Current Calibrators
An accurate current units of measure to facilitate comparison to and adjustment of instruments.
-
Product
Precision Programmable DC Voltage Calibrator
2701C
-
Designed for critical calibration lab requirements, this 4th generation contemporary 2701C design is lightweight, rugged, and at home on the production line or the engineer’s workstation.
-
Product
Multiport Calibrated Measurements With Switch Instruments
S97553B
-
This application provides a macro which enables full multiport error correction and measurement capabilities using external switch instruments
-
Product
Current Measurements Of PWM Or Inverter, AC/DC 10~200A, Φ24mm
CTF-200DC-U48V
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 10~200A*Current measurements for PWM or inverter
-
Product
Inductive Sensors (eddy Current)
eddyNCDT
-
Inductive sensors from Micro-Epsilon are based on the eddy current principle and designed for non-contact measurement of displacement, distance, position, oscillation and vibrations. They are particularly suitable when high precision is required in harsh industrial environments (pressure, dirt, temperature). Inductive sensors from Micro-Epsilon offer extremely precise measurements where sub-micron accuracy is required.
-
Product
Calibration Kits
-
Atec’s Portable Calibration Kit, PN AHT63506-1, is used to calibrate instrumentation and transducers in engine test cells, as required per T.O. 33K6-4-3416-1 or Atec Technical Manuals.
-
Product
Current Probes | Current Sensors
-
Sensitivity of Conventional Probes Deliver Precise Measurement of Low Current Waveforms from 1 mA. High-precision Current Sensors, DC to 4 MHz, DC to 20 kHz, up to 50 kHz and load current sensors,
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 3-Channel, 4-Pole
42-514-101
Multiplexer Module
The 40-514-101 (PXI) and 42-514-101 (PXIe) are low density multiplexers in dual 3-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Calibration Segment Arm
-
A torque analyzer or a torque sensor are a finely tuned instrument designed for testing and monitoring torque applications. In order to maintain accuracy, it is crucial that torque measuring equipment be properly calibrated regularly. Segment arm is engineered for calibrating torque analyzers and sensors and ensuring instruments are traceable to National or International Standards, such as N.I.S.T and ISO.
-
Product
IEC60068-2-75 Spring Hammer Calibration Device
-
Shenzhen Chuangxin Instruments Co., Ltd.
It is mainly used for the calibration of the spring hammer, which is based on IEC60068-2-75-1997 and GB2423.55-2006 standard design and manufacture, primarily for third-party testing organization, the National immigration department and appliance-related research institutes.
-
Product
Bench Digital Multimeter, Calibrated, 1 kV, 10 A, 3.8 Digit
72-1015 CAL
-
The 72-1015 CAL from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Quad 3-Channel, 2-Pole
40-514-103
Multiplexer Module
The 40-514-103 (PXI) and 42-514-103 (PXIe) are low density multiplexers in quad 3-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 6-Channel, 2-Pole
42-514-104
Multiplexer Module
The 40-514-104 (PXI) and 42-514-104 (PXIe) are low density multiplexers in dual 6-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Capacitor Leakage Current Meter
DU2316/2317
-
Delta United Instrument Co., Ltd.
Leackage Current range display: 0.0001uA ~ 20.00mAAutomatic or Manual trigger with CHARGE/TEST/DISCHARGE100 sets of memory, can be saved test parameter and comparator setting, easy to use.Cover up free, system firmware upgrade can be update via RS-232, easy to maintenanceHi / Lo current limit setting & PASS/FAIL judgment240*64 Graphic LCD display, can be read the reading clearly and easier.User friendly programmable interface, easy to useProvided RS-232C and Handler combinatorial interface option, to meet your needed
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 3-Channel, 4-Pole
40-514-101
Multiplexer Module
The 40-514-101 (PXI) and 42-514-101 (PXIe) are low density multiplexers in dual 3-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Current Measurements of PWM or Inverter, AC/DC 10~200A, φ24mm
CTF-200DC
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 10~200A*Current measurements for PWM or inverter
-
Product
High DC Primary Current Injection Test Set
PDC15k
-
PDC15k High DC Primary Current Injection Test Set adopts high-frequency invert principle to realize the high DC current output capability, with very small size and light weight. PDC15k is modular designed with changeable modules and multi-functions local control software.
