Test Call Generators
check telecom networks by call event validation.
-
Product
P5160 Pylon Probe
P5160
-
Current Rating (Amps): 8Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,310Overall Length (mm): 33.27
-
Product
Memory Test System
T5230
-
T5230 memory test system for NAND/NVM devices adopts a combined array architecture to achieve best-in-class cost-of-test performance for wafer test, including wafer-level burn-in (WLBI) and built-in self-test (BIST). The system can perform on-wafer test of 1,024 memory devices per test head in parallel, delivering high productivity and enabling floor space savings of up to 86%. Multiple test cells are connected per system controller in the T5230, allowing independent wafer test of each test cell. The test cells can be stored in a general multi-wafer prober while minimizing the test cell floor space, and the tester can be docked with probers in both linear and multi-stack configurations. For functional tests at a maximum test rate of 125MHz/250Mbps, the T5230 assures high timing accuracy, repeatability, and failure detection capability.
-
Product
Dual/Quad 125 MS/s VXI Arbitrary Waveform Generator
3164
-
The Racal Instruments™ 3164 Series is a single-wide VXIbus Module. The 3164-2 has two 14-bit Arbitrary Waveform Generator (AWG) channels that operate independently, and the 3164-4 AWG has four channels. The maximumsample rate for each channel is 125 MS/s. All waveforms can be sampled from data previously loaded into waveform memory or loaded and output on the fly.
-
Product
Test Handler
M6242
-
Optimal Test Handler for Mass-Production DRAM, with Double the Throughput.
-
Product
PXIe Microwave Signal Generator
LSX2091X
-
The LSX2091X is a 20GHz Single Channel PXIe Microwave Signal Generator that offers industry leading performance, in a modern modular 2 slot PXIe format that can be used on the desk, embeded in a system or or easily scaled up to multiple channels ATE systems.
-
Product
1.25GS/s 16Bit 1GS Mem 8CH Arbitrary Waveform Generators
P1288B
-
The Proteus P1288B, is a 1.25GS/s, eight channel arbitrary waveform generator packaged in a 4U, 19” standalone box with a 9” touch screen and on board PC , offering technologically advanced options and configurations that integrate the ability to transmit, receive and perform digital signal processing all in a single instrument. The P1288B offers industry leading performance Including an innovative task oriented programming, real time data streaming, fast feedback loop for environment dependent waveform generation and user customizable FPGA for application specific solutions.
-
Product
Scienlab Battery Test System — Cell Level
SL1002A
-
Test System with up to 36 Channels.The Keysight SL1002A provides sink and source with 0 to 6 V, 100 to 600 A, 0.6 to 3.6 kW and 36 channels for battery cells.
-
Product
40GHz Single Channel MW Signal Generator 19" 1U Rack
LSX4091R
-
The LSX4091R is a 40GHz Single Channel Microwave Signal Generator, offers industry leading performance, in a 1U, 19” rack-mounted box. It features exceptionally fast switching speed, superior signal integrity and purity and all the necessary modulated signals for analog communication systems. The design offers excellent performance and abilities combined with an affordable price tag, needed from the R&D benches to the production lines.
-
Product
PCIe 2.0 Test Platform
PXP-100B
-
The Teledyne LeCroy PXP-100B Test Platform provides a convenient means for testing PCIe 2.0 add-in cards with a self-contained portable and powered passive backplane. The PXP-100B provides power required for both cards under test, and an interposer can be used for connection to a protocol analyzer. As an alternative to an interposer, the PXP-100B includes two mid-bus probe footprints to allow connection to an analyzer via a mid-bus probe.
-
Product
VXG Vector Signal Generator
M9484C
-
The M9484C VXG is the industry’s first dual-channel vector signal generator capable of generating signals up to 54 GHz with 2.5 GHz of modulation bandwidth per channel. The VXG vector signal generator helps you deliver the next frontier of wireless technology such as 5G and satellite communications with a fully integrated, calibrated, and synchronized solution.
