Product
Infrared Calibration
-
Optical pyrometers can be calibrated from 800 to 2300C using NIST certified ribbon filament lamps and temperatures up to 3500C using a graphite arc furnace. Infrared thermometers can be calibrated from -30C to 2300C utilizing state-of-the-art blackbody sources and transfer standards.
-
Product
Acoustic Emission Instruments
-
The Acoustic Emission NDT technique is based on the detection and conversion of high frequency elastic waves into electrical signals.
-
Product
Electrical Calibration
-
Process Instruments calibrates a wide variety of test and measurement equipment. All calibration procedures are written, and most are automated, insuring reliability and repeatability of measurements.
-
Product
Waveguide Calibration Kits
-
Designed to provide accurate calibration of vector network analyzers (VNAs) that are used for measurements in standard rectangular waveguide from 2.6 to 50 GHz (WR284–WR22).
-
Product
Chemical Calibration
-
Trescal provides full Chemical Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Chemical Calibration services can be delivered at your site or at our lab. Accreditations for our chemical calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Dual-Channel Weatherproof Acoustic Recorder
SM4
-
The 4th generation Song Meter SM4 is a compact, weatherproof, dual-channel acoustic recorder capable of capturing large amounts of data from wildlife such as birds, frogs and aquatic life.
-
Product
Calibration Solutions
-
Calibration or buffer solution lets you calibrate any pH tester to ensure accuracy. Choose from pH 4, 7 or 10. Calibration solution helps you achieve the accuracy that's critical for measuring pH in wastewater, stormwater and process liquids. Sper Scientific offers both liquid and buffer pouches, which are ideal for field use.
-
Product
PLTS Advanced Calibration
N19305B
-
PLTS N19305B extends the N19301B base product to perform advanced calibration techniques such as Automatic Fixture Removal (AFR)
-
Product
N1.2 Calibration Kit
-
N1.2 Calibration Kit, Frequency Range: up to 1.5 GHz, Impedance: 50 Ohm Connector Type: N-type
-
Product
Calibration
-
During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.
-
Product
Portable Temperature Calibrators
-
Portable temperature calibrators (dry-well calibrators) are electronic controllers which automatically, quickly and dryly supply a temperature. Due to the high reliability, accuracy and simple operation, portable temperature calibrators are particularly suitable as a factory/working standard for the automatic testing and/or calibration of temperature measuring instruments of all types. A major advantage is offered by the large sleeve diameters and the fast, stable temperature control, since, as a result of these characteristics, the time for calibration can be used very effectively.
-
Product
Calibrated Leak Standards
-
LeakMaster is a leader in the industry when it comes to the manufacturing of calibrated leak standards (calibrated leak orifices). Each leak standard is meticulously manufactured to a specific leak or flow rate at a predetermined pressure. The purpose of each leak standard is to teach, or calibrate a leak test program, and allow the leak test instrument to memorize the characteristics of a leaking part. These leaks are also introduced into production parts to simulate a “leaking or failed” part condition. LeakMaster supplies a calibrated leak standard with every leak test instrument, and provides recertification services for all of their leak standards
-
Product
Ice Point Calibrators
-
These ice point calibrators are designed to accurately calibrate probes at the freezing point of water. These devices have multiple thermowells to calibrate multiple sensors simultaneously.
-
Product
Industrial Pressure Calibrator
2271A
-
The Fluke Calibration 2271A Industrial Pressure Calibrator provides a complete, automated solution for calibrating a wide variety of pressure gauges and sensors. Thanks to its modular design, it can be configured to meet different needs and budgets, and expanded to cover a broad workload. The 2271A is ideal for calibration laboratories starting out in pressure calibration because it offers wide pressure measurement capabilities in a single instrument. Everything you need for calibrating pressure is included; just connect supply pressure. And your investment will stand the test of time: as your workload grows and changes, the 2271A can grow and change too. Just add measurement modules.
-
Product
Force Calibrating Machines
-
Morehouse Instrument Company Inc.
