Coaxial Matrix
route radio frequency signals through a a grid array.
-
Product
PXI 2 Slot BRIC 132x4 2-pole (3 sub-cards)
40-562A-222-132X4
-
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays.
-
Product
LXI Triple 75x4 2-Pole HV Matrix
60-311-003
-
The 60-311 is a 2-pole Matrix Module available with one, two or three separate 75x4 matrices housed in the same case. It is capable of cold switching 750VDC continuous with a carry current of 2A plus higher pulse conditions e.g. typically 1000VDC for 1s with low duty cycle or 6A for 200us with <1% Duty Cycle.
-
Product
PXI Single 44x4 Matrix, 2 Pole Switching
40-523-022
-
Medium density PXI dual 44x4, 2-pole matrix - it is also available in reed relay formats of 1-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
Product
PXI 8-Slot BRIC Matrix, 440x4 1-Pole (10 sub-cards)
40-562B-121-440X4
-
The 40-562B-121-440X4 is a high density BRIC8 matrix module with a size of 440x4 with 1-pole switching. It is part of a range of BRIC matrices available in 2, 4, 8 or 12-slot formats to suit high performance PXI matrix requirements and is constructed using instrumentation quality reed relays.
-
Product
PXI 16x4 Matrix Module, 2-Pole 2A,60W
40-517-002
-
The 40-515/516/517 2 Amp, 2-Pole Matrix Modules form part of the System 40 PXI ProgrammableSwitching system. Each module consists of a matrix of 64 2-pole electro-mechanicalrelays under the control of a PXI/PCI interface.These modules are designed for switching medium voltage/power signals in test applicationswhere reed relays do not have sufficient rating. They are also suitable for telecomsapplications where send and return signals need to be switched simultaneously.
-
Product
PXI 8 Slot BRIC 99x16 2-pole (9 sub-cards)
40-562A-122-99X16
-
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
LXI High Density 40x64 2A Matrix
60-552-004
-
A high-density single pole LXI matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
Product
PXI 8 Slot BRIC 120x16 2-pole (8 sub-cards)
40-561A-122-120X16
-
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
LXI Scalable Matrix - 2Amp 10x25 Configurable Matrix Plugin Module
65-219-207
-
The 65-219-207 is a 10x25 plug-in module and is part of a scalable matrix platform designed to provide a large matrix solution with 2A current carrying capacity on all Y paths.
-
Product
LXI High Density 256x16 2A Matrix
60-554-008
-
A high-density single pole matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
Product
Single 16x16 1-Pole High-Density PXI Matrix Module
40-520-001
-
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
LXI Scalable Matrix - 2Amp 10x20 Configurable Matrix Plugin Module
65-219-206
-
Matrices are created by populating the 65-200 scalable matrix chassis with plug-in modules that provide access to the X axis on 15-pin D-type connectors and the Y axis on 50-pin D-type connectors. The chassis is capable of supporting matrices with a Y axis size of 20 or 40 and X axis sizes up to 60 in increments of 10. Users can specify as many or as few plugin modules as they require and can field upgrade the chassis to extend the matrix size.
-
Product
PXI 4-slot BRIC Matrix, 126x12, 1 pole (3 Sub-cards)
40-558-401-126x12
-
The 40-558-401-126x12 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
Product
PXI/PXIe RF Matrix, Dual 2x2, 2.5GHz, 50Ω, MCX
40-877A-102
-
The 40-877A-102 (PXI) and 42-877A-102 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
LXI Microwave Matrix
60-891-006
-
The 60-891-006 is a compact 50 Ω microwave switching matrix with added loop-back functionallity and a maximum bandwidth of 18 GHz. It is ideal for constructing complex microwave switching systems for many applications.
-
Product
PXI/PXIe RF Matrix, Single 4x4, Terminated, 8GHz, 50Ω, SMA
42-884B-001
-
The 40-884B-001 (PXI) and 42-884B-001 (PXIe) are 4x4 solid state RF matrices with a bandwidth of 8GHz and power handling to +30dBm. The module supports up to 4 simultaneous point to point connections across the matrix.
-
Product
MCX Male to SMA Male Cable, 50 Ohm, 1 m
188377-01
-
The MCX-SMA Coaxial Cable, sometimes referred to as MCX400 or MCX410, connects measurement and signal devices. NI offers this 50 ohm cable in different lengths.
-
Product
PXI 4-Slot BRIC Matrix, 132x8 1-Pole (6 sub-cards)
40-562B-021-132X8
-
The 40-562B-021-132X8 is a high density BRIC4 matrix module with a size of 132x8 with 1-pole switching. It is part of a range of BRIC matrices available in 2, 4, 8 or 12-slot formats to suit high performance PXI matrix requirements and is constructed using instrumentation quality reed relays.
-
Product
PXI 4-slot BRIC Matrix, 96x16, 1 pole (3 Sub-cards)
40-558-401-96x16
-
The 40-558-401-96x16 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
Product
PXI 4 Slot BRIC Matrix, Solid State, 160x8, 1-Pole (5 sub-cards)
40-563B-021-160X8
-
The 40-563B-021-160x8 is an ultra high density 4-slot matrix module with 1-pole switching and is part of our range PXI BRIC matrices. They are available in 2, 4 or 8-slot sizes to suit high performance PXI switching requirements and are constructed using solid state switches.
-
Product
PXI 2 Slot BRIC Solid State 96x8 1-Pole (3 sub-cards)
40-563A-221-96X8
-
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance PXI matrix requirements and are constructed using solid-state switches. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 8-Slot BRIC Matrix, 528x4 1-Pole (12 sub-cards)
40-562B-121-528X4
-
The 40-562B-121-528X4 is a high density BRIC8 matrix module with a size of 528x4 with 1-pole switching. It is part of a range of BRIC matrices available in 2, 4, 8 or 12-slot formats to suit high performance PXI matrix requirements and is constructed using instrumentation quality reed relays.
-
Product
Dual 16x6 1-Pole High-Density PXI Matrix Module
40-520-303
-
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
LXI High Density 512x8 Matrix with BIRST
60-550-028
-
High-density single pole matrix module capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
Product
4-Slot BRIC, 128x8, 1 Pole, PXI Matrix (2 Sub-cards)
40-559-401-128x8
-
This range of BRIC ultra-high-density large PXI matrices are available in 2, 4 or 8-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
Product
LXI EMR Low Thermal EMF Matrix 42x33
60-511-002
-
This high density 1-pole matrix has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix.
-
Product
SWB-2813, 4x21, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-13
-
4x21, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2813 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
Product
PXI 8-Slot BRIC Matrix, 44x16 1-Pole (4 sub-cards)
40-562B-121-44X16
-
The 40-562B-121-44X16 is a high density BRIC8 matrix module with a size of 44x16 with 1-pole switching. It is part of a range of BRIC matrices available in 2, 4, 8 or 12-slot formats to suit high performance PXI matrix requirements and is constructed using instrumentation quality reed relays.
-
Product
PXI 4-slot BRIC Matrix, 168x6, 1 Pole (2 Sub-cards)
40-558-401-168x6
-
The 40-558-401-168x6 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
Product
PXI BRIC8 HD FIBO Matrix 186x8 2pin brkout
40-592-121-186X8-2P
-
The 40-592 FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC™ format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short-circuits to ground or battery, or short-circuits between input/output lines.