Breaker Locators
match a circuit to a breaker.
-
Product
Breaker Testing Software
BTS11
-
To test circuit breakers in general, is to operate the breaker and check the contact timing. However in factory testing and during field service/maintenance some other tests are necessary. For field testing these other tests can also be very useful in diagnostics purpose.
-
Product
HANDHELD “RADIO LOCATOR” PROBE
TS-8
-
Easy to operateUnaffected by surface coverLight WeightTelescoping handleRugged ConstructionWater resistantDepth locator "Bubble"
-
Product
Circuit Breaker Test System
AutoScan
-
AutoScan Circuit Breaker Test System is used for performing routine tests on circuit breakers and various other types of switchgear. This test system is designed to test vacuum circuit breakers, high voltage circuit breakers, and extra high voltage circuit breakers as per suitable standards.
-
Product
Hazardous Location Syringe Pump
500HLf
-
The Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.
-
Product
Visual Fault Locator
TM191
-
TM191 series visual fault locator is used for the measurement in single mode or multi-mode fibers. It features a rugged design, a universal connectorand an accurate measurement
-
Product
Earth Leakage Breaker And Residual Current Device
IGR Series
-
IGR Leakage Current Analyzer is invented as the world first, and also can measure Insulation Resistance (MO) without power cut-off. This patented instrument can analyze leakage current, and display Igr(resistive), Igc(capacitive), and Io(vector sum), Ground Insulation Resistance, and the phase angle between voltage and current. (IGR ELB) - Operates due to Igr. - Properly-operating in spite of IGC in digital era. ( Not tripping on UPS load and Harmonics and noise area) - Possible to go down Igr for safety of people and animals. - Possible to manufacture high sensitive ELB. - Possible to prevent fire from electric leakage current.
-
Product
Circuit Breaker Timer
-
* Micro - Controller based technology* Very Compact and lightweight* Very accurate measurements* Available with built - in thermal printer or RS 232 interface* Available in bench top and industrial suit case models.* Economical
-
Product
Water Pipe Locator & Leak Detector
RD510
-
Water leakage is a major global challenge. Water pipe leaks lead to substantial water loss, increased operational costs, and undermine efforts to ensure sustainable water management and supply.
-
Product
Automatic Circuit Breaker Timer Kit With Printer
-
NMC OFFERS FULLY AUTOMATIC CIRCUIT BREAKER TIMER KIT WITH IN BUILT PRINTER AND COMPUTER INTERFACE.
-
Product
Leak Locator
XL-2
-
Lightweight & Strong11 Position filter to pinpoint leak and remove background sounds2 Sensitivity controlsSuper Sensitive magnetic transducerHigh gain, 4-stage amplifierVisual and Audible indicationsCoarse and Fine SensitivityExtremely sensitive pickup with removable 7" (177.8mm) probeBattery operated and with battery condition indicator
-
Product
Measuring Display Unit Breakers
-
Mitsubishi Electric Automation, Inc
Measuring display units (MDU) are integrated with molded-case circuit breakers and earth leakage circuit breakers for measuring, displaying, and transmitting information on cable ways. This display unit closely monitors energy consumption by measuring current, voltage, power, electric energy, harmonic current, leakage current and power factor.
-
Product
Cable Sheath Fault Location
-
Locating cable sheath faults is one of the last steps in cable testing, occurring after you have identified the existence of a cable fault via the identification procedure based on your specific site variables and the type of system you are working on
-
Product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
-
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
Product
Circuit Breaker Contact Resistance Meters
-
Vanguard Instruments Company, Inc.
The Vanguard Auto-Ohm 10 is a 10-ampere battery powered micro-ohmmeter designed for low-resistance-measuring applications such as the measurement of resistance in circuit breaker contacts, bushing contact joints, and welding joints. The unit is powered by four 3400mAh, 3.7Vdc Li-Ion rechargeable batteries. With these high capacity batteries, up to 2,900 tests per charge (10A/2 second duration) can be performed in the field.
-
Product
Mobile Cable Fault Location System
Syscompact 2000
-
Fault location with Syscompact 2000. The Syscompact 2000 is a multifunctional cable fault location system designed for modular 19" rack technology. The integrated surge and test generator is used for cable and sheath testing as well as for precise location of high-resistive and intermittent faults. The SYSCOMPACT 2000 is preferably used in low- and medium-voltage networks for fault location up to a cable lengths of 65 km. * Fast and reliable * Precise, dependable cable fault location High performance * high voltage unit* Integrated proven cable fault pre-location methods
-
Product
HV High Performance Circuit Breaker Analyzer
CBV-32
-
We conceived the CBV-32 to provide the best range of testing for electrical facilities such as circuit breakers (using gaz, oil, air, vacuum…) or synchronous condensers all the way up to 800kV and more. It combines Timing, Motion Dynamic Resistance Measurements, and Vibration, all in a single test.
-
Product
Open Circuit Locator
A994
-
The A994 is an open circuit locator for electric and telephone cables wind on the reel; it gives the position of the fault from the inside or outside end of the cable, in percentage to the total cable length. The instrument measures the ratio of the capacitances of the two sections of failed conductor using two high precision i/v converters. The advantage of this method is due to the fact that the measurement error depends almost exclusively on the dimensional inhomogeneity of the cable. The A994 has the unique feature to permit the location of fault in cables with all broken wires. This instrument locates breaks in cables with a total capacity between 2 nF and 5 uF. The distance to fault is displayed on a large LCD display.