-
Product
Integrated Current Sensors
FHS Series
-
*Standard package and small footprint*Cost effective*Standard SOIC 8 surface mount PCB
-
Product
Multiport Electronic Calibration Module (ECal), DC To 20, 6-ports
N7564A
-
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 20 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
30A, 100MHz High Sensitivity Current Probe
CP031A
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Digital Light Meter, Calibrated
93-172-C
-
Measures incandescent, fluorescent, metal halide, high-pressure sodium and halogen lampoutput. Color and cosine-corrected for enhanced accuracy. Measures up to 50,000 lux. Peak and data hold means no lost measurements. Accessories included: (1) 9V battery and carrying case. Lifetime Limited Warranty.
-
Product
Black Body Calibration Sources
-
Nagman Instruments & Electronics Pvt. Ltd
Black body calibration sources by Nagman are used to calibrate infrared temperature devices that are used to measure temperature. Infrared devices can measure extreme temperatures that are very high as well as very low. They allow to measure temperature from a safe distance from the device that is heated or cooled. Calibrating the infrared temperature devices at regular intervals is very important to ensure an accurate and error free measurement. Black body calibration sources allow for an accurate calibration of the temperature devices.
-
Product
Precision AC/DC Current Shunt
1625A
-
The BLI 1625A is a multiranging, high accuracy, active current shunt, for use in making NIST traceable measurements of currents from 10 microamperes to 100 Amperes. Very high measurement stability has been achieved in our shunt design by using special alloys, compensated by a proprietary Ballantine process to minimize temperature coefficient effects.
-
Product
Tidal Current Flow Meter
-
KDL’s tidal current flow meter gives you the ability to monitor the speed and direction of tidal currents . Tidal flow speed information is extremely important to aid shipping movements such as berthing.
-
Product
AC and DC Current or Voltage Transducers
VT7 AND VT8 Series
-
The Model VT7 Series dc voltage transducer produces an output which is directly proportional to the input from dc to 10kHz. It functions as a millivolt dc shunt or a high voltage isolator to 1000V
-
Product
Fully Automatic Eddy Current Crack Test System
ROTO-SCAN
-
Foerster Instruments, Incorporated
The fully automatic crack test system ROTO-SCAN was specially developed for the testing of rings. The mechanical equipment has been developed for the gentlest possible handling of the test pieces and features a compact and low-maintenance design. The test probes seamlessly scan the inner and outer contours of the test pieces, thus ensuring 100 % testing of the rings.
-
Product
Digital Eddy Current Displacement Sensor
ZET 7140-S
-
A digital eddy current sensor consists of a primary transducer (eddy current probe) and the ZET 7140-S measuring unit.
-
Product
Pulse Current Generator Multi-Pulse Generator
-
Shanghai Guantu Technology Co., Ltd.
What is the difference between ordinary current and pulse current?The difference between ordinary current and pulse current: ordinary current is continuous and uninterrupted current.Pulse current is a current whose direction does not change and whose intensity changes periodically with time.
-
Product
Digital Volt Or Current Meter
CS1/CS2-VA
-
Measuring Voltage or Current for DC / AC / TRMS Accuracy: DC: +/-0.04% or AC: +/-0.1%; Display range: -19999~29999 User function, Easily programmable via the front panel. 1 relay, 1 Analogue output or RS 485 communication port in option with flexible functions. CE approved
-
Product
12-Ch SPST 4A-250VAC 24VDC High Current Power Switching
YAV90PIN
Switch Module
The YAV90PIN board is designed to cover the need to control the available power supplies in a test system to the device under test. A VPC 90 series connector is used as interface with the fixture, guaranteeing more than 20.000 mating cycles. Two connector contacts per relay contact are used.