Product
PXI RTD Simulator Module 6-Channel PT1000
40-262-102
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
In-Head RTD Temperature Transmitter
SEM203/P
-
The RTD in-head mounted temperature transmitter connects to any standard pt100 resistance sensor and converts the linearised temperature to a (4 to 20) mA signal.
-
Product
4 2/3 Digital Temperature (RTD) Meter
CS2-T
-
CS2-T Temperature Indicator has been designed with high accuracy measurement, display and communication of Thermocouple or Pt100Ω.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments application.
-
Product
PXI RTD Simulator Module, 4 Channel, PT500
40-263-502
Simulator
The 40-263-502 is a 4-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
4-Ch RTD Input EtherCAT Slice IO Module
AMAX-5015
-
RTD InputChannels : 4Input Connections : 2 or 3 wireResolution : 16 bit with ±0.1% FSR accuracySample Rate: 100 sample/s (per channel)Burn-out detection: Yes
-
Product
PXI RTD Simulator Module, 12 Channel, PT100
40-263-301
Simulator
The 40-263-301 is a 12-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
Thermocouple & RTD Termometers
-
Amprobe thermocouple thermometers give you a professional way to measure, monitor and log temperature. Eight models let you choose the accuracy and feature set you need. For superior accuracy and stability in a process environment, choose an Amprobe RTD thermometer.
-
Product
Dual Relay Trip Amplifier for RTD and Slidewire Sensors
SEM1633
-
The SEM1633 provides an accurate alarm / switching function when used with RTD or Slidewire sensors. Other sensor characteristics or your own 22 point linearization characteristic (for slidewire or linear resistance) can be downloaded into the product enabling you to adapt it exactly to your application.
-
Product
Isolated RTD Input Module
ADAM-3013
-
1000 VDC 3-way optical isolationBuilt-in microprocessorSwitch configurable for 0~5 V, 0~10 V or 0~20 mA outputsSwitch configurable Pt and Ni RTD input ranges
-
Product
16-Channel RTD Signal Conditioning Card
ProDAQ 5821
-
The ProDAQ 5821 series of Signal Conditioning Cards is designed to interface with a variety of sensors, principally RTDs, Thermistors, Cryogenic Diodes and Voltage type sensors. Each version of the 5821 provides the capability of precise 4-wire measurement. In order to achieve this, a precise 500μA constant current source is provided per channel. The current source can be disabled on a per channel basis and is monitored to ensure that current is flowing. The value of the output current is stored on-board after calibration. In order to achieve the highest accuracy the output current may be automatically calibrated 'on-the-fly' using the ProDAQ 3416 24-bit Sigma-Delta ADC card and an on-board precision resistor.
-
Product
RTD Measurement for VMEbus
VME390
-
The VME390 features 24 two, three or four wire high-accuracy PT100 measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued.
-
Product
PXI RTD Simulator Module, 4 Channel, PT100
40-263-501
Simulator
The 40-263-501 is a 4-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module, 8 Channel, PT100
40-263-401
Simulator
The 40-263-401 is an 8-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module 6-Channel PT100
40-262-101
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
RTD Thermometers
-
Automatic, positive implied, negative polarityindication.Low battery indication: The “ ” is displayed when thebattery voltage drops below the operating level.Measurement rate: 1 times/second.Operating environment: 0°C to 50°C at<70% R.H.Storage temperature: -20°C to 60°C, 0 to 80% R.H. withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% R.H.Battery: 1.5Vx4pcs AAA size.Dimensions: 160mm(H) x 83mm(W) x 38mm(D).Weight: approx. 255g including batteries.
-
Product
PXI RTD Simulator Module, 4 Channel, PT1000
40-263-503
Simulator
The 40-263-503 is a 4-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module 12 Channel PT100
40-262-201
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
Product
Wireless Precision RTD Based Temperature Data Logger with LCD
RFRTDTemp2000A
-
The RFRTDTemp2000A is an RTD-based, wireless temperature data logger with display. This data logger is ideal for applications that require high accuracy temperature monitoring such as within laboratories, pharmaceutical and biotech industries. The RFRTDTemp2000A accepts 2, 3 or 4 wire 100Ω platinum RTD’s and features a device accuracy of +/-0.5°C.
-
Product
3-CH RTD Input Module
ND-6013
Data Acquisition Module
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Product
RTD Measurement for CompactPCI
CPCI390
-
The CPCI390 has a 3U form factor and features six 2-, 3-, or 4-wire high-accuracy RTD measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued. The local DSP (TMS320C203) performs linearization, auto-calibration and alarm limit checking. Sensordata is available in °C, °F, K and Ohm. All inputs are optically isolated from the system.
-
Product
Strain Gauge and RTD via Ethernet
2612
-
Simultaneous measurement of four strain gauges or RTDs6 or 4-wire measurement with 200 nV resolution at a 6 Hz rateAuto-calibration cycle measures excitation at remote strain gaugeCompatible with Linux and WindowsUse our design assistant to configure a system and calculate pricing
-
Product
PXI RTD Simulator Module 12-Channel PT1000
40-262-202
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
RTD Alarm Setter Transmitter
Model TAR
-
Kusam Electrical Industries Limited
• 4 Digits Display For Input Signal:100.0 - 400.0 • Display - 100~400 °C / 100~700 °F • Output Signals Are Programmable. • Ultra-thin Dimension, 27mm width. • Non-Combustible PC Case .DIN Rail or Wall Mounting. • High Dielectric Strength ( AC 2KV / Min , Input / Output / Power )
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Suitable For RTD Sensors Approved To ATEX And IECEx Standards
TTR200X -
-
The TTR200X is our mid range transmitter for RTD or Slidewire sensors approved to ATEX and IECEx standards. It can accept many different types of RTD sensor such as Pt100, 500, 1000 etc and slidewire sensors up to 100K Ohm
-
Product
PXI RTD Simulator Module, 24 Channel, PT1000
40-263-003
Simulator
The 40-263-003 is a 24-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
785189-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
PXI RTD Simulator Module, 20 Channel, PT100
40-263-101
Simulator
The 40-263-101 is a 20-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.