Product
PXI 2A Multiplexer, 4-Bank, 4-Channel 8-Pole
40-614-009
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI High Density Multiplexer, 2-Bank, 40-Channel, 1-Pole
40-615A-017
Multiplexer Module
The 40-615A-017 is a 2-bank, 40-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
2-port Battery Portable Passive Intermodulation Analyzer - iXA Series
iXA
-
The Kaelus iXA Series Passive Intermodulation (PIM) analyzer is a dual-port, battery powered PIM Test Analyzer. It supports multiple test scenarios such as testing at the top of the tower, the base of the tower, rooftop, in-building for DAS systems and external PIM Finding.No other PIM tester has ever been integrated to this level! The iXA includes a network of electronic switches to change from one-port to two-port measurement seamlessly. In addition, with integrated Range-to-Fault (RTF) on each port, the user can first troubleshoot the system for internal PIM. Then, without reconnection, the user can progress with the external PIM process, making the entire process much more efficient.With integrated RTF on each port, the user can collect four times more range-to-fault data than the standard 1-port PIM Finder solution. Thus, the user can easily locate and swiftly eliminate the strongest PIM source.
-
Product
PXI/PXIe Very High Density Multiplexer, 198-Channel, 1-Pole
40-675B-002-198/1
Multiplexer Module
The 40-675B-002-198/1 (PXI) and the 42-675B-002-198/1 (PXIe) are 198-channel, 1-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems.
-
Product
High-Speed Data Acquisition System
TMX
-
Astro-Med Recorders Maintain their Position as the Easiest to Use Data Acquisition Systems on the Market. Stop fumbling with those awkward buttons or knobs and complicated configurations! The TMX features an exclusive full-color 17" advanced touch screen technology, as well as pre-defined set up options, eliminating the need for training. With the TMX, you will be an expert in no time!
-
Product
PXI High Density Multiplexer, 8-Bank, 16-Channel, 1-Pole
40-610A-001
Multiplexer Module
The 40-610A-001 is a 8-bank, 16-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI High Density Mux 10 Channel 8 Pole
40-670A-021-10/8
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
Dual 16x2 1-Pole High-Density PXI Matrix Module
40-520-501
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
Intel 80486 DX4
MS 1502
-
- ATE- Data Acquisition System- Process Control Industry- Industrial Automation
-
Product
Data Acquisition System
DataNet
-
High-end 16-bit intelligent data acquisition system, utilizing ZigBee wireless telemetry protocol, with 4 inputs for direct measurement.
-
Product
PXI Very High Density Multiplexer, 49-Channel 2pole
40-670C-021-49/2
Multiplexer Module
The 40-670C-021-49/2 is a 49-channel, 2-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected.In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
Temperature Sensor
ITS-7025
-
The ITS-7025 Temperature Sensor was developed to monitor the temperature of liquid-cooled klystron amplifiers. The sensor is designed to clamp directly to the cooling pipe and provide an analog voltage output from 0 to 10 VDC corresponding to 0 to 100 degC with 2 degC accuracy. Two analog outputs are provided; one for connection to a remote data acquisition system, and a second for local service monitoring. A single +28 VDC (other voltages available) powers the sensor which draws less than 100 uA.
-
Product
PXI Single 44 x 4 Matrix 1 Pole Screened
40-523-021-S
Matrix Switch Module
The 40-523 module is configured as a 44x4 high density matrix with available reedrelay formats of 1-pole, 2-pole and 1-pole screened. The screened version is suitablefor switching signals up to 50MHz. Model 40-524 is a similar matrix, available insingle pole 46x4 format. Typical applications include signal routing in FunctionalATE and data acquisition systems. These PXI matrix cards are constructed using highreliability Ruthenium Electro-Plated Reed Relays, offering >10e8 operations togive maximum switching confidence with long life and stable contact resistance.
-
Product
PXI High Density Multiplexer, 5-Bank, 32-Channel, 1-Pole
40-615A-005
Multiplexer Module
The 40-615A-005 is a 5-bank, 32-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
Data Acquisition System - 3U 5-Slot
DAQ-35CP0G
Data Acquisition Module
is a preconfigured rugged system ideally suited to support a multitude of military/aerospace data acquisition applications that require "SBC-less" remote Gig-E command and control of high-density, multichannel programmable ARINC 429/575; Dual-Redundant, Quad Channel MIL-STD-1553B; CANBus (CAN 2.0 A&B or J1939); A/D Conversion; RTD Measurement; RS-232/422/485 Serial Communications; Thermocouple Measurement; Discrete I/O; Differential Transceiver and Dual-Port Gig-E Ethernet.
