RF Multiplexers
Devices that select between a number of RF signals.
-
Product
PXI/PXIe MEMS Optical Switch, Dual Insert/Bypass, Single-Mode
40-860A-322-HI
Multiplexer Module
The 40/42-860A-322-HI is a PXI/PXIe dual insert/bypass switch with MU connectors,, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI Quad SPDT RF Switch 6GHz 50 SMA Terminated
40-880-002
RF Switch
A range of 50Ω SPDT RF switching with automatic termination of unused signals. Available as a dual switch in a 1 slot PXI module, a quad switch in a two slot PXI module or hex and octal switches in three slot PXI modules.
-
Product
PXI High Density Multiplexer, 4-Bank, 16-Channel, 1-Pole, Screened
40-610A-014
Multiplexer Module
The 40-610A-014 is a screened 4-bank, 16-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
LXI 8:1 Optical MUX LC Loop-Thru
60-850-421
Multiplexer Module
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
Product
PXIe Microwave Multiplexer, Dual SP6T, 26.5 GHz, 50 Ω, SMA, Terminated, Failsafe
42-785C-532-T
Microwave Multiplexer
The 40-785C-532-T (PXI) and 42-785C-532-T (PXIe) are dual failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI Switched Guard Reed Relay Module, 16x 2:1 Multiplexer
40-121-011
Multiplexer Module
The 40-121-011 provides 16x 2:1 multiplexers in a single slot PXI module and designed to provide an isolation resistance in excess of 1013Ω. It has been designed to ensure high isolation resistance through the use of switched guards, making it ideal for low level measurements and semiconductor test.
-
Product
LXI Microwave Multiplexer, SP6T, 1-Bank, 50GHz, 50Ω, SMA-2.4
60-800-601
Multiplexer Module
Our 60-800-601 is a 1 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
40 Channel Single-Ended Multiplexer Module for 34970A/34972A
34908A
Multiplexer Module
Use the Keysight 34908A module for the 34970A/34972A Data Acquisition/Switch Unit for the greatest density in common-low applications, such as battery test, component characterization, and benchtop testing. Each module switches 40 one-wire inputs. All two-wire internal measurements except current are supported. The module low connection is isolated from earth and can float up to 300 V.
-
Product
RF Sensor for Spectrum Monitoring
N6841A
RF Sensor
Reduce operating costs with affordable spectrum monitoring and TDOA geolocation measurementsDeploy fully capable RF monitoring stations faster with simple hardware and measurement-specific software24/7 real-time remote spectrum monitoring with Signal Surveyor 4D softwareCapture intermittent signals with spectrum analysis softwareFaster search and signal isolation with broad attenuation and wide dynamic rangeLocate narrow or wideband signals with geolocation software
-
Product
PXI Single SP6T Multiplexer 6GHz 50 SMA
40-784A-001
Multiplexer Module
Pickering Interfaces’ range of 40-784A PXI Microwave Multiplexer Modules have a characteristic impedance of 50Ω and are capable of switching signals up to 40GHz. Available in single, dual or triple, SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors
-
Product
PXI 2A Multiplexer, 2-Bank, 4-Channel, 16-Pole
40-614C-014
Multiplexer Module
This 2-bank, 4-channel, 16 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
75 Ohm BNC to MCX Adaptor Assembly
40-978-781-0.5m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Single-Mode
40-850A-414
Multiplexer Module
The 40/42-850A-414 is a PXI/PXIe 4-channel multiplexer with LC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI/PXIe High Density 2A Multiplexer, 1-Bank, 128-Channel, 1-Pole
40-614D-015
Multiplexer Module
The 40-614D-015 (PXI) and 42-614D-015 (PXIe) 1-bank, 128-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
75 Ohm MCX to MCX Cable Assembly
40-977-761-0.1m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
MS-M 3-Pin RF Cable to SMB, 0.5m
40-979-503-0.5m-SMB
RF Cable Assembly
The MS-M RF 3-Pin cable assembly is constructed from RG178 Silver Plated Copper Clad Steel Wire with PVC insulation and an attenuation of 1.08dB/m at 400MHz. Screwlocks are provided to secure the MS-M connector to the associated product.
-
Product
50 Ohm SMB to BNC Adaptor Assembly
40-978-501-0.5m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 18 GHz, 50 Ω, SMA, Terminated, Failsafe
42-785C-522-T
Multiplexer Module
The 40-785C-522-T (PXI) and 42-785C-522-T (PXIe) are dual failsafe SP6T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP4T, 40 GHz, 50 Ω, SMA-2.9, Remote Mount, Failsafe
42-785C-443-E
Multiplexer Module
The 40-785C-443-E (PXI) and 42-785C-443-E (PXIe) are triple failsafe SP4T 40 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI High Density Mux 5 Channel 16 Pole
40-670A-021-5/16
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected.In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 18 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-785C-523-E
Multiplexer Module
The 40-785C-523-E (PXI) and 42-785C-523-E (PXIe) are triple failsafe SP6T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI 3A Power MUX BRIC, 4-Channel, 48-Pole
40-571-004
Multiplexer Module
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXIe Microwave Multiplexer, Single SP4T, 26.5 GHz, 50 Ω, SMA, Failsafe
42-784B-131
Microwave Multiplexer
The 40-784B-131 (PXI) and 42-784B-131 (PXIe) are single failsafe SP4T 26.5 GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe High Voltage Multiplexer, Hex 7-Channel, 2-Pole
40-321-123-HI
Multiplexer Module
The 40-321-123-HI (PXI) and 42-321-123-HI (PXIe) are hex 7-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PXI Solid State Multiplexer, Dual 3-Channel, 30 Amp
40-667B-011
Multiplexer Module
The 40-667B-011 is a dual 3-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
Product
PXI 3A Power MUX BRIC, 24-Channel, 12-Pole
40-571-306
Multiplexer Module
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP12T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-788-222-TE
Multiplexer Module
The 40-788-222-TE (PXI) and 42-788-222-TE (PXIe) are dual failsafe SP12T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 50/125 Fiber, SC/PC Connectors, With Interlock
42-850A-214-M50-HI
Multiplexer Module
The 40/42-850A-214-M50-HI is a PXI/PXIe 4-channel multiplexer with SC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI/PXIe MEMS Optical Switch, Single Insert/Bypass
40-860A-212
Multiplexer Module
The 40/42-860A-212 is a PXI/PXIe single insert/bypass switch with SC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI 5A MUX, 2-Bank, 24-Chan, Ind. Isolation
40-651-102
Multiplexer Module
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.