Morehouse Universal Calibrating Machines (UCM) are an easy to use, cost-effective, hydraulic force calibration system that lasts for generations. UCMs built in the 1950s are still operating today! The UCM can be used to calibrate both tension and compression instruments in accordance with ASTM E74, ISO 376, and other internationally recognized force standards.
-
Product
Acoustical Measurement System
MLSSA
-
MLSSA is the industry standard loudspeaker measurement system and the MLSSA Speaker Parameter Option (SPO) is the industry standard for measuring the Thiele-Small parameters of loudspeaker drivers. MLSSA and SPO both include QC (Quality Control) PASS/FAIL functions for high-speed automated production line testing of loudspeakers and drivers.
-
Product
Calibration & Demag.
Model 990A/990C
-
The Model 990 Series Magnetreaters® are highly accurate, pulse type, ringing demagnetizers (also called treaters) for the controlled stabilization of permanent magnets and permanent magnet assemblies. Regardless of line voltage stability, they provide a controlled output through continuous pulse amplitude regulation. Treating voltage is variable from 0 to 600 VDC. Additional energy can be added to the Model 990 Series by interconnecting a Model 992 Energy Booster. The energy level is increased from 18 to 36 watt-seconds. With this option, treating coils will produce higher demagnetizing fields and lower ringing frequencies, which can provide greater field penetration in some applications.
-
Product
Multi-Cal Pressure Calibrator
MC
-
Series MC Portable Multi-Cal Pressure Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility.
-
Product
Calibration Kit
S911T
-
*S911T Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: 3.5 mm female.
-
Product
Pressure Calibration
-
We make pressure calibration easy! All you have to do is hand us over your gauge or meter! We’ll look after the rest, half inch, quarter inch, brass or steel fitting, we have the adapters to make it work.
-
Product
Volume Calibration
-
Trescal provides full Volume Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Volume Calibration services can be delivered at your site or at our lab. Accreditations for our volume calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Pyrometer Calibration
-
Tempsens offers calibration of Non contact temperature sensors i.e. Infrared pyrometers traeceble to both national and international standards. Infrared thermometers can be calibrated at our NABL accredited laboratory, from 0ºC to 2900ºC utilizing state-of-the-art blackbody sources.
-
Product
Loop Calibrator
6500 LC
-
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
Product
Energy Meter Calibration
-
Beijing GFUVE Electronics Co.,Ltd.
The process of verifying the measurement accuracy and working status of the energy meter through the actual test.
-
Product
Electrical Calibration
-
Beijing GFUVE Electronics Co.,Ltd.
Checking condition , performance , sensitivity and accuracy of any electrical device.
-
Product
Audio and Acoustic Functional Test Solution
Functional Test
With the growing popularity of Internet of Things devices worldwide, many electrical products are adopting voice commands as their user interface. This means that acoustic and audio test challenges are likely to impact more products than ever before. Test teams must meet extended test coverage requirements to ensure product quality while maintaining throughput and operational efficiency. For a solution to meet these sorts of demands, it must:
-
Product
Integrated USBL Acoustic Tracking and Communication Systems
-
The TrackLink systems are the world's best selling USBL acoustic tracking systems with fully integrated high speed acoustic communication capability. Capitalizing on its benchmark Broadband Acoustic Spread Spectrum (BASS) technologies, LinkQuest provides the end users with solutions for underwater tracking and communication at sharply reduced cost and increased robustness. An extensive line of models are available to suit the users' specification and budget constraint.
-
Product
Traditional Handheld Refractometer Calibration
BRX & DOT Series
-
Two-point NIST Traceable Certified Calibration for the following refractometers: BRX 15, DOT3, DOT4, and other BRX prefix refractometers.
-
Product
Precigrader: Acoustic MSR System
-
Precigrader is an acoustic on-line strength grading system. The system is installed in more than 150 mills. It is used to determine common commercial grades in North America, including 1650 and 2100. A spring-loaded impact mechanism strikes the lumber as it passes. The resulting vibration is captured by microphones to determine the appropriate MSR grade.