for calibration and testing of grid measuring appliance like power meters, power transducers or power quality analysers.
-
Product
IEC60068-2-75 Spring Hammer Calibration Device
-
Shenzhen Chuangxin Instruments Co., Ltd.
It is mainly used for the calibration of the spring hammer, which is based on IEC60068-2-75-1997 and GB2423.55-2006 standard design and manufacture, primarily for third-party testing organization, the National immigration department and appliance-related research institutes.
-
Product
Speedometer Calibrator
-
Hypertech’s Speedometer Calibrator can correct the speedometer and odometer for tires up to 54 inches (depending on the application), and/or non-stock rear gear ratios. This new device is engineered for consumers that want the speedometer recalibration functions of the Speedometer Calibrator without the additional expense of the other tuning features. The Speedometer Calibrator comes with a USB cable and a CD containing software to enable quick updates and upgrades over the internet. For an additional charge, the Speedometer Calibrator can be upgraded to a Speedometer Calibrator via the internet to include all the Speedometer Calibrator features available for that vehicle.
-
Product
Speed-O-Calibrator
16470
-
The Speed-O-Calibrator consists of two sections, control box and drive unit. The control box is stored inside the drive unit for easy portability. The control box weighs less than 6 lbs and is used in the cab of a locomotive to control the speed of the Axle Alternator Drive Unit. The Drive Unit drives the Axle Alternator at various speeds while the user verifies that the correct speed is displayed in the cab. The test system provides a complete test of the speedometer system, including all types and paddle lengths of Axle Alternators.
-
Product
Broadly Tunable, Narrow-Linewidth & Automated Laser Source Covering the Visible, Neur Ultraviolet & Near Infrared
SolsTiS Rainbow
-
SolsTiS Rainbow brings together M Squared’s award-winning laser technologies into a single, easy-to-use platform providing hands-free automated access to light of any colour in the visible, near-ultraviolet and near-infrared wavebands. The advanced SolsTiS Rainbow features a fully-automated self-aligning, sealed, high-efficiency SolsTiS, a SolsTiS Doublet SHG cavity and a frequency mixing module, all capable of rapid and precise narrow-linewidth wavelength tuning in the range from 350 – 1100 nm. Furthermore, SolsTiS Rainbow is capable of user-defined high-speed, high-resolution stepped and continuous scanning over extended tuning ranges.
-
Product
Bench Power Supply, Calibrated, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL
-
The 72-2690 CAL from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
Product
Humidity Calibration
-
Trescal provides full Humidity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Humidity Calibration services can be delivered at your site or at our lab. Accreditations for our humidity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.