-
Product
Visual Fault Locator
-
OrienTek Optical Technology Ltd.
powerful, mini visual laser source for fiber fault locating. It has attractive design and small size and it is easy to operate. ● Bright red laser at 650nm● Pulsed and CW operation● Outpower: 1mw,10mw,20mw,30mw● 2.5mm universal connector● 40 hours of operation(1mW)● Pocket size design● 1.25 mm adapter for LC (optional)
-
Product
Cable Fault Location System
BAUR Syscompact 2000 Portable
-
Cable fault location system Syscompact 2000 portable. The cable fault location system Syscompact 2000 portable is used for precise location of high-resistance and intermittent faults in low and medium voltage cables.* Fast and reliable* Precise, dependable cable fault location* High performance high voltage unit* Integrated proven cable fault pre-location methods
-
Product
Sonde Locator
vLoc3-Cam
-
The vLoc3-Cam is the easiest to use sonde locator on the market today. The omni-directional antenna array allows for approaching the sonde from any position. The directional arrows will guide the user first to the front or rear locate point and then directly to the sondes position. The vLoc3-Cam includes multiple sonde frequencies making it compatible with the major push cameras and crawler cameras on the market. The Pushrod Trace mode shows a second display geared for tracing the path of the pushrod deployed in the pipe or tracing pipes with an optional portable transmitter.
-
Product
Circuit Breaker Test System
TDR900
-
It operates and records a circuit breaker’s contact timing, motion, velocity, main contact engagement & synchronization, trip and close coil initiation and currents.
-
Product
Cable Fault Location System
Syscompact 2000 M Pro
-
Cable fault location system 2000 M pro. The portable BAUR Syscompact 2000 M pro cable fault location system is used for cable fault location and cable testing in low- and medium-voltage cables up to 65 km length.* Fully integrated proven cable fault pre-location methods* Surge mode for acoustic pin-pointing* Easily transportable* Ideal for locations that are difficult to access
-
Product
Tool, Crimp, QuadraPaddle And TriPaddle, Receiver And ITA, Locator Required
910101103
Crimp Tool
Tool, Crimp, QuadraPaddle and TriPaddle, Receiver and ITA, Locator Required
-
Product
Fault Locator
TRANSFLEKT
-
TRANSFLEKT simplifies the location of transient faults on the low voltage distribution network.
-
Product
Cable Fault Locator
TX2002
-
Lowest Cost Full Specification Professional Graphical TDR Rugged Palm Top Design 350g (12oz) 5 Measurement Ranges up to 3500m (11,500ft) 50, 75 & 100 ohm Selectable Cable Impedance Built in Tone Generator for Pair Tracing & Identification Suitable for testing all Communications Cables Water & Dust Proof to IP54 Complete with tool-belt holster & test leads
-
Product
Digital Circuit Breaker Analyzer
CT-3500 S2
-
The CT-3500 S2 is Vanguard’s second generation, stand-alone, digital, microprocessor-controlled, circuit-breaker timer. It measures the elapsed time from the instant a breaker coil is energized to the instant of opening or closing of a circuit-breaker’s dry contacts. In addition to timing a breaker’s contact response time, the CT-3500 S2 can also time relays or other switching functions that use an initiating trigger voltage (24-300 Volts DC or AC). The timer-triggering voltage starts three independent electronic timers. Each timer is individually stopped by its respective dry-contact closing or opening. The CT-3500 can fully analyze the timing of all circuit breaker operations (Open, Close, Open – Close, and Close – Open). Timing results are displayed in milli-seconds and cycles on the unit’s back-lit LCD screen and can be printed on the built-in 2.5-inch wide thermal printer.
-
Product
Circuit Breaker Testing Equipment (SCOT Series)
SCOT M3K+
-
SCOT M3K+ measures and displays CLOSE, OPEN and CLOSE-OPEN times of Main contacts of 3 poles connected end to end, simultaneously. Ideally suitable for CBs with single break per pole.
-
Product
Circuit Breaker Time Interval Meter
-
Measuring contact timings is useful for finding the contact bounces and non-simultaneity of contacts. This helps in finding the possible electrical or mechanical defects in the circuit breaker contacts. Timing analysis also make it possible to detect incorrect mechanical adjustments and wear phenomena of the circuit breaker by measuring the differences between the fastest and slowest phases.
-
Product
Circuit Breaker Analyzers & Timers
CAT Handheld Series
-
When it’s not practical to use conventional robust circuit breaker analyzers, a handheld circuit breaker analyzer and timer may come handy. DV Power has developed a unique CAT Handheld series. It is specially designed for testing of circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium and high-voltage substations or in industrial environments.CAT Handheld series consists of two models, CAT-P and CAT-H. Both of them have a large (5,7 in) colored touch screen display. Because of that, test results are visible in dark places as well as in bright sunlight.Powerful internal Li-Ion battery of the instruments can last up to 8 hours of testing without recharging.CAT Handheld series records:main contacts operating times,contact synchronization,sequence time,a resistance of pre-insertion resistors,open and close coil currents,main contacts bounce time,auxiliary contact time,DC Voltage.Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering signal from current clamps connected to circuit breaker coil.CAT-H is capable of performing a coil control, while this feature is optional at CAT-P instrument. In contrast to CAT-H, CAT-P instrument can execute “First Trip” test.Both instruments display numerical and graphical results. Because of that, a user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects.A user can download test results to a PC via Bluetooth interface for more detailed analysis using DV Win software.





