-
Product
Wireless Device Functional Test Reference Solution
-
The Keysight S8890A Wireless Device Functional Test Reference Solution provides an automation environment which is both simple to use, yet comprehensive and powerful. Based on the Test Automation Platform www.keysight.com/find/TAP, S8890A provides optional instrument driver/plug-ins offering simplified logically grouped control steps. These steps can be sequenced, looped and swept to provide powerful individual test cases or comprehensive sequences. Each driver/plug-in is provided with extensive starter sample test cases which can be modified by Keysight or the end user the UE to be tested. Plug-in options:
-
Product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2A-2
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 0.70 (20.00) - 1.30 (37.00) Non Replaceable General Purpose Probe
A-S-C
-
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1W1S
-
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C40
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35 Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-10
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Alternate 1.30 (37.00) - 4.50 (128.00) General Purpose Probe
HPA-1A-1
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
In-Circuit Test
TestStation LH
-
The TestStation LH in-circuit test system is a lower-cost, small footprint, feature scalable version of Teradyne's popular, award winning TestStation product family. TestStation LH features SafeTest protection technologies for accurate, reliable, and safe testing of the latest low-voltage technologies.
-
Product
OTP-Based Test System
-
Power electronics assemblies often cannot be tested using conventional technology for their electrical performance. Due to the adaptability of the instrumentation, the OTP concept offers an ideal platform even beyond the space requirements of several control cabinets. In order to achieve high test flexibility with different assemblies, the system was equipped with three-phase AC sources and AC loads as well as a precise three-phase power meter. DC sources and loads with different current and voltage ranges cover the test of frequent DUT operating parameters. Time-dependent voltage or current signals can be stimulated by an arbitrary generator with power amplifier. General measurements such as current, voltage, frequency, resistance can be carried out flexibly at various test points using the matrix concept. An oscilloscope with RF multiplexer is available for high-frequency measurements such as residual ripple, switching processes, etc.
-
Product
1.25GS/s 16Bit 1GS Mem 4CH 4 Markers AWG
P1284D
-
The Proteus P1284D, is a 1.25GS/s, four channel arbitrary waveform generator packaged in a 4U, half 19” dedicated chassis, offering technologically advanced options and configurations that integrate the ability to transmit, receive and perform digital signal processing all in a single instrument. The P1284D offers industry leading performance Including an innovative task oriented programming, real time data streaming, fast feedback loop for environment dependent waveform generation and user customizable FPGA for application specific solutions.
-
Product
Standard 1.00 (28.00) - 2.30 (65.00) Non Replaceable General Purpose Probe
P2532-1
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 156Test Center (mm): 3.96Full Travel (mil): 139Full Travel (mm): 3.53Recommended Travel (mil): 93Recommended Travel (mm): 2.36Overall Length (mil): 812Overall Length (mm): 20.62Rec. Mounting Hole Size (mil): 94.5Rec. Mounting Hole Size (mm): 2.40Recommended Drill Size: #41 or 2.40 mm
-
Product
Modular Functional Testing Platform
OTP2
-
Functional testing is an important part of product development and manufacturing and is used to ensure quality, performance and reliability from launch to end of life. A modern, future-proof functional test system must meet many criteria in order to meet the ever-growing demands of the industry. The OTP 2 open test platform developed by LXinstruments meets the following requirements for a dynamic and highly competitive market.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2F
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
EXG X-Series RF Analog Signal Generator, 9 kHz to 6 GHz
N5171B
-
Achieve faster throughput and greater uptime with the cost-effective performance optimized for manufacturing testPerform basic parametric testing of components and functional verification of receivers with industry-leading output powerThoroughly verify receiver performance by simulating complex analog modulation scenarios with multi-function generator capabilityMinimize downtime and expenses with self-maintenance solutions and low-cost repairs
-
Product
EV-DO Analysis Using NI PXI RF Test Instruments
NI-RFmx EV-DO
-
Highly optimized RF measurement experiencePerform physical layer analysis on EV-DO cellular signals including MODACC, ACPR, CHP, OBW, and SEMSimple access to advanced measurement parallelism
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1L
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5H
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Alternate 2.52 (71.00) - 6.50 (184.00) General Purpose Probe
EPA-3L5-1
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-1
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
PXIe Precision AWG: 4 Channels, 400 MHz
M5301A
-
The M5301A is a single-slot PXIe module with four baseband AWG outputs, clock input and output, and four triggers. It provides high performance with easy-to-use programming libraries, real-time sequencing technology, and FPGA programming.





