-
Product
Single 32x8 1-Pole High-Density PXI Matrix Module
40-520-201
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
External Measuring Systems
LAN, USB
-
An alternative for measuring cards integrated in a PC are external data acquisition systems from BMCM. In this case, sampled data are transmitted to the PC via the USB interface or the LAN network - perfect for mobile applications!
-
Product
PXI Multiplexer Single 24 Ch 2 Pole
40-632-021-24/2
Multiplexer Module
This series of general purpose multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 68-pin connector. Available reed relay formats are 1-pole, 2-pole, 4-pole and 1-pole screened.
-
Product
PXI 12x4 Matrix, 1 Pole Screened
40-510-021-S
Matrix Switch Module
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
Product
PXI High Density Multiplexer, 1-Bank, 64-Channel, 1-Pole
40-610A-012
Multiplexer Module
The 40-610A-012 is a 1-bank, 64-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
SIRIUS Waterproof
-
SIRIUS Waterproof - Rugged and Modular Data Acquisition SystemExtremely rugged (IP67 degree of protection) and fully isolated rugged data acquisition system for the most demanding testing in harsh environments. High-precision, high-dynamic, and high-bandwidth for all types of analog signals from IEPE to strain gages.
-
Product
PXI Very High Density Multiplexer, 10-Channel 8-pole
40-670C-021-10/8
Multiplexer Module
The 40-670C-021-10/8 is a 10-channel, 8-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI Dual 32x4 Matrix 2-Pole Switching
40-534A-022
Matrix Switch Module
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.
-
Product
PXI 2 Amp Multiplexer, Dual 16-Channel, 2-Pole
40-635A-006
Multiplexer Module
The 40-635A-006 is a dual 16-channel, 2-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
Data Acquisition System
DAQ
Data Acquisition Module
Data Acquisition (DAQ) systems are used to collect information for the purpose of documenting or analyzing an electrical or physical phenomenon, for example: temperature or pressure. They serve as a focal point in tying a wide variety of sensors together that indicate temperature, flow, level or pressure. The sensors convert a physical occurrence into a measurable electrical signal, which can be factored into command and control decisions. These high-speed DAQ systems feature different analog and digital input and output modules that can be used with a wide range of signal types including 4-20 mA current, thermocouples, and RTDs.
-
Product
Instrument Grade Data Sensor
WISER 8000
-
TECAT Performance Systems, LLC
The TECAT WISER Model 8000 dual strain measurement and monitoring system is a wireless data acquisition system for measuring two external strain channels at high data rates up to 8kHz. The small, light, power-efficient, and non-invasive design enables strain measurements in a wide range of applications. With dual external sensor inputs two Micro-Measurements strain gauge bridges can be measured by a single system, for example to measure both thrust and torque loads simultaneously.The Model 8000 has a long range data transmission of >1,000 meters with up to +/- 0.025% FSR sensitivity for remote measurements. After initial setup using the WISER software interface, the system can be wired directly to your DAQ system, for seamless data collection.
-
Product
Precision Voltage to Current Converter
64-VCC
-
The 64-VCC precisely converts voltage to current. The unit can be placed in-line with a data acquisition system to achieve outstanding conversion accuracy for precise movements in valves or motors. The unit includes a unique current feedback measurement output to precisely monitor actual current in critical applications.
-
Product
PXI Single 64x4 Matrix 2-Pole Switching
40-533A-022
Matrix Switch Module
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109 operations to give maximum switching confidence with long life and stable contact resistance.
-
Product
Instrumented Pendulum Impact Testing System
JB(INSTRUMENTED)
-
Jinan Testing Equipment IE Corporation
JB-450I/750I Instrumented Pendulum Impact Testing Machine is equipped with high precision instrumented strain-gauged striking edge & high-speed data acquisition system. This instrumented test system can measure the force of a test specimen during an impact event. Then, the instrumented test data can be used to calculate the energy absorbed by the test specimen. In addition, the crack initiation and arrest loads can be used in fracture mechanical models.
-
Product
Dual 8x8 1-Pole High-Density PXI Matrix Module
40-520-207
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.